Coliynuclear radiationClassification List | |||||
Detectable radiation |
PRODUCT MODEL |
sensor |
range |
γX-ray sensitivity(Cs137,1µSv/h) |
characteristic |
portable | |||||
α、β |
R900 |
ZINC SULFIDE+plastic scintillator |
1Mcps |
-- |
Effective area1702 |
R700 |
ZINC SULFIDE+plastic scintillator |
1Mcps |
-- |
Effective area750px2 |
|
α、β、γ |
R500 |
Geiger counter |
1mSv/h |
7cps |
Large end window cover leather pipe Unable to distinguish the type of radiation |
910 |
Geiger counter |
1mSv/h |
2cps |
Small end window cover leather tube Unable to distinguish the type of radiation |
|
R800 |
CZTsemiconductor |
γ:10mSv/h β:1mSv/h |
7cps |
Simultaneously measuring andDistinguish displayα、βandγray |
|
γ |
RS10 Energy spectrum analyzer |
Φ50x50mmsodium iodide |
1mSv/h |
800cps |
Spectral analysis, energy resolution<> |
10x10x10mm3cadmium zinc telluride |
10mSv/h |
60cps |
Spectral analysis, energy resolution<> |
||
R100 |
GMcounter tube (After energy compensation) |
100mSv/h |
2cps |
persondoseAlarm device, energy range20keV~3MeV |
|
R750 |
Φ80x80mm plastic scintillator |
0.2mSv/h |
2000cps |
Environmental grade, ultra-high sensitivity Energy Range15keV~7MeV(±15%) |
|
RW10 |
φ35×35mmsodium iodide |
1.5mSv/h |
400cps |
100Continuous underwater work |
|
ION-H |
Radiation resistant scintillation sensor |
100Sv/h |
77cps |
High range measurement, optional range10Sv/h、 20Sv/h、50Sv/h、100Sv/h |
|
R700 |
Φ75x75mmplastic scintillator |
0.2mSv/h |
1500cps |
Environmental grade, high sensitivity |
|
R700 |
Φ30x30mmsodium iodide |
1mSv/h |
350cps |
answerγHigh radiation detection efficiency、1Quick response in seconds |
|
|
RC510 γX-ray imaging |
GAGGcrystal |
10mSv/h |
500cps |
High sensitivity sensor, encoding hole imaging technology Quickly identify and locate radiation sources |
|
Neutronsγ |
R60N |
10×10×10(mm3)Koley PatentHType sensor |
10mSv/h(Neutron) |
0.5cps(Cf-252 ) |
A single sensor can simultaneously detect neutrons andγray γPSRR≥1000:1 High sensitivity under the same volume3Hesensor20times |
20×20×20(mm3)Koley PatentHType sensor |
2.7cps(Cf-252 ) |
||||
Wall mountedR2000 | |||||
|
γ
|
GM30A |
Geiger counter |
1mSv/h |
2cps |
Small end window cover leather tube X、γEnergy response:50keV-3MeV |
CS30A |
Φ30x30mm plastic scintillator |
1mSv/h |
350cps |
1Quick response in seconds |
|
CS75 |
Φ75x75mmplastic scintillator |
0.2mSv/h |
1500cps |
Environmental grade High sensitivity |
|
Neutronsγ |
N10 |
10×10×10(mm3)Koley PatentHType sensor |
10mSv/h(neutron) |
0.5cps(Cf-252 ) |
A single sensor can simultaneously detect neutrons andγray γPSRR≥1000:1 High sensitivity under the same volume3Hesensor20times |
N20 |
20×20×20(mm3)Koley PatentHType sensor |
2.7cps(Cf-252 )
|
|||
simpleDescribe
Koley Technology Co., LtdofR100typeX、 γIndividual dose (rate)call the policeThe upgraded version of the instrument adopts a high-performance microprocessor and a high-sensitivity energy compensation type internallyGMTube radiation detector has a fast response speed to radiation of different energies.itFully considering its use in harsh environments, it is resistant to high-strength impacts, high and low temperatures, and provides reliable and accurate measurement data,Lightweight, high-strength body, very sturdy.R100Capable of measuring dose equivalent rate while accumulating dose equivalents; There are sound, light, and vibration alarm functions, and users can customize the alarm threshold and dose equivalent reminder value according to their actual needs. Through the upper computer softwareR100It can also communicate with computers, making it convenient for users to download, analyze, and store dose data.
R100typeX、 γIndividual dose (rate)call the policeThe instrument can be widely used for radiation dose monitoring of nuclear power plants, environmental protection bureaus, chemical defense forces, entry-exit inspection and quarantine, and customs personnel; Radiation dose monitoring for employees in irradiation plants, thickness gauges, non-destructive testing, level gauges, nuclear scales, etc; Engaged in radiation dose testing for practitioners engaged in radiation therapy, nuclear technology applications, uranium and radium mines, etc.
Performance characteristics
High sensitivity, fast response
Simultaneously measuring dose equivalent rate andaccumulateDose equivalent, split screen display
Equipped with dose rate and cumulative dose over limit alarm function
Pre set alarm threshold and alarm prompt method
Two sections5namePowered by dry batteries, with battery undervoltage alarm function
Clock display function, data saved after shutdown, clock running as usual (battery not removed)
USBData interface, capable of communicating with computers, equipped with personal dose management software
Adopting microcontroller technology, it has multiple functions, small size, simple instrument operation, and easy use
Single instrument, can be set up10Group user ID, functions do not interfere with each other
Technical Parameter
detector |
GMCounting tube (with energy compensation) |
measuring range |
Dose equivalent rate:0.01μSv/h~10S/h Dose equivalent (cumulative dose):0.00μSv~10Sv |
Energy Response |
20keV~3MeV(≤±25%) |
sensitivity |
1μSv/h≥2cps(be relative toCs137) |
Display mode |
LCD display, dose equivalent rate(μSv/h)And dose equivalent(μSv) |
relative error |
dose equivalent rate≤±10%, dose equivalent≤±10% |
Protection alarm response time |
≤2Second (in dose equivalent rate)≥15μSv/h) |
power consumption |
<2.5mWendurance30Working days |
External dimensions |
116(H)×60(W)×22(D) |
net weight |
76g(No battery) |
operation temperature |
-10℃~50℃ |
Relative humidity range |
≤90%RH(40℃) |