REL Cone Plate Viscometer
The well-known viscometer in the copper-clad laminate industry has been serving the copper-clad laminate industry for decades
Product details

A well-known viscometer in the copper-clad laminate industry

For decades, we have been serving the copper-clad laminate industry and have gained recognition from a wide range of users,

Characteristic: The rotor is sturdy and durable!

Although there have been few technological changes in the past few decades, the all-new REL230 display screen has been upgraded, and the body color has been changed from traditional blue to gray white after the upgrade.

Technical specification sheet:

Rotational speed (rpm)

Rotor 5.86 11.7 23.4 46.9 60 93.7 120 187.5 375 750 900 Shear Rate

2P 0‐256 0‐128 0‐64 0‐32 0‐25 0‐16 0‐12 0‐8 0‐4 0‐2 0‐1.6 80‐10,000 sec‐1

5P 0‐640 0‐320 0‐160 0‐80 0‐64 0‐40 0‐32 0‐20 0‐10 0‐5 0‐4 80‐10,000 sec‐1

10P 0‐1280 0‐640 0‐320 0‐160 0‐120 0‐80 0‐64 0‐40 0‐20 0‐10 0‐8 80‐10,000 sec‐1

20P 0‐2560 0‐1280 0‐640 0‐320 0‐250 0‐160 0‐128 0‐80 0‐40 0‐20 0‐16 20‐2,500 sec‐1

40P 0‐5160 0‐2560 0‐1280 0‐640 0‐500 0‐320 0‐250 0‐160 0‐80 0‐40 0‐32 20‐2,500 sec‐1

100P 0‐12800 0‐6400 0‐3200 0‐1600 0‐1200 0‐800 0‐600 0‐400 0‐200 0‐100 0‐80 20‐2,500 sec-1

Standard speed: 5.86, 11.7, 23.4, 46.9, 60, 93.7120187.5375750900 (11 gears)

Cone type: Cone is suitable for the above table range

Temperature range: Two temperature control systems are available, 10 ° C to 100 ° C and 25 ° C to 230 ° C, with adjustable temperature and a temperature resolution of 0.1 ° C.

Optional units: Celsius or Fahrenheit, RPM or sec-1, Pau or Pau seconds.

Characteristic: The piezoelectric reading is not affected by pollutants. Automatically reset to zero. Re calibrate the software through the PC interface.

Accuracy: ± 2% of full scale, confirmed using calibration standard oil

Power: 100-240VAC 50/60Hz single-phase 150W power.

Preheating: 10 minutes.

Digital display: board temperature, instrument range, reading.

PC interface: USB, Instrument range setting and control, with curve acquisition and storage