English

Yongjia County Marine Water Pump Factory
Home>Products>PF/FP polypropylene plastic corrosion-resistant pump
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    13676799385
  • Address
    No. 245 Linxia Road, Zhangbao Industrial Zone, Sanqiao Industrial Park, Wenzhou
Contact Now
PF/FP polypropylene plastic corrosion-resistant pump
PF/FP polypropylene plastic corrosion-resistant pump is a corrosion-resistant plastic centrifugal pump with small volume, high efficiency, beautiful s
Product details

Model Meaning

PF/FP聚丙烯塑料耐腐蚀泵型号意义

Product Introduction
PF/FP polypropylene plastic corrosion-resistant pump is a corrosion-resistant plastic centrifugal pump with small volume, high efficiency, beautiful shape, and reasonable structure.
The self-priming function of PF/FP polypropylene plastic corrosion-resistant pump overcomes the fatal disadvantages of plastic pumps caused by water interruption, lack of water intake, and seal heating and burning of plastic parts, greatly improving the service life of the pump.
PF/FP polypropylene plastic corrosion-resistant pump overcurrent components are made of ABS, PP and other plastics, suitable for industries such as food water purification and chemical engineering. For decades, it has been a necessary supporting equipment for water treatment and chemical industries. Our company adheres to high-quality products and continuously improves product performance, which has been well received and favored by a wide range of users. We welcome more new and old customers to inquire and place orders.
FP energy-saving and corrosion-resistant centrifugal pump, FP (Z) self-priming pump, using polyvinylidene fluoride (PVDF) and reinforced polypropylene (CFR-PP) one-time injection molding. High mechanical strength, strong corrosion resistance, and unique scientific structure of self-priming pumps. The pump chamber is equipped with a suction chamber, a storage chamber, a return check valve, a gas-liquid separation chamber, and a return hole. Just need to inject the liquid before the first opening, and there is no need to repeat the injection in the future. When suctioning the medium, the liquid can be intermittent. Within 15 minutes of interruption, the liquid can continue to be suctioned. The mechanical seal does not require additional cooling water, and is easy to operate, safe, and leak free. It is an ideal product to replace the submersible pump.
PVDF material: Good airtightness, non-toxic, pollution-free, anti oxidative and anti-aging, good mechanical properties, resistant to strong oxidants, halogens, aromatic solvents, working temperature -40~120 ℃.
CFR-RP material: non-toxic, non polluting, resistant to general acid, alkali and salt, working temperature -14~80 ℃

Product Features
It has the advantages of small size, light weight, simple structure, convenient use, high efficiency, and low price. The inner cavity of the pump body is smooth, the impeller is closed, and two types of mechanical seals and rubber ring seals are used. The entire shaft is made of stainless steel and connected with a sleeve.

application
Mainly used for transporting corrosive liquids such as acids, bases, salts, etc., but not for transporting chemicals that have a significant effect on engineering plastics, such as aromatic hydrocarbons, halogenated derivatives of fatty hydrocarbons, ketones, and concentrated acids and bases.

Structural diagram

PF/FP聚丙烯塑料耐腐蚀泵结构图
Serial Number
name
1
case of pump
2
Impeller shaft assembly
3
mechanical seal
4
pump cover
5
electrical machinery

Performance Curve

102/103/104/105塑料化工泵曲线图

performance parameter

product name
model
Caliber mm
Flow rate (m3/h)
Head (mm)
Power (KW)
Speed (r/min)
Suction distance (m)
Voltage (V)
Import
Export
101 Plastic Centrifugal Pump
FP(FS)65-50-150
65
50
20
25
4
2840
5.5
380
102 plastic centrifugal pump
FP(FS)40-32-125
40
32
12.5
20
1.5
2900
6
380
103 plastic centrifugal pump
FP(FS)32-25-105
32
25
6.3
8
0.75
2900
6
380
104 plastic centrifugal pump
FP(FS)32-25-100
32
25
4
7
0.55
2900
6
220
101.5 Plastic Centrifugal Pump
FP(FS)50-40-130
50
40
20
17
2.2
2900
3
380
105 plastic centrifugal pump
FP(FS)20-15-100
20
15
6.5
6.5
0.37
2900
3
220 380

