Shanghai Yuanben Magnetoelectric Technology Co., Ltd
Home>Products>RFID高频读写器(High frequency RFID reader with RF-1232-114B)
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
  • Address
    6133 Huyi Road, Jiading District, Shanghai
Contact Now
RFID高频读写器(High frequency RFID reader with RF-1232-114B)
RFID高频读写器(High frequency RFID reader with RF-1232-114B)
Product details

High frequency RFID reader (13.56 MHz)

P/N:RFH-1332-114B




1. Overview

RFID (Radio Frequency Identification) RH-1332-114B is a non-contact high-frequency RFID reader specifically designed for embedded applications such as AGV address reading or proximity control and other industrial applications. It can work in various harsh environments. The RFID reader has anti-collision function and operates at a frequency of 13.56MHz.

2. Main features

Compliant with ISO 15693 protocol and ISO/IEC 18000-3 protocol; ISO 14443A protocol.

Support NXP I. The code SLI and other tags comply with the ISO15693 protocol.

Supports reading and writing, with no data misreading.

RS232 with cable (1.0 meter long), RS485, and Ethernet (TCP/IP) can be selected.

Built in RFID antenna (integrated design of reader/writer and antenna)

Read and write distance 70-90mm (industrial environment), read and write time less than 20ms/8-bit.

Good packaging IP65, PBT engineering material suitable for industrial environment applications


3. Application

AGV、 Address reading or proximity control for forklift and industrial production line material identification applications.

4. Technical Data Sheet

operating frequency

13.56MHz

Working Voltage

10-30Vdc

operating current

<0.2A

quality standard

ISO/IEC 15693and 14443A

meet the standard

ISO18000-3 mode

. Large reading distance

70-90mm

Reading Time

20ms/8 bit

radiated power

2W

interface

RS485TCP/IPoption

instruction

2 LED (Red LED for power, Green LED for working )

Operating Temperature

-20~+70

Storage temperature

-20~+85

Operating Humidity

95%

cable

5 core shield (800mm) or (M12 option)

Shell color

Green Housing

housing material

PBT+ABS

size

As attached drawing

IP Class

IP65 Industry Environment

6. Wiring Diagram

Cable number

ccolor

Pin configure

2

Brown

Vin 9-30vdc

4

Blue

GND

1

White

TX

5

Grey

RX

113.jpg

7. RFID sensors in host communication packet format

This data message format is used for communication between RFID (HF) sensors and hosts (controllers). The host sends commands (downstream), and the RFID sensor responds (upstream). The baud rate of the communication port is 9600, the data is 8 bits, there is no odd parity, and the stop bit is 1 bit.


command format

Initial frame

01

data length

Data1

Data2

Data N

Verification (CAL)

End frame

FD

Data length: the length of data 1 to data N (=N);

Checksum (CAL): From the length of the data to the sum of N (N+1 numbers), take the lower 8 bits.

Note: The data is hexadecimal numbers in the table

1Starttoreadtag

01

02

42

47

8B

FD

2Stop reading tag

01

02

45

44

8B

FD

3Reading 15693 tag data

01

03

54

52

Block number

0-1bit

CAL

FD

Respond

01

04

XX

XX

XX

XX

CAL

FD

Where from3 to 6 bytes are read data (4 bytes).

4Writing 15693 tag data

01

07

54

57

Block number0-1bit

XX

XX

XX

XX

CAL

FD

Where from 6 to 9 bytes are written data (4 bytes)

Respond (success)

01

04

53

55

43

43

32

FD

5Reading Mifare tag dataS70 card

01

03

4D

52

Block number

00-3F

CAL

FD

Respond(success)

01

10

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

CAL

FD

Where from 3 to 18 bytes are read data(16 bytes).

6Writingmifare tag dataS70 card

01

13

4D

57

Block number

(00-3F)

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

CAL

FD

Where from 6 to 21 bytes are written data (16 bytes).

Respondsuccess

01

04

53

55

43

43

32

FD

Instructions

1. The RFID sensor automatically reads the card when it is opened.

2. When the tag is in the reading area, the RFID sensor automatically reads the data stored in the tag.

3. The RFID sensor automatically stops reading the card after receiving the stop reading command, and can restart the card reading after receiving the read command.

4. When using the Mifare tag, blocks cannot be read or written using block numbers 3+4+n (n=0, 1, 2...), in other words, blocks cannot be read or written using block numbers 3, 7, 11....


Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!