VIP member
PMM8053B Electromagnetic Radiation Analyzer
PMM8053B Electromagnetic Radiation Analyzer
Product details

PMM8053BElectromagnetic radiation analyzer
*Currently, the only comprehensive electromagnetic field measurement system in the world that combines high and low frequencies
*5Hz-40GHz ultra wideband optional probe with full frequency coverage
*5Hz-100KHz spectrum analysis function, displaying XYZ values
*0.05v/m-1000v/m large dynamic electric field measurement range optional probe
*Three averaging modes: arithmetic mean, RMS mean, and spatial mean
*RS-232 interface fiber optic data transmission and 10-40 meter remote control
*Expandable connection of 16 probes for point monitoring (optional)
*An automatic monitoring system can be formed by connecting software to a computer (optional)
*High precision measurement with internal self calibration
*Dustproof, shockproof, easy to use
*After sales service and instrument usage training
Application scope
|
Power frequency(5Hz-100KHz)
|
RF (Radio Frequency)(100KHz-40GHz)
|
High voltage transmission and transformation systems, distribution rooms, induction furnaces, subways, trams and other workplaces
|
Various types of long wave, medium wave, short wave, and microwave radiation, including:
Workplaces with electromagnetic radiation, such as mobile phone stations, medical equipment, radar, satellite communication, TV antennas, pager stations, heat sealers, drying equipment, televisions, computers, etc
|
|
Instrument characteristics
|
*5Hz-100KHz spectrum analysis function* 0.05v/m-1000v/mLarge dynamic electric field measurement range with optional probe
|
|
*Electromagnetic field integrated enhanced probe* 8100A data storage table * Free software updates
|
||
*Proactively identify the frequency of pollution sources * Three types of averaging modes are available: arithmetic mean, RMS mean, and spatial mean
|
||
Random accessories
|
hostPMM8053B field strength measurement main unit, rechargeable battery, charger, data download software,RS232 interface, dedicated software package
|
|
Extended functionality
|
Scalable connection16 probes for point monitoring (optional), expandable to connect to GPS system
|
|
Options
|
10m20m, 40m, and 80m fiber optic cables, tripod, optical data converter, calibrator, telescopic pole, remote control software
|
◆apply
*Power frequency and radio frequency environment monitoring
*Environmental Impact Assessment
*Environmental background investigation
*Various targeted entrusted monitoring work
*Measurement of electromagnetic radiation protection in workplace
*Quality inspection of electromagnetic product manufacturing enterprises such as microwave ovens and induction cookers
*Defense electronic countermeasures electromagnetic security measurement
*Electromagnetic Environment Safety Testing of Aerospace Equipment
*Electromagnetic environment measurement of airport navigation radar
*Research on Electromagnetic Radiation in University Research Institutes
◆Standard probe configuration
PMM8053BThere are various non directional probes available, with a frequency range of 5Hz-40GHz and ultra wideband full frequency coverage, meeting the constantly developing Chinese national standards.
PMM8053BProvide electromagnetic environment background measurement probes with a measurement accuracy of up to 0.05v/m
PMM8053BProvide station measurement probes that can eliminate the influence of broadcast and television signals during measurement
model
|
simple parameters
|
Measurement function characteristics
|
low frequencyelectricity-Magnetic fieldmeasureProbe selection (power frequency measurement)
|
||
EHP-50C
|
electricity-Magnetic field: 5Hz-100KHz, isotropic
Range:0.01v/m-100Kv/m,1nT-10mT
Spectrum analysis function,7 options with fixed width
|
Low frequency electricity-The magnetic field dedicated measurement probe has powerful spectral analysis capabilities and is currently the world's most advanced power frequency measurement and analysis probe. It can solve the harmonic problems in power frequency measurement and identify and measure low-frequency broadband radiation signals. Independent 24-hour continuous monitoring function.
|
Selection of RF measurement electric field probe
|
||
EP-330
|
Frequency:100K-3GHz
Range:0.3-300v/m, isotropic
|
Measure frequency coverage of signals such as radio, television, radio, mobile phone stations, microwave ovens, induction cookers, etc., with measurement accuracy0.3v/m is suitable for better environmental monitoring and product quality testing requirements.
|
EP-300
|
Frequency:100K-3GHz
Range:0.1-300v/m, isotropic
|
Measure frequency coverage of signals such as radio, television, radio, mobile phone stations, microwave ovens, induction cookers, etc., with measurement accuracy0.1v/m, suitable for environmental background investigation, environmental monitoring, and product quality testing requirements.
|
EP-105
|
Frequency:100K-1GHz
Range:0.05-50v/m, isotropic
|
High precision probe, measuring frequency coverage of long wave navigation radar, radio, television, radio900M mobile phone station and other signals, with a measurement accuracy of 0.05v/m, mainly for environmental background investigation.
|
EP-301
|
Frequency:100K-3GHz
Range:1-1000v/m, isotropic
|
Measure frequency coverage of signals such as radio, television, radio, mobile phone stations, microwave ovens, induction cookers, etc., with measurement accuracy1v/m, suitable for general environmental monitoring and product quality testing requirements.
