Main features of power meter PW3336-01/-02/-03: Accurate measurement of maximum AC/DC1000V/65A through direct input. The instrument supports 2-hour in
Product details

Main features of power meter PW3336-01/-02/-03:

Accurate measurement of maximum AC/DC 1000V/65A instrument using direct input method

Supports 2-hour input, DC、 Measurable single-phase 2-wire~three-phase 3-wire
Used for the development and production of motors, frequency converters, power regulators, power supplies, etc
High basic accuracy: ± 0.15%
Broadband: DC, 0.1Hz~100kHz
The maximum measurable high current under direct input mode is 65A
Standard harmonic measurement: compliant with IEC61000-4-7
In the no-load test of transformers/motors, high-precision measurement can be achieved even with low power factor
Supports maximum AC 5000A input with external current sensor input port
Up to 8 instruments can be controlled simultaneously

Model difference of power meter PW3336-01/-02/-03:

PW3336(2ch)
PW3336-01(2ch, 带 GP-IB)
PW3336-02 (2ch, with D/A output)
PW3336-03 (2ch, with GP-IB and D/A outputs)

Measurement line Single phase 2-wire, single-phase 3-wire, three-phase 3-wire (voltage/current range can be set for each connection)
measurement items Voltage, current, active power, apparent power, reactive power, power factor, phase angle, frequency, efficiency, current accumulation, active power accumulation, accumulation time, voltage waveform peak, current waveform peak, voltage crest factor, current crest factor, time average current, time average effective power, voltage ripple rate, current ripple rate
Harmonic related projects Synchronous frequency range: 10Hz~640Hz, analysis frequency: up to 50 times
Harmonic voltage effective value, harmonic current effective value, harmonic active power, total harmonic voltage distortion rate, total harmonic current distortion rate, fundamental voltage, fundamental current, fundamental active power, fundamental apparent power, fundamental reactive power, fundamental power factor (displacement power factor), fundamental voltage current phase difference, channel voltage fundamental phase difference, channel current fundamental phase difference, harmonic voltage content, harmonic current content, harmonic active power content (only available for data obtained through dedicated software: harmonic voltage phase angle, harmonic current phase angle, harmonic voltage current phase difference)
measurement range [Voltage] AC/DC 15V~1000V, 7-speed range
[Current] AC/DC 200mA~50A, 8-speed range
[Power] 3.0000W~100.00kW (depending on the combination of voltage and current ranges)
Accumulated measurement
(Accumulated: less than 10000 hours)
[Current] 6-digit display (0.00000 mAh~, polarity classification and comprehensive value)
[Active power] 6-digit display (0.00000 mWh~, polarity classification and comprehensive value)
Input resistance (50/60 Hz) Voltage: 2 M Ω, current: below 1 m Ω (direct input)
Basic accuracy
(Active power)
±0.1% rdg. ±0.1% f.s. (DC)
± 0.1% rdg. ± 0.05% f.s (45 Hz~66 Hz, input<50% f.s)
± 0.15% rdg. (45 Hz~66 Hz, 50% f.s ≤ input)
Display update rate About 5 times/s to 20 seconds (varies according to the average frequency setting)
frequency characteristic DC,0.1Hz~100kHz
D/A output
Limited to -02/-03
16ch (select output item below), level output DC ± 2 V, waveform output 1 V f.s, level output/waveform output (voltage/current/active power), level output (apparent power/reactive power/power factor, etc.), high-speed active power level output
function [Rectification Mode Switching] AC+DC, AC+DC Umn, AC, DC, FND
Automatic range, average value, VT · CT setting, synchronous control, MAX/MIN, etc
interface Standard RS-232C/LAN, supports GP-IB (limited to -01, -03)
power supply AC 100 V~240 V, 50/60 Hz, 40 VA
Volume and weight 305W × 132H × 256D mm, 5.2 kg
attachment User manual x 1, measurement guide x 1, power cord x 1

Power meter PW3336-01/-02/-03 Main purpose:

Measurement of power consumption of household appliances (AC appliances, white goods, air conditioning equipment)
Measurement of power consumption of industrial machinery (air conditioning equipment, work machines, communication equipment)
Characteristic evaluation of motors, transformers, power supplies, frequency converters, power regulators, etc
Power meter PW3336-01/-02/-03 optional accessories:

Can be directly connected to the input port of the current sensor (for single-phase x 1, for three-phase x 2)
Clamp sensor 9660
钳式传感器 9660 100 A AC
Jaw diameter: 15mm
Line length: 3m
details
Clamp sensor 9661
钳式传感器 9661 500 A AC
Jaw diameter: 46mm
Line length: 3m
details
Flexible clamp sensor CT9667
钳式传感器 9661 AC5000/500A,φ 254 mm, The wire length between the sensor and the control box is 2m, and the output wire length is 1m
details
Clamp sensor 9669
钳式传感器 9661

1000A AC
Jaw diameter: 55mm
Line length: 3m

details
Current input (TYPE2)
Need sensor unit 9555-10 and connecting wire L9217 (for single-phase x 1, for three-phase x 2 or x 3)
AC/DC current sensor CT6865
rated current 500 A AC/DC (continuous 650 A rms/920 A peak) CAT III 1000V, Rated current AC/DC1000A, DC~20kHz response, wire diameter 36mm, wire length 3m
details
AC/DC current sensor 9709
AC/DC CURRENT SENSOR 9709 CAT III 1000V, Rated current AC/DC 500A, DC~100kHz response, wire diameter 36mm, wire length 3m
details
AC/DC current sensor CT6863
rated current 500 A AC/DC (continuous 650 A rms/920 A peak) CAT III 1000 V, Rated current AC/DC 200A, DC~500kHz response, wire diameter 24mm, wire length 3m
details
AC/DC current sensor CT6862
rated current 500 A AC/DC (continuous 650 A rms/920 A peak) CAT III 1000 V, Rated current AC/DC 50A, DC~1MHz response, wire diameter 24mm, wire length 3m
details
Universal clamp CT 9279
通用钳式CT 9279 Observe waveform distortion from DC to AC. DC 20kHz response, input 500A/output 2V AC, non CE marked product
details
Universal clamp CT 9278
通用钳式CT 9278 Observe waveform distortion from DC to AC. DC 100kHz response, input 200A/output 2V AC
details
Universal clamp CT 9277
通用钳式CT 9277 Observe waveform distortion from DC to AC. DC 100kHz response, input 20A/output 2V AC
details
Clamp sensor 9272-10
钳式传感器 9272-10 It can be used to observe the deformation of AC current waveform. Input: Up to 20/200A, 2V AC output
details
Power supply unit 9555-10
传感器单元 9555-10 The power unit is suitable for connecting 9272 to 9279 clamp sensors. In addition to connecting 8951, signal output requires the use of 9217.
details
Connection line L9217
连接线 9217 Both ends of the wire have insulated BNC connectors and are connected to the insulated BNC connectors on the input module. Length 1.7m
PC communication
LAN line 9642
LAN CABLE 9642 Non crossover Ethernet cable, providing a conversion line from direct connection to crossover, 5m long
RS-232C cable 9637
line
RS-232C 电缆 9637 9pin-9pin, 1.8m long
RS-232C cable 9638
RS-232C 电缆 9638 9pin-25pin, Cross type cable/1.8m long
GP-IB connection cable 9151-02
line
9151-02 2 meters long
other
9165 is used for synchronous control
Connection line 9165
连接线 9165 Both ends of the wire have metal BNC connectors and are connected to the metal BNC connectors. 1.5m long, non CE marked product
Socket connection wire 9266-01
Power measurement fixture

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!