Xi'an Huaerwei Instrument Co., Ltd
Home>Products>Rail type temperature transmitter
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    13909219277
  • Address
    No. 76, North Exit of Labor Road, Xi'an City
Contact Now
Rail type temperature transmitter
● Can be equipped with LCD/LED display header via HART protocol
Product details

• Can be equipped with LCD/LED display header
• Configure using PDA or PC via HART protocol
USB direct communication configuration
There are more types of thermal resistance inputs, up to 11, with a resistance of up to 10K Ω and a voltage of -100~2000mV
Thermocouple input types cover a wide range
High precision, built-in cold end compensation
• Electrical isolation 2KV
Basic Parameters
Output signal: Analog 4-20mA
Supply voltage: U=7.5V~45V
Load: Max. (V power supply -7.5V)/0.0208A (current output)
Alarm current: Below the measurement upper limit, the output drops to 3.8mA
Above the measurement limit, the output rises to 20.8mA
Sensor damage; Sensor open circuit (excluding thermocouple TC), output is 3.8mA
Input current: ≤ 3.8mA
Current limit: ≤ 20.8mA
Environmental temperature: -40 to+85 ℃
Storage temperature: -40 to+100 ℃
Protection level: IP00, IP66 (installation)
Cold end compensation: Built in cold end compensation
Operation method: Adjust online through PC programming or manual controller
Accuracy level: ≤ 0.2K or 0.08%
Electrical isolation: 2KV
Measurement variables: temperature (temperature linear transfer), resistance, and voltage
Measurement range: The variation of the transmitter's measurement range depends on the sensor connection mode and input signal
Voltage influence: negligible
Environmental temperature impact: negligible (temperature drift)
Condensation: allowed
Seismic resistance: 4g/2-150Hz
Installation angle: unlimited
4-20mA two-wire output
Suitable for various types of thermistor sensorsPt100, Pt1000, Cu50, Cu100 type, etc
DIN35rail-mounted installation
·type number:MTRS1
·
Output signal:4-20mATwo line system (please specify for special outputs)
·Supply voltage:24V DC12~30V
·Measurement range: User customized
·Accuracy level:±0.5%FS ±0.2%FS ±0.1%FS
·
Ambient temperature-20~80
·Functional features: Linear compensation, sensor disconnection alarm function
·Scope of application: Suitable for various types of thermistor sensorsPt100Pt1000Cu50Cu100Type, etc
·Overall dimensions:94×24mm H41mm
· DIN35rail-mounted installation
4-20mA output
Suitable for various types of thermocouple temperature sensorsK. S, E, B, etc
DIN35 rail installation
·type number:MTCS1
·
Output signal:4-20mAtwo-wire system
·Supply voltage:24V DC12~30V)(Please specify special outputs)
·Measurement range: User customized
·Accuracy level:±0.5%FS ±0.3%FS
·
Ambient temperature-20~80
·Functional features: automatic cold end compensation, sensor disconnection alarm function
·Scope of application: Suitable for various types of thermocouple sensorsKSEBwait
·Overall dimensions:94×24mm H41mm
· DIN35rail-mounted installation


Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!