Shenzhen Kerei Technology Development Co., Ltd
Home>Products>R500 Pro Surface Pollution Analyzer
R500 Pro Surface Pollution Analyzer
1. It can simultaneously detect alpha, beta, and gamma rays. 2. A new ultra-thin dual scintillation detector with patented design. 3. The detector thi
Product details

R500 ProSurface contaminationinstrument







sketch

R500 ProThe surface pollution meter is excellent due to itsshapeDesigned, obtainedAMTInnovative Design Award.Koley Company'sNewly developedR500 ProSurface pollution meter, usingCOLIYThe company's patented designnew typeultrathinDouble flash detector,Not using commonly used large volume photomultiplier tubes, resulting in a detector thickness of only16mmThe effective detection area is15cm2No need for inflation, greatly reducing the cost of useImproved usability.Optional cesium iodide gamma ray sensor and ultra-thin sensorDouble flash detectorPlaced on the same plane, so thatR500 ProSurface pollution meterCan simultaneously detect alpha, beta, and gamma rays. ultrathinDouble flash detectorusedThe thickness of the plastic scintillator is0.5mmIt greatly reduces the interference of gamma rays. The thickness of the aluminum film on the incident window is less than3μmYes, that's rightαThe absorption of radiation is only1MeV.The host adopts a color screen,Can simultaneously detect and display alpha, beta, and gamma ray values.

R500 ProSurface pollution meterCan quickly and reliably screen for radiation pollution,Directly detecting the surface of an objectαβLevel of radioactive surface contaminationandγ-rayHigh detection efficiency and fast response speedR500 ProSurface pollution meterFully meet the needs of usersHighly sensitive and multifunctional Requirements for ease of operation, etc.R500 ProSurface pollution meterErgonomically designed, the grip is easy to grip and the palm will not be contaminated. Equipped with correction factor function, customers can adjust the correction parameters themselves; The patented algorithm provides fast response and significantly improves sensitivity while maintaining stable background values. The anti saturation circuit can avoid interference from over range and electromagnetic waves, and has a safety calibration function that can prevent radiation exposure by calibration personnel.

application

R500 ProSurface pollution meter, applicable toEnvironmental protection, military, customs, health, nuclear industry, civil aviation, pharmaceuticals, nuclear power plants and other systems.

useMonitoring of radioactive environments, agricultural markets, workplaces, laboratories, hospitals, isotope production plants, nuclear material transportation, storage, and inspection sites, monitoring of human radioactive contamination levels, monitoring of goods radioactive contamination levels, food, and operationsMonitoring of radioactive contamination on surfaces such as surfaces, floors, walls, hands, and clothing.


Product characteristics

1. Can simultaneously detect alpha, beta, and gamma rays

2. Can display simultaneouslyα. Beta and gamma radiation values

3. Patent Designnew typeultrathinDouble flash detector

4. The thickness of the detector is only16mmNo need to inflate

5. Effective detection area15cm²

6. Probe adoptsZnSadd0.5mmThin plastic scintillator, no need to inflate

7. Aluminum film covering the entrance window, with a thickness less than3μm

8. Detecting background:αthoroughfare≤ 0.1cpsβthoroughfare≤ 15cps

9. Detection efficiency:α≥30%239Pu);β≥25%

10. Optional cesium iodide gamma ray sensor

11. Can be connected through the upper computer softwarePCImplement data storage, transmission, and analysis, etc


Technical Parameter

Measure the type of radiation

αβγandΧRadiation (withprotectSliding cover)

αβsurfacepollutionDetecting background

αthoroughfare≤ 0.1cpsβthoroughfare≤ 10cps

αβsurfacepollutiondetection efficiency

α≥30%239Pu);β≥25%

αβSurface contaminationDetection area

15cm2

αβSurface contaminationDetection sensor

Ultra thin dual flash detector(ZnScoating+Thin plastic scintillator

αβSurface contaminationDetection range

0-105cps

0105 Bq/cm2

γandΧraysensor

Cesium iodide crystal sensor

γandΧRadiation measurement range

0-105cps

0.01µSv/h-5000µSv/h

γandΧX-ray sensitivity

1µSv/h≥20cpsCs137

γandΧRadiation energy response

80keV -2MeV

display

black and white128x64LCDdisplay

Alarm

Sound and light alarm, alarm value can be freely set within the range

accuracy

±15%

communication interface

USB

Magnetic field influence

Magnetic field interference is noteffectmeasure

operation temperature

-20℃to+50℃

storage temperature

-20℃to+60

Working humidity

80%R.H(Non condensing)

Working atmospheric pressure

75kPa-110kPa

weight

450can

size

L300mmW90mmH40mm

power supply

3joint5namealkalinebatteryOr rechargeable battery

Certificate

CEISO9001

COLIYPatented ultra-thin dual flash sensor

After damage, it can be replaced as a whole to reduce user costs

1. Slide cover

Open the slide cover to detectαβγandΧray

Close the sliding cover, the sensor receives dual protection and can detectγandΧray


2.Telescopic rod

Telescopic pole, longest1.53Meter, can measure nuclear radiation from a distance, avoiding human injury

The front end angle of the telescopic rod can be adjusted freely

Real time remote transmission of numerical values to the computer for display and analysis

Upper computer software


Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!