|
EP-183
|
Frequency:1M-18GHz
Range:0.8-800v/m, isotropic
|
The measurement frequency covers signals from radio, television, radio, mobile phone stations, radar, satellites, etc., mainly targeting common meteorological station radars, high-frequency microwave communication stations, navigation radars, satellites, and other millimeter wave signals.
|
EP-408
|
Frequency:1M-40GHz
Range:0.8-800v/m, isotropic
|
The measurement frequency covers signals from radio, television, radio, mobile phone stations, radar, satellites, etc., mainly targeting millimeter wave signals from common meteorological station radars, high-frequency microwave communication stations, navigation radars, satellites, and special-purpose radars.
|
EP-33M
|
Frequency:700M-3GHz
Range:0.3-300v/m, isotropic
|
Specially designed for measuring various mobile communication stations. Not affected by signals such as radio and television.
|
EP-44M
|
Frequency:100K-800MHz
Range:0.25-300v/m, isotropic
|
Specially designed for various radio, television, radio and other signals, unaffected by signals from various mobile communication stations.
|
Selection of RF measurement magnetic field probe
|
||
HP-102
|
Frequency:30M-1GHz
Range:0.01-20A/m, isotropic
|
Measure the frequency coverage of medium wave and short wave signals in broadcasting, television, radio, and other fields. Mainly used for near-field measurement.
|
HP-032
|
Frequency:100K-30MHz
Range:0.01-20A/m, isotropic
|
Measure the frequency coverage of broadcast long and medium wave signals.
|
◆PMM8053Bcharacteristic
* PMM8053BProviding users with a more user-friendly interface, users can classify and manage measurement data based on their measurement situation, and provide file names related to measurement, making it easy for users to manage all measurement results.
*The powerful extended data storage can reach 32700 data points, enabling users to manage measurement files for a longer period of time.
*Strict measurements will follow the "Electromagnetic Radiation Protection Regulations GB 8702-88" and related standards, requiring the standard measurement result of each measurement point to be the root mean square average (RMS average) of 6 consecutive minutes. In the case of simplified measurements, each measurement point should be measured no less than 5 times, and the maximum value of the measurement time during each measurement process of no less than 15 seconds should be selected to calculate the root mean square average (RMS average) of the 5 measurement results.
*PMM8053BWe provide users with a comprehensive solution, which can directly obtain the above measurement results through instruments. Users can set:
-Measurement of maximum values within a time interval of 1-999 seconds
-Root Mean Square (RMS) and Arithmetic Mean (AVG) are optional
-Automatic measurement completed
* PMM8053BOn the basis of measuring the electric field, it is possible to simultaneously complete the total magnetic field, horizontal magnetic field, and vertical magnetic field measurements required by the Technical Specification for Environmental Impact Assessment of Electromagnetic Radiation in 500kV Ultra High Voltage Transmission and Transformation Projects HJ/T 24-1998. At the same time, it also provides users with《Measurement of power frequency electric fieldHarmonic analysis in GB/T 12720-91.
* PMM8053BProvide users with powerful and practical measurement functions, capable of measuring 16 points simultaneously, making their measurement work more perfect. In addition, the 8053B instrument provides users with frequency selection function, allowing them to make further adjustments to the measurement
* Security guarantee for strong field measurement
The instrument provides accessories such as a 4-meter telescopic rod to ensure the safety of measurement personnel during strong field measurements
* Frequency selection measurement data correction function
In the case of a single radiation source, using the frequency selection function allows users to obtain more accurate measurement results
* Time domain measurement display
Through the time-domain display function, users can real-time understand the changes in radiation intensity during the measurement process
* 16A dot matrix measurement system with a probe
The instrument can form up to 16 probe array measurement systems with the same or different frequency bands, for detailed and meticulous long-term monitoring of large facilities and radiation sources.
◆EHP-50CProbe characteristics
The EHP-50C probe can measure electric and magnetic fields in the same probe, perfectly solving the problem of non coincidence between electric field measurement points and magnetic field measurement points in power frequency electromagnetic field measurement for a long time
The powerful spectrum analysis function of the EHP-50C probe allows users to easily confirm the frequency of the radiation source and solve problems such as harmonics
The EHP-50C probe can record spectrograms and output them to a computer, allowing users to easily and effortlessly make perfect measurement reports
EHP-50C probe can perform independent 24-hour continuous monitoring
7 different bandwidths for users to choose from for detailed data analysis
◆EHP-50CFunctional Features
EHP-50B is an analytical probe used for isotropic measurement of low-frequency electromagnetic fields, providing an excellent solution for low-frequency electromagnetic field measurement. The measurement range ranges fromV/m orNT to KV/m or mT, frequency range from 5 Hz to 100 kHz, including X,, Y. Z-axis. Probe withE2PROM calibration data.
Users can use identificationThe Marker function accurately measures frequency and field strength.
EHP-50A through internalThe CPU controls and manages all functions, including data processing, battery level management, and data communication management.
