QD6000 multi-point monitoring gas detection and alarm controller is used to detect the content of flammable gases or liquid vapors in the air within the lower explosive limit. It can be equipped with multiple detection probes and centrally control multiple points. This system uses a microprocessor as the control unit and high-performance catalytic gas sensors as the detection sensors, with high sensitivity and fast response speed. When the concentration of flammable gases in the environment reaches or exceeds the preset alarm value, the controller immediately issues an audible and visual alarm and drives exhaust or other peripheral devices to prevent explosions and fire accidents, thereby ensuring life. This system can be widely used in factories, oil depots, liquefied gas stations, gas stations, gas stations, paint spraying rooms and other places that require fire and explosion prevention for safety detection and alarm.
Product Features:
Measurement range:% LEL,% VOL, PPM
Accuracy: ± 3% F.S;
Sensor model: 4-20mA or RS485
◆ Alarm point: two-level alarm, can be freely set by the user
◆ Preset value: (EX) Low report: 20% LEL High report: 50% LEL
◆ Indication method: LED digital display of concentration data, LED indication of alarm or fault status
Output mode: switch quantity MAX 3.0A
◆ Working method: on-site fixed installation, wall mounted
◆ Networking capacity: Divided into 3 channels, 4 channels, 5 channels, 6 channels, 7 channels, and 8 channels
◆ Natural diffusion, continuous operation
Working environment: Temperature -20-50 ℃, humidity<95% RH
Working voltage: AC220V ± 10% 50HZ
Power: Monitor Max 6W Sensor Max 1W
Execution standard: GB16808-2008
◆ Dimensions: Length * Width * Thickness (cm); 45 * 25 * 13 (including hanging board)
Requirements for the connection line between the system and external (gas) detectors:
Standard bus 2-wire connection method, with 2 single core wires with a diameter of ≥ 2.5mm and a length of ≤ 1000m
Standard 3-wire split connection method, with 3 single core wires with a diameter of ≥ 1.5mm and a length of ≤ 1000m
Standard bus 4-wire connection method, with 4 single core wires with a diameter of ≥ 1.5mm and a length of ≤ 1000m
|
Tested gas
|
measurement range
|
Optional range
|
resolution
|
response time
|
|
Flammable EX
|
0-100%LEL
|
0-100%VOL
|
1%LEL/1%vol
|
≤ 15 seconds
|
|
Carbon monoxide CO
|
0-1000PPm
|
0-500/2000/5000PPm
|
0.1/1PPm
|
≤ 15 seconds
|
|
TVOC
|
0-100PPM
|
0-100PPM
|
0.1PPm/1PPM
|
≤ 20 seconds
|
|
hydrogen
|
0-100%LEL
|
0-1000PPM
|
1%LEL/1PPM
|
≤ 20 seconds
|
|
natural gas
|
0-100%LEL
|
0-100%LEL
|
1%LEL
|
≤ 15 seconds
|
|
Oxygen O2
|
0-30%VOL
|
0-30%、0-100%VOL
|
0.1%vol
|
≤ 15 seconds
|
|
Ozone O3
|
0-10PPm
|
0-20、100PPm
|
0.01PPm/0.1PPM
|
≤ 20 seconds
|
|
Hydrogen sulfide H2S
|
0-100PPm
|
0-50、200、1000PPm
|
1/0.1PPm
|
≤ 15 seconds
|
|
methane
|
0-100%LEL
|
0-100%VOL
|
1%LEL/1%vol
|
≤ 15 seconds
|
|
Fluorine gas
|
0-10PM
|
0-1、10PPM
|
1/0.1PPm
|
≤ 20 seconds
|
|
hydrogen chloride
|
0-20PPm
|
0-20/50PPm/100PPM
|
0.01/0.1PPm
|
≤ 20 seconds
|
|
Nitrogen N2
|
0-30%VOL
|
0-30%VOL、100%VOL
|
0.1%LEL/1PPM
|
≤ 15 seconds
|
|
Hydrogen H2
|
0-100%LEL
|
0-1000PPm
|
1%LEL/0.1PPm
|
≤ 20 seconds
|
|
Chlorine gas CL2
|
0-20PPm
|
0-10、100PPm
|
0.1PPm
|
≤ 20 seconds
|
|
Ammonia NH3
|
0-100PPm
|
0-50、500、1000PPm
|
1/0.1PPm
|
≤ 20 seconds
|
|
nitrogen oxides
|
0-20PPm
|
0-50、1000PPm
|
0.1/1PPm
|
≤ 20 seconds
|
|
formaldehyde
|
0-20PPm
|
0-50、100PPm
|
1/0.1PPm
|
≤ 20 seconds
|
|
Sulfur dioxide SO2
|
0-20PPm
|
0-50、1000PPm
|
0.1/1PPm
|
≤ 20 seconds
|
|
Nitric oxide NO
|
0-250PPm
|
0-500、1000PPm
|
1PPm
|
≤ 20 seconds
|
|
Nitrogen dioxide NO2
|
0-20PPm
|
0-50、1000PPm
|
0.1/1PPm
|
≤ 20 seconds
|
|
phosphine
|
0-20PPm
|
0-20、100PPm
|
0.1PPm
|
≤ 20 seconds
|
|
acrylonitrile
|
0-100PPM
|
0-100PPm
|
0.1/1PPm
|
≤ 20 seconds
|
|
carbon dioxide
|
0-5000PPm
|
0-1%/5%/10% VOL (infrared)
|
1、0/01PPm
|
≤ 20 seconds
|
|
hydrogen fluoride
|
0-10PPm
|
0-1、10、50、100PPM
|
0.01/0.1PPm
|
≤ 20 seconds
|
|
Xylene, toluene
|
0-20PPm
|
0-5、10、50、100PPm
|
0.01/0.1PPm
|
≤ 20 seconds
|
|
Ozone O3
|
0-10PPm
|
0-20、100PPm
|
0.1/0.01PPm
|
≤ 20 seconds
|
|
Please contact the company for unlisted gases
|