PP material anti-corrosion magnetic flap level gauge
The PP material anti-corrosion magnetic flap level gauge produced by Meiante Company is suitable for measuring liquid levels in corrosive media and hi
Product details

The PP material anti-corrosion magnetic flap level gauge produced by Meiante Company is suitable for measuring liquid levels in corrosive media and high operating temperatures. It has a reliable structure and a long service life. It is the preferred choice for measuring the liquid level of highly corrosive media such as hydrofluoric acid. Tailored for customers with low temperature and pressure requirements, our PP material level gauge can be used.

PP material side mounted (top mounted) anti-corrosion magnetic flap level gauge. Corrosion resistant magnetic flap level gauge is suitable for measuring the liquid level of underground storage tanks, tanks or pools with corrosive media. It is divided into the following forms for customers to choose from according to different media, temperature, pressure and other conditions. Users can use remote transmitters according to engineering needs, which can achieve local digital display and output standard remote transmission electrical signals of 4-20mA. It can be matched with various systems and can also be used with magnetostrictive level transmitters to meet the needs of recording instruments or industrial process control. It can also be used in conjunction with magnetic control switches or proximity switches to monitor liquid level alarms or control inlet and outlet equipment.

The magnetic float level gauge (also known as the magnetic flap level gauge) is developed based on the principle of buoyancy and magnetic coupling. When the liquid level in the tested container rises or falls, the magnetic float in the liquid level gauge body tube also rises or falls accordingly. The permanent magnetic steel inside the float is transmitted to the magnetic flip column indicator through magnetic coupling, driving the red and white flip columns to flip 180 °. When the liquid level rises, the flip column changes from white to red, and when the liquid level drops, it changes from red to white. The red white boundary of the indicator is the actual height of the liquid level inside the container, thus achieving clear indication of the liquid level.

Basic technical parameters of PP material side mounted (top mounted) anti-corrosion magnetic flap level gauge
Measurement range: 300-4000mm (can be specially customized when exceeding 5000mm)
Display accuracy: ± 10mm;
working pressure: PP: Atmospheric pressure
Medium temperature: PP: -20~70 ℃;
Medium density: ≥ 0.5g/cm3;
Medium viscosity: ≤ 0.4Pa·S;
Process connection: DN2025/50/80/150 PN1.0 (executing standard HG20592~20635-97), if other standards are required, they can be manufactured according to customer requirements.
Liquid receiving material:/ PP and so on
(Select according to the chemical properties of the medium and the temperature and pressure of use)
Float material: 316L PVC/UPVC/CPVC/PP、PTFE、 Titanium, etc.
Characteristics of PP material side mounted (top mounted) anti-corrosion magnetic flap level gauge

Suitable for measuring the liquid level and interface of liquid media in containers. In addition to on-site instructions, it can also be equipped with remote transmitters, alarm switches, and complete detection functions.
● The indication is novel, the reading is intuitive, eye-catching, and the direction of the observation indicator can be customized according to user needs
Change the angle.
The measurement range is large and not limited by the height of the storage tank.
The indicating mechanism is completely isolated from the tested medium, with good sealing, high reliability, and safe use.
● Simple structure, easy installation, easy maintenance, corrosion resistance, no need for power supply, explosion-proof.
Main technical indicators of basic magnetic flap level gauge
Measurement range: 500~18000mm
Accuracy: ± 5mm ± 10mm (high temperature type)
Work pressure: ≤ 2.5MPa (ordinary type)
≤ 10.0MPa (high pressure type)
≤ 32.0MPa (ultra-high pressure type)
≤ 2.5MPa (anti-corrosion type)
● Medium density: 0.45~2g/cm3
● Medium density difference: ≥ 0.15g/cm3 (measurement boundary)
● Medium temperature:- 80℃~+450℃
● Medium viscosity: ≤ 0.4Pa. s, for media with high viscosity or media that are prone to crystallization at low temperatures, a heating jacket type liquid level gauge can be selected according to user requirements.
Environmental vibration: frequency ≤ 25HZ, amplitude ≤ 0.5mm
Interface flange: Adopting the HG20592~20635-97 flange standard newly issued by the Ministry of Chemical Industry in 1997.
If users need to adopt other standards (such as GB, ANSI, DIN, etc.), they can design according to their needs.