Jinhu Zhenke Instrument Co., Ltd
Home>Products>Ordinary side mounted magnetic level gauge
Ordinary side mounted magnetic level gauge
UHZ-517/C ordinary side mounted magnetic level gauge can be used for medium level detection of various equipment such as towers, tanks, spherical cont
Product details

UHZ-517/C ordinary side mounted magnetic level gaugeIt can be used for medium level detection of various towers, tanks, spherical containers, boilers and other equipment. This series of magnetic level gauges can achieve high sealing, leak prevention, and adapt to liquid level measurement under high pressure, high temperature, and corrosive conditions, with reliable safety. It compensates for the shortcomings of glass tube level gauges, such as unclear indication and easy breakage, and is not affected by high and low temperature fluctuations. It does not require the combination of multiple sets of level gauges. The entire measurement process has no blind spots, with clear display, intuitive readings, and a large measurement range. Especially in the on-site indication section, as it does not come into direct contact with liquid media, its superiority is even more evident for high temperature, high pressure, high viscosity, toxic and harmful, and highly corrosive media. Therefore, it is more reliable, safe, progressiveness and practical than the traditional glass tube and plate level gauge.
The most significant feature of the side mounted magnetic flip column level gauge is that the liquid medium is completely isolated from the indicator, making it very safe, reliable, and durable in any situation. Moreover, various models of level gauges are equipped with level alarms and control switches, which can achieve upper and lower limit alarms, control, or interlocking of the liquid level or boundary; Equipped with a static pressure level transmitter or a dry spring resistance level transmitter, the liquid level and boundary signals can be converted into a two-wire 4-20mADC standard signal, enabling remote indication, detection, recording, and control. This series of side mounted magnetic flip column level gauges can be widely used for level measurement and control in various industries such as power, petroleum, chemical metallurgy, environmental protection, shipbuilding, construction, and food production processes.
Technical Parameter

Measurement range: 300-15000mm
Accuracy: ± 10mm, ± 16mm
Flip column diameter: 10mm, 16mm
Working pressure: ≤ 2.5Mpa (can be designed separately for 2.5Mpa and above) Anti corrosion type ≤ 0.6Mpa
Medium density: ≥ 0.45g/cm3
Medium density difference: ≥ 0.15g/cm3 (measurement boundary)
Medium density: -20 ° C+250 ° C (special requirements can reach 450 ° C)
Medium viscosity: ≤ 0.4PaS. For high viscosity media or media that are prone to crystallization at low temperatures, a heated jacket type liquid level gauge can be selected according to user requirements.
Environmental vibration: frequency ≤ 25Hz, amplitude ≤ 0.5mm
Follow speed: ≤ 0.08m/s
Factory connection flange size: DN25, PN1.0 (metric pipe)
Connecting flange: Adopting the latest HG20592-20635-97 flange standard issued by the Ministry of Chemical Industry in 1998. If other flange standards (such as GB, ANSI, DIN, etc.) are used, please indicate when ordering. For the connection flange of high-pressure side mounted magnetic level gauge, HG20595-97 neck butt welding connection flange DN25, PN6.0 or PN10Mpa shall be used, and the sealing surface shall be raised or convex. If there are special requirements, they can be specified when ordering.
Please refer to the relevant content of this sample for the main technical parameters of the remote transmission supporting instruments. If there are special requirements, they can be discussed during the ordering process.

Structural principle

The liquid level gauge is developed based on the principle of buoyancy and magnetic coupling. When the tested container When the liquid level in the middle rises or falls, the magnetic float in the liquid level gauge body tube also rises or falls accordingly The permanent magnetic steel inside is transmitted to the magnetic flip column indicator through magnetic coupling, driving the red and white flip columns flip180°When the liquid level rises, the flip column changes from white to red, and when the liquid level drops The flipping column changes from red to white, and the red white boundary of the indicator represents the actual liquid level inside the container To achieve clear indication of liquid level by adjusting the height.

