Portable transformer oil and gas chromatograph
Under normal circumstances, the insulation oil and organic insulation materials in the transformer oil and electrical equipment of the portable transf
Product details
Portable transformer oil and gas chromatograph
便携式变压器油气相色谱仪

Under normal circumstances, the insulation oil and organic insulation materials in transformer oil electrical equipment will gradually age and produce small amounts of various molecular hydrocarbons, carbon monoxide gas, carbon dioxide and other gases under the action of heat and electricity. Most of these gases will melt into the oil.
The composition and content of the faulty gas are closely related to the severity of the fault. Therefore, using this portable transformer oil gas chromatography to analyze gases dissolved in oil can detect potential faults inside the equipment as early as possible and grasp the occurrence of faults at any time, so as to promptly handle and eliminate faults and ensure the normal operation of the equipment.
This instrument can analyze and monitor seven types of fault gases in transformer oil: (H2/CO/CO2/CH4/C2H6/C2H4/C2H2)
Key Features:
1. The instrument is equipped with two detectors, thermal conductivity and hydrogen flame, as well as a conversion furnace. With one injection, it can achieve analysis of seven gases.
2. The thermal conductivity adopts high resistance rhenium tungsten wire and built-in amplification circuit, greatly improving the sensitivity of hydrogen detection.
3. It has automatic ignition and gas cut-off protection functions.
4. High control accuracy, stable airflow, ensuring the repeatability of analysis results.
5. Modular design, compact structure, and easy maintenance.
Technical indicators:
Temperature control range:
Column box: greenhouse+8 ℃ -400 ℃
Detector: Greenhouse+8 ℃ -400 ℃
Converter: greenhouse+8 ℃ -400 ℃
Temperature control: ± 0.1 ℃ (at 200 ℃)
Hydrogen flame sensitivity: Dt ≤ 5 * 10-12g/s
Noise: ≤ 5 * 10-15A
Drift: ≤ 1 * 10-12A/30min
Superconducting sensitivity: S ≥ 600mm. ml/mg (benzene/toluene)
Noise: ≤ 20UV
Drift: ≤ 30UV/30min
Instrument usage requirements:
1. Current and voltage: 220 ± 22v/50/60HZ
2. Total power of the instrument: 500W
3. Environmental temperature:+5 ℃ -75 ℃
4. Relative temperature:<85 ℃