MC122/MC510/MC125PH/ORP controller
By using Miwoqi's MC controller, pH and/or ORP levels can be monitored and controlled.
Miwoqi's MC controller has a user selectable set point and a visual "activation" LED indicator light. When the measured value is higher or lower than the set point, the power controller box opens to control external devices. These MC controllers can ideally control the addition of carbon dioxide and ozone. This possibility is achieved through electromagnetic valve control.
Each controller unit comes with a 12V DC adapter, installation kit, electrodes, electrode holder, and pH calibration solution (ORP calibration is performed at the factory) required for the instrument
A professional pH controller is designed specifically for use in aquariums.
Main features:
Users can set their own high/low alarm control points
Manual 2-point calibration
Visual LED alarm
Provide a 12V DC power adapter and installation kit
• Power plug specifically designed for CO2 injection
• Composite pH electrode and/or ORP electrode platinum (BNC interface)
Specifications
MC122
MC510
MC125
measuring range
0.0 to 14.0 pH
±1000 mV (ORP)
0.00 to 14.00 pH; ±1000 mV (ORP)
resolution
0.1 pH
1 mV (ORP)
0.01 pH; 1 mV (ORP)
accuracy(@25°C)
±0.2 pH
±5 mV (ORP)
±0.2 pH ; ± 5 mV (ORP)
pHalarm point
5.5 to 9.5 pH
4 to 8 pH
ORPalarm point
0 to 600 mV
-200 to 600 mV
call the police
When the measured value is higher than the high alarm point or lower than the low alarm point, an alarm is triggered
When the measured value is higher than the high alarm point or lower than the low alarm point, an alarm is triggered
When the measured value exceeds the high alarm point, an alarm is triggered
Control power start
When the measured value is higher than the high alarm point or lower than the low alarm point, the control power is triggered to turn on(5A max)
When the measured value is higher than the high alarm point or lower than the low alarm point, the control power is triggered to turn on
When the measured value is higher than the high alarm point or lower than the low alarm point, the control power is triggered to turn on
pHelectrode
MA911B/2(included)
MA911B/2(included)
ORPelectrode
MA921B/2(included)
MA921B/2(included)
Usage environment
0-50℃; max RH 95%
0-50℃; max RH 95%
0-50℃; max RH 95%
power supply
12VDC Injector(contain)
12VDC Injector(contain)
12VDC Injector(contain)
Driver power supply
115VAC, 2A, 60Hz or 230VAC, 1A, 50Hz
115VAC, 2A, 60Hz or 230VAC, 1A, 50Hz
115VAC, 2A, 60Hz or 230VAC, 1A, 50Hz
size
148,5 x 82,5 x 32 mm
148,5 x 82,5 x 32 mm
148,5 x 82,5 x 32 mm
weight
180 g (meter only)
180 g (meter only)
180 g (meter only)
MC122/MC510/MC125
Optional accessories:
M10000B: Electrode cleaning solution specification: 20ml/bag (25 bags)
M10004B: PH4.01 standard buffer solution, specification: 20ml, per bag (25 bags)
M10007B: PH7.01 standard buffer solution, specification: 20ml, per bag (25 bags)
M10010B: PH10.01 standard buffer solution, specification: 20ml, per bag (25 bags)
MA9015: Electrode preservation solution specification: 20ml,/bag (25 bags) MA9310:12VDC adapter, 220V
MA9311:12VDC adapter, 110V MA955:1.5m electromagnetic controller
MA911B/2: PH composite electrode, wire length 1 meter MA921B/2: ORP electrode with BNC interface, wire length 2 meters
Ordering information:
Standard configuration:
One MC122 host, one MA9310 12VDC adapter, one MA911B/2 PH electrode, one bag (20ml) of PH4.01 calibration solution, one bag (20ml) of PH7.01 calibration solution, one calibration tool, and one instruction manual.
One MC510 host, one MA9310 12VDC adapter, one MA921B/2 ORP electrode, and one instruction manual.
One MC125 host, one MA9310 12VDC adapter, ozone injection power plug socket, one MA911B/2 PH electrode, one MA921B/2 ORP electrode, one bag of PH7.01 calibration solution (20ml), one calibration tool, and one instruction manual