Spectrum analysis function for 5Hz-100KHz
*Electric magnetic field measurement
*7 broadband modes to choose from
*Flexible RMS data sampling rate setting
*Data logger function
*Time domain display
*Multiple average time settings
*Can be connected to a PC to display spectrograms
*Filter measurement at each frequency point
*Good data processing capabilities
|
electricity a place where people gather
|
magnetism a place where people gather
|
Frequency range
|
5 Hz – 100 kHz
|
|
measure Cheng
|
0.01 V/m – 100 kV/m
|
1 nT – 10 mT
|
cross year
|
200 kV/m
|
20 mT
|
dynamic range
|
> 140 dB
|
|
display resolution
|
0.01 V/m
|
1 nT
|
quickMinlinear measure
|
0.1 V/m
|
1 nT
|
Optional bandwidth
|
100 Hz, 200 Hz, 500 Hz, 1 kHz, 2 kHz, 10 kHz, 100 kHz
|
|
school accurate
|
Internal E2PROM
|
|
Temperature response
|
0.05 dB/°C
|
◆Electromagnetic radiation analyzer expansion function optional accessories
8053-CALcalibrator
pass through8053Main instrument charging, used for detection8053instrumentX、Y、ZAxis input function.
Standard reading:57.7v/m
Accuracy:+/- 2%
|
|
To avoid the influence of personnel during monitoring, PMM provides a good solution by connecting 10-80 meters of optical fiber between the 8053B main instrument and probe through OR-02 optical data repeater
|
OR-02Optical data repeater
|
8053-GPSAutomatic Global Positioning System
The 8053-GPS automatic global positioning system can be directly connected to the 8053 main instrument through optical fiber, or connected to the SB-04 data converter to display the coordinates of the positioning point. Use 8053-SW02 to store coordinates and field strength values
|
|
8053-SW02Data Acquisition Software
*Multiple data analyses can be conducted while measuring and storing data
*The chart displays the stored data in the recorder.
*Identify markers for point by point data analysis
*Comparison between measured values and user set limits
*Real time data chart display
|
SB-10Data exchange controller
*PMM SB-04 can support PMM8053 main instrument and various probes with OR-02 optical data repeater
*Up to 50 points can be monitored simultaneously, allowing various frequencies to be covered by probes and achieving full frequency monitoring
*The user's computer system controls the entire system through SW-02 software, enabling remote operation by the user
*Multiple lengths of optical fibers to choose from
◆PMM 8053BTechnical parameters of electromagnetic radiation analyzer
Frequency range
|
|
Frequency range
|
5 Hz - 40 GHz
|
dynamic range
|
>120 dB
|
one position
|
V/m, kV/m, mW/cm², W/m², A/m,mT, mT;
|
LCDDisplay data
|
|
Measurements
|
X. Absolute values, percentages, and total values in the Y and Z directions
|
time between
|
Built in clock time display
|
try to find out head
|
Display probe model and calibration time
|
Bar chart
|
Simulated intensity display (linear, logarithmic) corresponding to real-time measurement values
|
alarm threshold
|
|
Measurement function
|
|
sample time
|
150 ms with 80 Hz filter, 250 ms with 40 Hz filter, 450 ms with 20 Hz filter 900 ms with10 Hz filter
|
store store up
|
Single file storage of 32700 measurement data (8100 multi file storage of measurement data)
|
report guard against
|
Users can set thresholds. Sound and screen flashing signal alarm
|
work ability
|
*Small value, * large value, and average value (RMS average and Avg average are optional for users)
|
Average Mode
|
Arithmetic mean, root mean square (RMS) mean, manual and spatial mean
|
average time
|
32 sampling points are averaged, with options of 30 seconds, 1 minute, 2 minutes, 3 minutes, 6 minutes, 10 minutes, 15 minutes, and 30 minutes
|
data acquisition
|
Sampling mode (1.10-900 seconds/sampling), data variable values, threshold exceeded, 1 second, 10 seconds, 6 minutes -1 minute, 6 minutes -6 minutes
|
(Recorder)
|
6-minute average, manual, spectrum analysis (when using EHP-50A probe)
|
Time domain display
|
*Fast mode, 1 minute, 2 minutes, 10 minutes, 30 minutes, 60 minutes settings
|
General Instructions
|
|
apparent show
|
72x72mm LCD display screen with 128x128 pixels, RS232 interface (using cable or fiber optic)
|
built-in battery
|
Rechargeable NiMH battery (5 x 1.2 V)
|
Usage time
|
Normal mode for 20 hours, power-saving mode for 40 hours (power-saving mode: display screen turned off)
|
charging time
|
<4 hours (can be used for 1 hour after 15 minutes of charging)
|
Support external power supply
|
AC power, 10 - 15 V, I ≈ 500 mA
|
connect opening
|
RS232 interface (can be used for remote control, calibration, and program updates in memory)
|
Software/Memory Programs
|
It can be upgraded through the Internet.
|
self inspect
|
Self check all functions during startup
|
Automatic calibration
|
The probe is equipped with an E ² PROM for real-time automatic zeroing
|
Measuring temperature
|
From -10 to+40 ° C
|
Storage temperature
|
From -20 to+70 ° C
|
Size (WxHxD)
|
108 x 240 x 50 mm
|
weight measure
|
1070g
|
Online inquiry