1、 Product application
The HCS4033 series pressure transmitter digital instrument has the characteristics of good user interface and high accuracy. Parameter settings can be made through control keys, HART communication, PROFIBUS PA, or the Foundation's on-site main interface Transmitters that meet the requirements of 'intrinsic safety' and 'explosion-proof' can be installed in potentially explosive atmospheres (Zone 1) or (Zone 0). The ZDS4033 series pressure transmitter can be used in industrial fields with extreme chemical and mechanical loads. The electromagnetic compatibility within the range of 10KHz to 1GHz makes the HCS4033 series pressure transmitter suitable for high electromagnetic radiation applications. Different models of series transmitters can be used to measure: gauge pressure, absolute pressure, differential pressure, liquid level, and flow rate.
2、 Product parameters
Input signal: Range, maximum pressure, nominal measurement range
0.01~1bar g 6bar g 1bar g
0.04~4bar g 10bar g 4bar g
0.16~16bar g 32bar g 16bar g
Output signal: 4-20mADC output, digital PROFIBUS PA or FF Foundation bus signal, lower limit (continuously adjustable) 3.55mA, factory preset 3.84mA; upper limit (continuously adjustable) 23 mA, factory preset 20.5 mA or choose to set 22.0 mA.
Measurement accuracy: Linear characteristic curve
-r≤10 ≤(0.0029•r+0.071)%
-10 -30 Long term temperature drift ≤ (0.25 • r)%/5 years The impact of environmental temperature At -10~+60 ℃ ≤ (0.08 • r+0.1)% At -40~-10 ℃ ≤ (0.1 • r+0.15)%/10 3、 Product Features 1. Main features of the series of intelligent differential pressure/pressure transmitters 2. Measurement medium: gas, vapor, liquid 3. Accuracy: 0.075% (including dead zone, hysteresis, repeatability, etc.) 4. Wide range ratio: 100:1 5. Wide measurement range (before relocation): 6. Differential pressure range 0-100Pa~3MPa 7. Pressure range 0-1kPa~40MPa 8. Stability and reliability 9. Long term drift of 0.25%/5 years, measured<0.1%/5 years 10. Safety level SIL2, MTBF, 1997 11.5 years maintenance free, saving maintenance and repair costs 12. Temperature and static pressure have little impact and can be ignored 13. Excellent unidirectional overload characteristics 14. High static pressure: 16MPa, 42MPa 15. Wide temperature range: ambient temperature -40 ° C~85 ° C, measured medium temperature -90 ° C~350 ° C 16. Output compatible with multiple fieldbus: 4~20mA/HART, PROFIBUS-PA, FF 17. The universal debugging software SIMATIC PDM can achieve remote online management of all transmitters 18. Lightning protection, electromagnetic interference resistance, vibration resistance, moisture resistance, overvoltage resistance, and resistance to environmental temperature changes 19. Rich debugging methods: on-site buttons, handheld devices SIMATIC PDM、 control system 20. Self diagnosis, fault alarm, circuit testing, self configuration 21. Universal installation bracket, stainless steel nameplate 22. Fast dynamic response 23. Complete explosion-proof certification Exia ll CT6 Exd ll CT6 24. FDA, EHEDG, GMP certified sanitary transmitters 25. Rich selection of matching valve groups and conversion joints 26. Rich filling fluids: silicone oil, high-temperature silicone oil, inert fluid, vegetable oil, glycerin/water 27. Unique and powerful on-site buttons 28. High overlapping adjacent ranges ensure continuous accuracy 29. Intelligent display technology is easier to operate and understand
4、 Technical data