Precision injection pumpPHD ULTRA CP is the first product of its kind to achieve constant pressure injection. The previous methods for achieving constant pressure injection included a wide variety of signal amplification devices and the use of other external equipment or hardware. The precision injection pump PHD ULTRA CP, on the other hand, only needs to be connected to a pressure sensing/amplification integrated device with a commonly seen 0-10V DC analog output port on the market to easily achieve a constant pressure system and provide up to 1000 pounds of thrust for fluid transfer.
Precision injection pumpThe main features of PHD ULTRA CP are:
1. Support continuous and controllable pressure injection.
2 includes constant pressure mode and constant flow rate mode.
Improve the safety of highly sensitive injection targets and physiological experiments.
4 is compatible with the vast majority of types of pressure sensors.
5 can automatically adjust the flow rate to ensure constant pressure.
A shelf life of up to two years.
Precision injection pumpULTRA CP application:
Short term organ perfusion research that requires maintaining a certain physiological condition
2 Stable and controllable introduction of chemical reactants
3. Eye injection and perfusion
Whole body perfusion of 4 small animals
5 Constant Pressure Microfluidic Mixing Operations
6. Injecting genetic material into organs without viral vectors
Technological innovation of constant pressure precision injection pump
Micro injection pumpPHD ULTRA CP is the first product of its kind to achieve constant pressure injection. The previous methods for achieving constant pressure injection included a wide variety of signal amplification devices and the use of other external equipment or hardware. And this product only needs to be connected to a pressure sensing/amplification integrated device with a commonly seen 0-10V DC analog output port in the market to easily achieve a constant pressure system, providing up to 1000 pounds of thrust for fluid transfer.
Precision injection pumpPHD ULTRA CP's ultra-high performance
useThe patented technology and software controlled pressure monitor of Harvard Apparatus infusion pump, the micro infusion pump PHD ULTRA CP, can control the stability of user-defined pressure within ± 2% range.
A user adjustable sensitivity setting can meet the user's specific requirements for the system response time parameter, which is necessary for achieving the predetermined pressure.
The optional units of pressure provided by the machine areThere are three types: mmHg, KPa, and psi.
Precision injection pumpPHD ULTRA CP pressure and flow rate
Monitoring data can be displayed throughOn the computer connected to the pump via the RS-232 interface. In practical operation, the 0-10V DC analog output port of the pressure sensing/amplification integrated device is connected to the analog input port on the back panel of the pump. Sensors or signal conditioners can be chosen by users themselves, or selected from the numerous sensors and conditioners provided by our company. The range of pressure may be appropriately reduced to comply with the systems of sensors with output voltages less than 10V.
In constant pressure mode, microinjection pumpThe operation screen of PHD ULTRA CP will display the set pressure, actual pressure, and real-time flow rate parameters. Real time flow rate may be a necessary output data in further analysis.
Precision injection pumpPHD ULTRA CP accuracy and repeatability
In addition to constant pressure mode, microinjection pumpPHD ULTRA CP also has high accuracy and repeatability, making it suitable for general constant flow rate modes.
allThe PHD ULTRA CP series microinjection pumps are both injection/suction dual function and programmable.
Technical parameters of PHD ULTRA microinjection pump
model |
PHD ULTRA CP |
PHD ULTRA CP Remote |
PHD ULTRA CP 4400 |
PHD ULTRA CP 4400 Remote |
PHD ULTRA CP Hpsi Remote |
PHD ULTRA XF-CP Remote |
|
type |
Microprocessor, multiple syringes, injection/retrieval, programmable |
Microprocessor, multiple syringes, injection/retrieval, programmable |
Microprocessor, single syringe, injection/aspiration, programmable |
Microprocessor, single syringe, injection/aspiration, programmable |
Microprocessor, multiple syringes, injection/retrieval, programmable |
Microprocessor, multiple syringes, injection/retrieval, programmable |
|
stabilization precision |
±0.25% |
±0.25% |
±0.35% |
±0.35% |
±0.5% |
±0.5% |
|
Pressure Accuracy |
﹤±2% |
﹤±2% |
﹤±2% |
﹤±2% |
﹤±2% |
﹤±2% |
|
Syringe size, minimum/maximum |
0.5 μl to 140 ml |
0.5 μl to 140 ml |
0.5 μl to 140 ml |
0.5 μl to 140 ml |
20 μl to 200 ml |
20 μl to 200 ml |
|
Number of syringes |
2--10 |
2--10 |
1 |
1 |
4 |
4 |
|
Minimum flow velocity |
1.56 pl/min |
1.56 pl/min |
3.06 pl/min |
3.06 pl/min |
50.70 nl/min |
50.70 nl/min |
|
Maximum flow rate |
215.8 ml/min |
215.8 ml/min |
215.8 ml/min |
215.8 ml/min |
144.1 ml/min |
144.1 ml/min |
|
External connection devices | |||||||
USB(Pc to Pump ) |
Type B |
Type B |
Type B |
Type B |
Type B |
Type B |
|
RS--232(Pc to Pump) |
9-Pin D-Sub |
9-Pin D-Sub |
9-Pin D-Sub |
9-Pin D-Sub |
9-Pin D-Sub |
9-Pin D-Sub |
|
|
RS--485( Pump to Pump) |
IEEE-1394, 6 pos |
IEEE-1394, 6 pos |
IEEE-1394, 6 pos |
IEEE-1394, 6 pos |
IEEE-1394, 6 pos |
IEEE-1394, 6 pos |
|
I/O & TTL |
15-Pin D-Sub |
15-Pin D-Sub |
15-Pin D-Sub |
15-Pin D-Sub |
15-Pin D-Sub |
15-Pin D-Sub |
|
Average linear thrust |
34 kg,(75 lbs) at 100% |
34 kg,(75 lbs) at 100% |
91 kg,(200 lbs) at 100% |
91 kg,(200 lbs) at 100% |
200 kg,(433 lbs) at 100% |
454.5kg, (1000bs) at 100% |
|
Maximum pressure# |
50 psi |
50 psi |
135 psi |
135 psi |
290 psi |
670 psi |
|
Control box size, height x width x length |
30.5×21.6×17.8cm (12×8.5×7 in) |
30.5×21.6×17.8cm (12×8.5×7 in) |
30.5×21.6×17.8cm (12×8.5×7 in) |
30.5×21.6×17.8cm (12×8.5×7 in) |
30.5×21.6×17.8cm (12×8.5×7 in) |
30.5×21.6×17.8cm (12×8.5×7 in) |
|
Remote control box size, height x width x length |
N/A |
30.5×14×16.5cm (12×5.5×6.5 in) |
N/A |
30.5×14×17.8cm (12×5.5×7 in) |
30.5×30.5×19.1cm (16.5×12×7.5 in) |
30.5×30.5×19.1cm (16.5×12×7.5 in) |
|
weight |
4.5 kg(10 lb) |
4.8 kg(10.5 lb) |
5.4 kg(12 lb) |
7.7 kg(17 lb) |
13.6 kg(30 lb) |
20.9 kg(46 lb) |
|
Input Voltage |
100--240V AC 50/60 HZ |
100--240V AC 50/60 HZ |
100--240V AC 50/60 HZ |
100--240V AC 50/60 HZ |
100--240V AC 50/60 HZ |
100--240V AC 50/60 HZ |
|