Specification and model

Series
Model
UHZ-517

Structural characteristics

Liquid receiving material

measuring range
mm

Applicable medium conditions

Flange connection mm

Weight kg

temperature

pressure
Mpa

density
g/cm
3

Viscosity
Pa.s

DN

PN

basic
weight

lengthening
basic
weight

C10

Standard type

1Cr18Ni
9Ti0Cr18Ni9
304

300-
8000

-20
+150

0-2.45

0.5-2

≤0.04

25

1.0
1.6

6

5

C11

High pressure

300-
8000

-20
+150

2.45-9.6

0.5-2

≤0.04

25

2.5
4.0

6

6

C12

High temperature type
High pressure

300-
8000

-20
+350

2.45-9.6

0.5-2

≤0.04

25

6.3
1.0

6

6

C13

Low temperature model
Frost proof type

300-
3500

>-40

0-2.45

0.5-2

≤0.04

25

1.6
2.5

6

7.5

C14

Liquid ammonia, liquid
Fossil oil and gas
specialized

300-
15000

-20
+150

0-2.45

0.45-0.7

≤0.05

25

2.5

6.5

6

C15

anti-corrosive

00Cr17Ni14Mo2
316L

300-
8000

-20
+150

0-2.45

0.5-2

≤0.04

25

1.6

6

5

C16

Anti corrosion type(
PP outer layer glass
Fiberglass steel

PP

300-
5000

20
+100

0-0.6

0.5-2

≤0.04

32

1.6

3

3

C17

Anti corrosion type(
PVC outer layer
Fiberglass reinforced plastic

U-PVC

300-
5000

20
+60

0-0.5

0.5-2

≤0.04

32

1.6

3

3

C18

Anticorrosive type

ABS

300-
5000

-20
+120

0-0.6

0.5-2

≤0.04

32

1.0

3

3

C19

Anti corrosion type(
Stainless steel interior
Lined with PP

PP

300-
15000

-20
+100

0-1.0

0.5-2

≤0.04

25

1.6

4

5

C20

Anticorrosive type

PE

300-
5000

20
+40

0-0.6

0.5-2

≤0.04

25

1.6

6

7

C21

Steam jacket
Heating type

1Cr18Ni9Ti

300-
15000

-20
+150

0-2.45

0.5-2

≤0.05

32

1.6

6

8

C22

high viscosity
Medium type

0Cr18Ni9
304

300-
15000

-20
+150

0-2.45

0.5-2

≤0.05

32

1.6

6

5

C23

Food Specialty
Usage type

1Cr18Ni9Ti

300-
15000

-20
+150

0-1.6

0.5-2

≤0.05

50

1.6

7

5

Content of supporting instruments and accessories

UHZ-517C□□

O

Blind flange, without drain valve

L

Bottom of the liquid level gauge is equipped with a drain valve

O

No liquid level alarm switch

H

High level alarm switch AK-3 type, with memory function, failure to troubleshoot, signal not eliminated

L

Low level alarm switch AK-4 type, with memory function, failure to troubleshoot, signal not eliminated

B

High and low alarm switches are fully equipped, with memory function for AK-3 and AK-4 models

G

High level alarm switch, regional alarm AK-1 type

One DF-1 type conversion amplifier is attached
One PF113A socket




JTX-012-22F high-power relay (single point: one, double point: two) PF083A socket

D

Low level alarm switch, regional alarm AK-1 type

Q

High and low alarm switches are fully equipped, with two AK-1 regional alarms

S

Integrated high and low position alarm switch, regional alarm AK-2 type

O

No liquid level control switch

H

Upper limit control switch, single point spring CK-1 type

L

Lower limit control switch, single point spring CK-1 type

B

Fully equipped with upper and lower limit control switches, single point dry spring CK-1 type two sets

W

Integrated upper and lower limit control switches, dual point spring CK-2 type

T

Upper limit control switch, Hall sensor CK-3 type

L

Lower limit control switch, Hall sensor CK-4 type

E

Fully equipped with upper and lower limit control switches, Hall sensor CK-3 type two sets

C

Integrated upper and lower limit control switches, Hall sensor CK-4 type

O

No remote transmission transmitter device

R

Equipped with BOS2088 bundled transmitter, output two-wire 4-20mADC

S

Static pressure remote transmitter, (URS-100) output two-wire 4-20mADC

O

Ordinary waterproof type

B

Inherent safety type IB Ⅱ CT4, can be equipped with Zener safety barrier or IS4041 Ex isolation barrier

Bd

Explosion proof type d Ⅱ CT4

O

Not suitable for remote transmission display instrument

A

Digital and light column display adjustment alarm XMGT (vertical)

B

Digital and light column display adjustment alarm XMGT (horizontal)

<,/P>

C

Digital display adjustment alarm XMT (horizontal)

E

Dual column liquid level display instrumentXMGT(Vertical)

D

Intelligent liquid level/capacity (weight) display regulator XMT (horizontal)

-□□□□

Measurement range mm

-□□

Medium density g/cm3

-

D

Open pressure container

Working pressure MPa

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!