Product Introduction:
JB-5C profile roughness tester is a precision measuring instrument that combines two into one, widely used in industries such as mechanical processing, automotive, bearings, machine tools, molds, precision hardware, optical processing, etc. The JB-5C contour roughness tester drive box provides high-precision linear reference rails with different specifications of travel of 100, 120, and 150 millimeters. The sensor moves in a straight line along the rail, and the displacement is collected using a precision grating displacement sensor. Thus, the X coordinate measurement unit is established, and differential inductance sensors with two specifications from 10mm to 20mm are used in the Z-axis direction. The drive box can be horizontally adjusted by ± 10 degrees through the horizontal adjustment knob, and can be moved horizontally and vertically through the operation keys or software interface of the control box. The sampling shape can be enlarged proportionally at will. The JB-5C contour roughness tester comes with a computer and dedicated measurement software. The measurement software under the WINDOWS XP operating system is intuitive and convenient to operate, with rich functions, high accuracy, good stability, and easy printing output and file saving.
It can measure the roughness and contour shape parameters of various precision mechanical parts. The fitting method can be used to evaluate radius, angle processing, circle processing, point and line processing, as well as the angle and distance between the centers of two circles. Thus, shape parameters such as straightness, convexity, groove center distance, inclination, groove depth, groove width, groove edge distance, groove center distance vertical distance, horizontal distance, and steps can be measured.
The JB-5C contour roughness tester can now be compared with imported foreign instruments in terms of performance, and all indicators have reached international standards. The instrument meets the requirements of national standards GB/T3505-2000, GB/T6062-2001, GB/T10610-1998, as well as international standards ISO5436, ISO11562, and ISO4287. Please refer to the technical parameters for detailed indicators.
Technical specifications:
| model | JB-5C |
| roughness measurement | |
| Testing Parameters | Ra,Rz,Rt,RS,RSm,Rp,Rv,Rmax,Rq,D,Pt, Lr, Ln, and Rmr (Tp) curves, etc |
| Magnification of roughness contour graphics | 10, 20, 50, 100, 200, 500, 1000, 2000, 5000, 10000, 500, 000, 200, 000, 500000 or automatic |
| Range of roughness measurement | Ra 0.01-10 µ m or above |
| Sampling length | L: 0.08, 0.25, 0.8, 2.5, 8 mm or any other setting |
| evaluation length | Ln: 1L, 2L, 3L, 4L, 5L selectable |
| Instrument evaluation sampling | 100000 points |
| resolution | 0.001 µm |
| Indication error | ± (5 %+4nm) |
| Measurement repeatability | ± 3 % |
| Measure the maximum height of the workpiece | 370mm |
| Sensors can measure | Surface roughness of various parts such as flat, inclined, inner hole surface, outer cylindrical surface, deep groove surface, circular arc surface, spherical surface, etc |
| Natural diamond contact needle | Standard type, height: 12mm Small hole type: 4mm Needle radius: 2 µ m, static pressure of needle 0.004N, tip angle: 60 degrees |
| Sliding speed of the drive box | 2mm/sec |
| Automatic lifting Auto | |
| movement speed | 0.5 mm/sec,1mm/sec |
| Linear region | Vertical 640 um |
| Steps and Pt measurement range | 1mm |
| Axial measurement range | 100mm |
| Figure | Direct contour, filtered contour |
| Magnification ratio of X and Y for contour shapes X、Y |
1-500 times click to enlarge |
| filter | ISO 2CR filter |
| Small hole measurement range | ≥ Ø5 mm |
| x-y table | Rotation angle ± 10 degrees X-Y movement range 15 mm |
| Dimensions of the inner and outer rings of the bearing | The maximum outer diameter of the inner ring is 280mm Thickness 160mm The minimum aperture of the outer ring is 15mm |
| Printing paper specifications | A4 paper |
| operating system | WinXP |
| Contour measurement range | |
| Measurement range: | X:100mm Z:10mm |
| Shape measurement function |
Elements: point, line, top, valley, intersection point, junction point, centerline. Analysis: Coordinate difference, distance, angle, radius, contour degree, etc. |
| Sensor range: | 1mm (roughness), 10mm (contour) |
| Magnification of Shape and Shape Shapes | 1,2,3,4,5,10,20,50,100,120,150,200,250,300,350,400,450,500 |
| Range to resolution ratio | 65,536:1 |
| Radius error | 0.1%-1.0% |
| Axial measurement range | 100mm |
| Sampling rate | 0.5mm/s, 1mm/s |
| movement speed | 2mm/second |
| Up, down, left, right movement range: | X:100mm Z: 370mm |
| Pin length | 18mm and 6.5mm |
| Needle tip radius | 10μm |
| Needle tip angle | Long needle 16 degrees, short needle 30 degrees |
| dynamometry | 0.01-0.02N |
| Printing paper specifications | A4 paper |
| operating system | Win98/2000/XP |
| Optional parts | Optional measurement of workpiece maximum height: 500mm |
| Standard accessories, attachments | Main unit of contour roughness meter, support column and marble bottom, controller, driving device sensor, adjustable worktable, angle adjustment worktable, V-shaped block, fixture, standard type contact pin, small hole type contact pin, contour contact pin, roughness template, contour standard ball computer printer, user manual |
| Instrument power supply | 220 VAC ±10%, 50Hz |
| Marble workbench size | 700mm × 400mm × 100mm Weight: 150kg |
| Gross weight of the instrument | 200Kg |