VIP member
Portable turbidity meter
The German WTW portable turbidity measuring instrument Turb430 can achieve laboratory measurement accuracy, using the principle of 90 degree scattered
Product details
German WTW portable turbidity measuring instrument Turb430
feature
· Scattering light test
· Tested in accordance with pharmacopoeia5.0specification
· multi-functionalLabStation
· Compliant with strict requirementsGLP/AQArequirement
· Completely waterproof, IP67
Portable turbidity testerTurb430Tungsten lamp or infrared lamp
Turb 430The portable turbidity detector can meet the testing accuracy requirements of the laboratory. It adopts90Measurement of turbidity by scattered light method.Turb 430 IRThe portable turbidity detector adopts infrared technologyLED(860nm))Based onISO 7027/DIN/EN 27027(EN ISO7027)Standard,Turb 430TPortable turbidity detector using tungsten lamp(according toUS EPA)Conduct turbidity testing. Its testing range is0to1100NTUThe automatic range switching function of the instrument,1to3The point correction function makes the operation more convenient.There is no problem testing low turbidity drinking water!
Turb 430The portable turbidity detector can meet the testing accuracy requirements of the laboratory. It adopts90Measurement of turbidity by scattered light method.Turb 430 IRThe portable turbidity detector adopts infrared technologyLED(860nm))Based onISO 7027/DIN/EN 27027(EN ISO7027)Standard,Turb 430TPortable turbidity detector using tungsten lamp(according toUS EPA)Conduct turbidity testing. Its testing range is0to1100NTUThe automatic range switching function of the instrument,1to3The point correction function makes the operation more convenient.There is no problem testing low turbidity drinking water!
Portable turbidity detectorTurb430Adopting menu operation, the interface is friendly and simple, and any user can easily get started. Correction adopted3Point calibration, standard equipment0.02, 10, 1000NTUThree bottles of standard solution, storable1000Group testing data. Users can set calibration intervals to evaluate the quality of test results. Users can choose a portable outdoor case and rechargeable battery, and pack the host and necessary accessories in a lightweight portable case to immediately set up a small laboratory in the field.
Technical Specifications
|
Test Principle
|
90°scattered light method
|
|
Light source
|
Turb 430 IR: IR-LED, 860 nm;
Turb 430T:tungsten lamp
|
|
Range
|
0…1100NTUAutomatic range switching
|
|
dividedistinguishrate
|
0.01NTU(0.00…9.99NTU);
0.1NTU(10.0…99.9);
1NTU(100…1100)
|
|
accurateindeeddegree
|
0.01 NTUor±2%test value
|
|
againnowsex
|
<±0.5%Test value or0.01NTU
|
|
correction
|
automatic1…3Point Correction
|
|
reaction time
|
3Second(IR),7Second (tungsten lamp)
|
|
Test tubes used
|
28X60mm,sample volume20ml
|
|
interface
|
RS232, with adapterUSB
|
|
Protection level
|
IP67
|
|
special function
|
1000Group data storage, calibration protocol storage, real-time clock
|
|
size
|
Instrument:236 x 86 x 117
|
|
weight
|
0.6 kg
|
|
Operating temperature
|
0…50°C
|
|
power supply
|
4aAAAlkaline battery, two thousandNext (tungsten lamp) or3000Next time(IR)
|
|
certification
|
CE,TUV/GS
|
Ordering Information
|
Portable turbidity meter
|
Instructions
|
Order Number
|
priceRMB
|
|
Turb 430IR/SET
|
Portable turbidity meter,90Infrared light, supplied in sets, including calibration solution(0.02-10.0-1000NTU)and4An empty test tube(28mm)Cleaning brushes, etc
|
600321
|
26,080.00
|
|
Turb 430T/SET
|
Portable turbidity meter,90Tungsten lamp, complete supply, including calibration solution(0.02-10.0-1000NTU)and4An empty test tube(28mm)Cleaning brushes, etc
|
600326
|
27,200.00
|
|
Turb 355IR
|
Portable turbidity meter,90Infrared light, supplied in sets, including calibration solution(0.02-10.0-1000NTU)and2An empty test tube, cleaning brush, etc
|
600311
|
20,960.00
|
|
Turb 355T
|
Portable turbidity meter,90Tungsten lamp, complete supply, including calibration solution(0.02-10.0-1000NTU)and2An empty test tube, cleaning brush, etc
|
600312
|
21,920.00
|
|
Laboratory turbidity meter
|
|
|
|
|
Turb 550
|
White light laboratory turbidity meter, containing calibration solution(0.02-10.0-1000NTU)and2An empty test tube, optional: continuous measurement slotD-Turb(600600)
|
600100
|
27,232.00
|
|
Turb 550IR
|
Red light laboratory turbidity meter, containing calibration solution(0.02-10.0-1000NTU)and2An empty test tube, optional: continuous measurement slotD-Turb(600600)
|
600110
|
33,616.00
|
|
Turb 555
|
High performance white light laboratory turbidity meter, including calibration solution(0.02-10.0-100-1750NTU)and3An empty test tube, optional: with a pressure resistance of1barContinuous measurement slotD-Turb(600605)
|
600200
|
44,768.00
|
|
Turb 555IR
|
High performance red light laboratory turbidity meter, including calibration solution(0.02-10.0-100-1750NTU)and3An empty test tube, optional: with a pressure resistance of1barContinuous measurement slotD-Turb(600605)
|
600210
|
50,848.00
|