Coliynuclear radiationClassification List | |||||
Detectable radiation |
PRODUCT MODEL |
sensor |
range |
γX-ray sensitivity(Cs137,1µSv/h) |
characteristic |
portable | |||||
α、β |
R900 |
ZINC SULFIDE+plastic scintillator |
1Mcps |
-- |
Effective area1702 |
R700 |
ZINC SULFIDE+plastic scintillator |
1Mcps |
-- |
Effective area750px2 |
|
α、β、γ |
R500 |
Geiger counter |
1mSv/h |
7cps |
Large end window cover leather pipe Unable to distinguish the type of radiation |
910 |
Geiger counter |
1mSv/h |
2cps |
Small end window cover leather tube Unable to distinguish the type of radiation |
|
R800 |
CZTsemiconductor |
γ:10mSv/h β:1mSv/h |
7cps |
Simultaneously measuring andDistinguish displayα、βandγray |
|
γ |
RS10 Energy spectrum analyzer |
Φ50x50mmsodium iodide |
1mSv/h |
800cps |
Spectral analysis, energy resolution<> |
10x10x10mm3cadmium zinc telluride |
10mSv/h |
60cps |
Spectral analysis, energy resolution<> |
||
R100 |
GMcounter tube (After energy compensation) |
100mSv/h |
2cps |
persondoseAlarm device, energy range20keV~3MeV |
|
R750 |
Φ80x80mm plastic scintillator |
0.2mSv/h |
2000cps |
Environmental grade, ultra-high sensitivity Energy Range15keV~7MeV(±15%) |
|
RW10 |
φ35×35mmsodium iodide |
1.5mSv/h |
400cps |
100Continuous underwater work |
|
ION-H |
Radiation resistant scintillation sensor |
100Sv/h |
77cps |
High range measurement, optional range10Sv/h、 20Sv/h、50Sv/h、100Sv/h |
|
R700 |
Φ75x75mmplastic scintillator |
0.2mSv/h |
1500cps |
Environmental grade, high sensitivity |
|
R700 |
Φ30x30mmsodium iodide |
1mSv/h |
350cps |
answerγHigh radiation detection efficiency、1Quick response in seconds |
|
|
RC510 γX-ray imaging |
GAGGcrystal |
10mSv/h |
500cps |
High sensitivity sensor, encoding hole imaging technology Quickly identify and locate radiation sources |
|
Neutronsγ |
R60N |
10×10×10(mm3)Koley PatentHType sensor |
10mSv/h(Neutron) |
0.5cps(Cf-252 ) |
A single sensor can simultaneously detect neutrons andγray γPSRR≥1000:1 High sensitivity under the same volume3Hesensor20times |
20×20×20(mm3)Koley PatentHType sensor |
2.7cps(Cf-252 ) |
||||
Wall mountedR2000 | |||||
|
γ
|
GM30A |
Geiger counter |
1mSv/h |
2cps |
Small end window cover leather tube X、γEnergy response:50keV-3MeV |
CS30A |
Φ30x30mm plastic scintillator |
1mSv/h |
350cps |
1Quick response in seconds |
|
CS75 |
Φ75x75mmplastic scintillator |
0.2mSv/h |
1500cps |
Environmental grade High sensitivity |
|
Neutronsγ |
N10 |
10×10×10(mm3)Koley PatentHType sensor |
10mSv/h(neutron) |
0.5cps(Cf-252 ) |
A single sensor can simultaneously detect neutrons andγray γPSRR≥1000:1 High sensitivity under the same volume3Hesensor20times |
N20 |
20×20×20(mm3)Koley PatentHType sensor |
2.7cps(Cf-252 )
|
|||
R60NtypeNeutron gamma ray surveyinstrument
sketch
ColiyR60NtypeneutronGamma ray surveyinstrumentIt is aused forDetecting neutrons andγA new handheld radiation monitoring device for X-raysIt adoptsHType sensorIt is the world's first product that can be invested insendUsed, a single sensor can simultaneously measure and distinguish between neutrons andγradialNew Sensors.suchHType sensor with both6LiI(Eu)Scintillation crystal and3HeAdvantages of sensors:
lbe relative to6LiI(Eu)Scintillation crystal,HType sensoranswer137CSofγPSRRdo1000:1Far higher than6LiI(Eu)Scintillation crystalof20:1.
lbe relative to3HeSensors,HSensitivity of Type Sensor20Twice as much asOf equal volume3Hesensor.
HThe sensor is a cube shaped sensorstructure,4πError in angular responseExtremely small,High detection efficiency and fast response,γInhibition ratio up to1000:1The energy response range of neutrons0.025eV-16MeV,γThe energy response range50keV-1.5MeV.