Installation size

size
A
B
C
D
E
F
G
name
model
101 Plastic Centrifugal Pump
FP(FS)65-50-150
610
340
65
50
190
140
152
102 plastic centrifugal pump
FP(FS)40-32-125
500
250
40
32
140
100
120
103 plastic centrifugal pump
FP(FS)32-25-105
400
240
32
25
120
90
110
104 plastic centrifugal pump
FP(FS)32-25-100
400
240
32
25
120
90
110
101.5 Plastic Centrifugal Pump
FP(FS)50-40-130
510
250
50
40
140
120
120
105 plastic centrifugal pump
FP(FS)20-15-100
380
120
20
15
120
90
110
1. PF/FP polypropylene plastic corrosion-resistant pumps should be installed horizontally, and the pump body should not bear the weight of the pipeline. For special requirements for vertical installation, the motor must be facing upwards.
2. The pump body must be filled with water before use. When the suction liquid level is higher than the pump axis line, open the suction pipeline valve before starting. If the suction liquid level is lower than the pump axis line, the pipeline needs to be equipped with a bottom valve.
3. Before starting the motor, check whether its rotation direction is consistent with the pump direction mark.
4. The conveyed medium and temperature should be within the allowable range of the pump material (see attached table). The operating temperature of plastic chemical pumps should be ≤ 60 ℃, the temperature rise of the motor should not exceed 75 ℃, and the ambient temperature should be ≤ 40 ℃.

Corrosion resistance of materials

medium
concentration
CFR-PP
medium
concentration
25℃
65℃
90℃
20℃
60℃
80℃
Sulfuric acid H2SO4
98%
Sulfuric acid H2SO4
<30%
X
70%
30~70%
X
1~50%
>75%
X
X
Nitric acid HNO3
concentrated
Nitric acid HNO3
10%
20%
20%
10%
25~35%
>50%
X
X
Hydrochloric acid HC1
0~30%
X
Hydrochloric acid HC1
>30%
X
hydrofluoric acid
X
X
hydrofluoric acid
>10%
X
40~48%
X
acetic acid
1~50%
acetic acid
>20%
phosphoric acid
Various concentrations
phosphoric acid
>30%
X
X
sodium hydroxide
sodium hydroxide
Chlorinated steel
Chlorinated steel
X
Chlorinated steel
ethanol
ethanol
bleaching solution
bleaching solution
X

Fault causes and troubleshooting methods

Fault
reason
Troubleshooting
The pump cannot produce liquid
1. Pump reversal
2. Leakage in the inlet pipeline
3. There is too little liquid stored in the pump chamber
4. The suction distance is too high
5. Bottom valve leakage
6. Impeller obstructed and unable to rotate
1. Change the motor wiring
2. Eliminate air leakage
3. Increase the storage position
4. Lower the installation position of the pump
5. Clean the bottom valve
6. Clean the pump casing and impeller
Insufficient traffic
1. The suction pipe diameter is too small
2. Impeller channel blockage
3. Head too high
4. There is air leakage in the suction pipeline
5. Damaged impeller
1. Replace the liquid inlet
2. Clean the impeller
3. Turn up the outlet valve
4. Eliminate air leakage
5. Replace the impeller
Low head
1. Excessive traffic
2. The speed is too low
1. Turn down the outlet valve
2. Restore rated speed
Low noise level
1. There are debris inside the pump
2. Friction between rotating parts and fixed parts
3. Severe wear of the shaft
1. Check and clean
2. Adjust the gap
3. Replace the pump shaft
Leakage of liquid
1. Loose fixing screws of pump casing
2. Severe wear of mechanical seal
1. Tighten the screws
2. Replace the mechanical seal

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!