Description:
SP-LDE series sulfuric acid flowmeter, digital meter for measuring dilute hydrochloric acidIts all Chinese electromagnetic converter core adopts a high-speed central processing unit. The calculation speed is very fast, the accuracy is high, and the measurement performance is reliable. It can measure the flow rate of fluid media with lower conductivity. The sensor adopts non-uniform magnetic field technology and a special magnetic circuit structure, which makes the magnetic field stable and reliable, and greatly reduces the volume, reduces repetition, and makes the flowmeter small and flow oriented.
Working principle
SP-LDE seriesSulfuric acid flowmeter, digital meter for measuring dilute hydrochloric acidBased on Faraday's law of electromagnetic induction. The measuring tube of the flowmeter is a non-magnetic alloy short tube lined with insulating material. Two electrodes are fixed on the measuring tube by passing through the tube wall along the diameter direction. The electrode tip is basically flush with the inner surface of the lining. When the excitation coil is excited by two pulse waves, a working magnetic field with a magnetic flux density of B will be generated in the direction perpendicular to the axis of the measuring tube. At this point, if a fluid with a certain conductivity flows through the measuring tube. Induce an electromotive force E by cutting the magnetic field lines. The electromotive force E is proportional to the magnetic flux density B. Measure the product of the inner diameter d of the tube and the average flow velocity v. The electromotive force E (flow signal) is detected by the electrode and sent to the converter through a cable. After amplifying and processing the flow signal, the converter can display the fluid flow rate and output signals such as pulses and analog currents for flow control and regulation.
How to choose protection level
According to the national standard GB4208-84 and the International Electrotechnical Commission standard IEC529-76 regarding the protection level of enclosures, the standard is:
IP65: Anti spray type, allowing the faucet to spray water on the sensor from any direction, with a spray pressure of 30KPa, a water output of 12.5L/s, and a distance of 3 meters.
IP68: Submersible type, capable of long-term operation in water.
The protection level should be selected according to the actual situation. The sensor should be installed below the ground. If it is frequently flooded, IP68 should be selected. When the sensor is installed on the ground, IP65 should be selected
How to choose additional features
The basic model comes with display, 4-20mA output, and 0-1kHz alarm functions. Other additional functions can be added according to the actual situation.
Split installation: If the sensor needs to be installed below the ground or for other reasons, a split installation method should be selected.
RS-485 communication: If communication between sensors and other devices is required, RS-485 communication function should be selected.

Sulfuric acid flowmeter, digital meter for measuring dilute hydrochloric acidPerformance parameters:
|
Nominal diameter DN |
10,15,20.25,32,40,50,65,80,100,125,150,200,250,300,350,400,500,600……. .1800 |
|
Nominal pressure Mpa |
0.6,1.0,1.6,2.5,4.0MPa |
|
Process connection |
Flange connection, flange standard: GB/T9119-2000 |
|
structural style |
Integrated (IP65), Split (IP65 and IP68) |
|
Lining material |
Polytetrafluoroethylene (≥ DN25), chloroprene rubber (≥ DN65), F46, Polyurethane, |
|
Electrode material |
Platinum, Platinum, Hastelloy, Titanium, 316L, Tungsten Carbide |
|
Measurement tube material |
304 stainless steel |
|
Shell and flange materials |
Carbon steel (standard), stainless steel (non-standard customized) |
|
Fluid temperature |
≤180℃ |
|
Explosion proof sign |
Not explosion-proof |
|
accuracy class |
Level 0.5 (within the range of 0.3m/s to 10m/s) |
|
repeatability |
0.15% |
|
Measurable flow velocity range |
0.05m/s~12m/s |
|
Effective measurement of flow velocity range |
0.3m/s to 10m/s (accuracy level 0.5) |
|
power supply |
18-36VDC or 85-265VAC, power: less than 8W |
|
output |
4-20mA, Frequency output (0-10KHZ), pulse equivalent |
|
Excitation method |
Three amplitude low-frequency rectangular wave excitation and high-frequency excitation |
|
exciting current |
160mA |
|
Require the minimum conductivity of the medium |
≥0.5μs/cm2 |
|
electrical interface |
M18×1.5 |
|
protection grade |
IP65 (one-piece, split type), IP68 (split type) |
|
Grounding method |
Grounding ring (user specified) or grounding electrode, pipeline grounding |
|
Display mode |
Display screen resolution FSTN mode 128 × 64 |
|
Power outage data storage time |
Power off memory EEPROM, the set parameters and flow accumulation data will not be permanently lost after power failure |
|
mean time between failures |
MTBF=30000h |

Sulfuric acid flowmeter, digital meter for measuring dilute hydrochloric acidSelection of lining:
|
Lining material |
Performance |
scope of application |
|
chloroprene rubber Neoprene |
Good wear resistance, excellent elasticity, high tensile strength, and resistance to corrosion from low concentration acid-base salt media, but not resistant to corrosion from oxidizing media. |
<80 ° C, general water, sewage, mud, slurry |
|
polyurethane Polyurethane |
Has excellent wear resistance, but slightly inferior acid and alkali resistance. |
<60 ° C, neutral and strongly worn mineral slurry, coal slurry, and mud. |
|
PTFE PTFE |
The most stable material in terms of chemical properties, capable of withstanding boiling hydrochloric acid, sulfuric acid, nitric acid, aqua regia, concentrated alkali, and various organic solvents. |
<180 ° C, strong corrosive media such as concentrated acid and alkali, sanitary media. |
|
F46 |
Chemical stability, electrical insulation, lubricity, non adhesiveness, and non flammability are similar to PTFE, but F46 material has better strength, aging resistance, temperature resistance, and low-temperature flexibility than PTFE. Good adhesion to metal, better wear resistance than PTFE, with good performance |
<180 ° C, hydrochloric acid, sulfuric acid, aqua regia, and strong oxidants, sanitary media |
| model | caliber | |||||
| SP-LDE | 15~2600 | |||||
| code | Electrode material | |||||
| K1 | 316L | |||||
| K2 | HB | |||||
| K3 | HC | |||||
| K4 | titanium | |||||
| K5 | tantalum | |||||
| K6 | platinum alloy | |||||
| K7 | Stainless steel coated with tungsten carbide | |||||
| code | Lining material | |||||
| C1 | Polytetrafluoroethylene (F4) | |||||
| C2 | Perfluoroethylene propylene (F46) | |||||
| C3 | Polyfluoroethylene (FS) | |||||
| C4 | Polyvinyl rubber | |||||
| C5 | polyurethane rubber | |||||
| code | function | |||||
| E1 | Level 0.3 | |||||
| E2 | Level 0.5 | |||||
| E3 | Level 1 | |||||
| F1 | 4-20Madc, Load ≤ 750 Ω | |||||
| F2 | 0-3kHz, 5V active, variable pulse width, output high-end effective frequency | |||||
| F3 | RS485 interface | |||||
| T1 | Normal temperature type | |||||
| T2 | High temperature type | |||||
| T3 | Ultra high temperature type | |||||
| P1 | 1.0MPa | |||||
| P2 | 1.6MPa | |||||
| P3 | 4.0MPa | |||||
| P4 | 16MPa | |||||
| D1 | 220VAC±10% | |||||
| D2 | 24VDC±10% | |||||
| J1 | Integrated structure | |||||
| J2 | Split type structure | |||||
| J3 | Explosion proof integrated structure | |||||