R60NtypeNeutron gamma raytour gauginginstrumentIt's usingNeutron radiationentersensorThe amplitude of the voltage signal generated afterwards is much higher thanγThe amplitude of the voltage signal generated by radiationThe characteristics,combineAdopting Koley's unique circuit design and software algorithmAnd made,approvesimultaneous displayNeutrons andγradialradiation intensityThe radiometer can customize the alarm value range and hasmultipleMeasurementsdisplayReal time values, maximum values, minimum values, alarm thresholds, etc,At the same time, time-domain waveform diagrams can also be usedapparentThe X-rayradiationChanges in dose rate.R60NThe neutron gamma detector hasradiationCumulative doseRemote computer monitoringVarious practical functions such as automatic storage, data download and analysis.Products available in EuropeCECertification andISO9001Quality certification.
application
Monitoring of working areas involving neutron radiation, such as research reactors and particle accelerators
answerγRapid search for neutron radiation sources and application of radiation disposal environments
Nuclear facilities, nuclear regulation, and“Related sources”Radiation protection for enterprises and institutions
Patrol of personnel in hospital, oilfield logging, and industrial inspection control areas
The environmental monitoring department carries out official duties, and the disease control and health department responds to emergencies
Inspection and quarantine, customs, ports, border defense, and other nuclear and radiation counter-terrorism measures
Third party testing institutions and neutronsγRadiation Research Center
Personal neutron detection in nuclear power plants
Product Featuressexually
1. 4πOmnidirectional probe
2. Koley PatentHType sensor
3. Extremely highγInhibition ratio:>1000:1(Cs-137)
4. A single sensor can simultaneously detect neutrons andγray
5. Sensor with both3HeSensors and6LiI(Eu)Advantages of scintillation crystals
6. crystal size10×10×10(mm)neutron sensitivity:1µSv/h ≥0.5cps(Cf-252 )
7. crystal size20×20×20(mm)Neutron sensitivity:1µSv/h ≥2.7cps(Cf-252 )
8. Neutron energy response range0.025eV-16MeV;γEnergy response range50keV-1.5MeV
9. Touchscreen full-color graphical operating system with Chinese and English text interface
10. Provide large capacity data storage function, which can automatically and manually store data
11. Multiple display modes: standard display, waveform diagram, background removal display, multi probe display, etc
12. USBInterface, convenient for upper computer software to read, download and analyze real-time and historical measurement data
characteristic
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Technical Parameter
Probe model |
N10 |
N20 |
||
Detector crystal size |
10×10×10(mm3) |
20×20×20(mm3) |
||
Measure the type of radiation |
Neutron radiation |
γray |
Neutron radiation |
γray |
Dose rate range |
0.1μSv/h-10mSv/h |
0.01μSv/h-20mSv/h |
0.1μSv/h-10mSv/h |
0.01μSv/h-10mSv/h |
sensitivity |
1µSv/h≥0.5cps(Cf-252) |
|
1µSv/h≥2.7cps(Cf-252) |
|
Energy response range |
0.025eV-16MeV |
50keV-1.5MeV |
0.025eV-16MeV |
50keV-1.5MeV |
Cumulative dose |
0.1μSv-9999mSv |
0.01μSv-9999mSv |
0.1μSv-9999mSv |
0.01μSv-9999mSv |
counting rate |
1-20kcps |
|||
γPSRR |
>1000:1(Cs-137) |
|||
relative error |
≤±15%; Neutron(Cf-252) ≤±15%;γ(Cs-137) |
|||
sensor |
Koley PatentHType sensor |
|||
Probe directionality |
4πOmnidirectional |
|||
protection grade |
IP65 |
|||
Display |
3.2Inch color touchLCDdisplay |
|||
operating system |
Graphical interface operating systemDisplay interface in both Chinese and English |
|||
display mode |
Standard display, time-domain graph mode, multi ray mode, etc |
|||
Display units |
Sv/h,Gy/h,rem/h,Sv,cps,cpm,Bq/cm2 |
|||
Alarm method |
Sound and light alarm,Customizable alarm threshold within the range |
|||
alarm threshold |
Customizable |
|||
communication interface |
USB |
|||
size |
host238×95×42(mm) probeΦ70mm×180mm |
|||
weight |
host:350g |
|||
hostbattery |
rechargeable4500mAhlithium battery |
|||
|
Continuous battery usage time Power saving mode battery life |
>24hour >40hour |
|||
operation temperature |
-20ºC-+60ºC |
|||
storage temperature |
-30ºC-+70ºC |
|||
Expansion rod (optional) |
Length:153cm(Customizable) |
|||