SP-6890 gas chromatograph
1. The machine has pioneered the function of gas cut-off protection (automatic alarm), which maximizes the protection of chromatographic columns and T
Product details

1. The machine has pioneered a gas cut-off protection function (automatic alarm) to maximize the protection of the chromatography

The column and TCD tungsten wire are not damaged;

2. Adopting a brand new humanized and dual CPU design, with extreme temperature overload protection

Function;

3. It has a wide range of fault self diagnosis functions, which can help users easily identify faults

Obstacle orientation;

4. It has a five stage program heating function Intelligent rear door opening system to cool down the column chamber

Very fast speed;

5. The basic configuration of the machine is a dual hydrogen flame detector, which can be equipped with a single FID amplifier or dual

FID amplifier In addition, there is a large reserved expansion space, and TCD can be optionally selected at any time

FID, NPD, ECD detectors, as well as gas injectors, converters, etc. should

The host can install four types of detectors simultaneously and can control temperature separately;

6. It has six independent temperature control zones. Each vaporization chamber, detection chamber, and amplifier

Adopting modular design. Installation and replacement are very convenient;

7. The highly stable and sensitive microcurrent amplification technology significantly improves the detection limit of FID;

8. After selection, this machine can simultaneously install small-diameter capillary tubes and large-diameter capillary columns

And packed columns, various chromatographic columns are easy and reliable to install, among which small caliber capillary

The column specific vaporization chamber has split/non split, diaphragm blowing, and tail blowing systems.

Column box temperature:

Room temperature+5 ℃~400 ℃ Accuracy: ± 0.1 ℃;

Five stage program temperature rise, with each stage maintaining a constant temperature for 0-999.0 minutes.

Increment of 0.1 ℃, with a 0.1 ℃ increase in temperature;


● Detector

Hydrogen Flame Detector (FID)

Detection limit: D ≤ 8 × 10-12G/sec (n-hexadecane/isooctane)

Linear range: 107

Baseline drift: ≤ 1×10-14A/30min

Noise: 5 × 10-14A


Thermal conductivity detector (TCD)

Sensitivity: s ≥ 4000mv. ml/mg (benzene/toluene)

Baseline drift: ≤ 0.05mv/30min

Noise: ≤ 0.015mv


Electron Capture Detector (ECD)

Detection limit: D ≤ 1 × 10-13G/ml (r-666/iso octane)

Base flow: Io ≥ l × 10-9A

Baseline drift: 0.02mv/30min

Noise: ≤ 0.01mv

Linear range:> ten4

Radiation source: Ni63


Flame photometric detector (FPD)

Detection limit: D (p) ≤ 2 × 10-12G/sec (1605/ethanol)

D(s)≤5×10-11G/sec (thiophene/n-hexane)

Baseline drift: ≤ 3×10-13A/30min

Noise: ≤ 2×10-12A


Nitrogen phosphorus detector (NPD)

Detection limit: D(N)≤5×10-12G/s (azobenzene/isooctane)

D(p)≤5×10-12G/s (Malathion/Isooctane)

Baseline drift: ≤ 2×10-12A/30min

Noise: ≤ 2×10-12A