Standard PROFIBUS-DP slave interface, compliant with IEC61158 TYPE3 PROFIBUS international standard and Chinese national standard GB/T 20540-2006;
● Baud rate adaptive 9600-12Mbps;
● Compatible with mainstream PROFIBUS master station equipment, such as Siemens 300/400 PLC, Beckhoff dp master station ABB 800F、 Omron main station, Hollysys LK PLC, Hollysys DCS, etc;
The CAN2.0A/2.0B interface complies with the CANopen CiA D raft Standard 301 standard;
Through the configuration and programming of the main station (PLC), CAN and CANopen protocol communication can be flexibly implemented;
Provide product GSD files for PROFIBUS network integration; The CAN communication baud rate can be selected through the main station configuration (such as in STEP7 configuration); 5K, 10K, 20K, 40K, 50K, 80K, 100K, 125K, 200K, 250K, 400K, 500K, 666K, 800K, with 'control word and status word' settings, can control the device's status in real time, meet user specific needs 1M optional.
Memory sharing gateway, the PROFIBUS master station reads/writes CANopen side station data directly based on the configured gateway PROFIBUS data area (I/Q area). The gateway GSD file is used for network integration, and CANopen configuration can be achieved through the main station configuration, providing the corresponding relationship between PROFIBUS I/Q and CANopen site data;
PB-B-aCANCharacteristics of Bus Bridge
●PB-B-aCANThe bus bridge has two working modes: M0/M1Working mode.M0The mode bus bridge can be usedCANMaster or slave station;M1The mode can only doCANMain station;
●M0The working mode needs to be inPROFIBUSMain station configuration (such asSTEP7)Configure the bus bridge in the middleCANCommunication parameters, such as baud rate, etc. The implementation of free protocols relies on the main stationPLC/DCSProgramming, transmissionCANMessage data toPROFIBUSoutputQZone, programming control bus bridge control sub, implementing eachCANreportInitiate the sending of the text and proceed fromPROFIBUSinputIGet the bus in the areaCANReceive message data.
●M1The only difference in working mode is that it requiresPROFIBUSMain station configuration (such asSTEP7)Configure the gateway in the middleCANopenCommand queue to be sent (Various)TPDO、RPDO,SDO、SYNC、NMT、Heartbea t)And nodesIDThe gateway can automatically generate and send (timed, triggered) information such as transmission intervalsCANMessage and receive parsing commands and data from the slave station.
●The status word of the bus bridge can comprehensively reflect the communication status of the bus bridgeCANThe communication status and control word can flexibly control the sending and receiving logic.
|
|
PB-B-aCAN |
|
PROFIBUS parameters |
standard |
conform toIEC61158 TYPE3 PROFIBUSInternational standards, Chinese national standardsGB/T 20540-2006. |
|
speed |
Baud rate adaptive, 9200~12Mbps |
||
Data volume |
PROFIBUS input/output quantity can be freely set, maximum input/output: <3> Max Output Bytes ≤ 196 Bytes; |
||
CAN interface parameters |
can protocol |
ISO11898 CAN2.0A |
ISO11898 CAN2.0B |
physical interface |
Standard CAN driver interface isolation |
||
frame format |
Standard frame: 11 bit ID |
Extended frame: 29 bit ID |
|
Master/Slave working mode |
M0mode:Master, from M1 mode:Master, from Dial switch setting |
M0pattern:Master, from M1 mode:Master, from Dial switch setting |
|
Baud rate |
5K, 10K, 20K, 40K, 50K, 80K, 100K, 125K, 200K, 250K, 400K, 500K, 666K, 800K, 1Mbps optional |
||
Operational characteristics |
|||
collocation method |
● pass throughDPMain station configuration gateway
● M0The working mode needs to be inDPMain Station(STEP7)Configure the bus bridge in the middleCANCommunication parameters, such as baud rate, etc. ByDPMain Station(PLC/DCS)Programming to controlCANData transmission and reception, implementing free protocolsCANCount toPROFIBUSThe conversion.
● M1The working mode needs to be inDPMain Station(STEP7)Configure the bus bridge in the middleCANCommunication parameters, such as baud rate, are inserted by inserting different onesIO moduleAnd set different settingsIDNumber and receiving/sending length to be confirmedCANData transmission and reception. ● M1The mode can be configured at most24stripCANinstruction,Can be applied to eachCANMonitor the status of the equipment. |
||
GSD file | M0:DSCANM0.GSD M1:DSCANM1.GSD | M0:DSCANM0.GSD M1:DSCANM1.GSD | |
Electrical parameters |
power consumption |
Power supply: 24VDC (± 20%), current: 110mA (at 24VDC) |
|
authentication |
CE certification, PROFIBUS certification |
||
Temperature and humidity |
Working temperature: -20 ℃~+55 ℃ (for customers with lower temperature requirements, please make a purchasing statement); Transportation and storage: -40 ℃ to+70 ℃; Relative humidity at work: 5~95% (no condensation) |
||
installway |
Method: 35mm guide rail |
||
protection grade | IP20 | ||
weight | About 230g | ||
External dimensions | Dimensions: Width (70mm))×Length (112.5mm) × Thickness (39.5mm) | ||
Product Features |
Application scenarios |
<1>PB-B-aCANFor various purposesCAN2.0A/2.0BFree protocol (user-defined orJ1939Equipment accessPROFIBUSBuses provide flexible and convenient solutions. <2>M0、M1The mode is more suitable for system integration engineers, and configuration work needs to be completed in the main station configuration work,M0needPLCImplement various free protocols through programming,M1compareM0Programming is simple. |
Outline and Device Layout of PROFIBUS Bus Bridge
Outline dimensions and installation of PROFIBUS bus bridge
Industry Applications
Wind power industry: Inner Mongolia wind farm, Zhangbei wind farm
Port Machinery: Sany Heavy Industry
Coal mining industry: Yangquan Coal Mine
Metallurgical industry: industrial furnace equipment
Plastic Machinery: Hangzhou in HeshunBOPETApplication in film production line
PB-B-aCAN2.0A GSD file
PB-B-aCAN Function Selection Switch Description
PB-B-aCAN (2.0B-M0 mode) GSD file
PB-B-aCAN (2.0B-M1 Mode) Product Manual
PB-B-aCAN (2.0B-M0) Product Manual
PB-B-aCAN (2.0A-M1) Product Manual
PB-B-aCAN (2.0A-M0) Product Manual