Qingdao Xincheng Environmental Protection Technology Co., Ltd
Home>Products>OIL -6 Infrared Spectrophotometer | Infrared Oil Analyzer
Product Groups
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    18553291905
  • Address
    No. 77 Chaoyangshan Road, Huangdao District, Qingdao City
Contact Now
OIL -6 Infrared Spectrophotometer | Infrared Oil Analyzer
OIL -6 Infrared Spectrophotometer | Infrared Oil Analyzer
Product details

OIL -6 Infrared Spectrophotometer | Infrared Oil Analyzer

1、 Instrument Introduction:
The OIL -6 infrared oil analyzer is a new type of oil analyzer designed based on the principle of infrared spectrophotometry and in accordance with the requirements of GB/T16488-1996. When connected to a computer, the instrument can display the position of spectra and absorption peaks, and can quickly and accurately measure the oil content in water. It is widely used in industries such as petroleum, chemical, scientific research, and environmental monitoring.
► Infrared oil analyzer, using infrared spectrophotometry for measurement, can display and print the spectral and absorption peak wavenumber positions of the sample after spectral scanning. It can quickly and accurately measure the total concentration of oil in water. Main application areas: The infrared oil analyzer is not only suitable for monitoring the content of petroleum (mineral oil), animal and vegetable oils, and total oil in various water bodies and soils such as surface water, groundwater, seawater, domestic water, and industrial wastewater, but also recommended by the national standard for monitoring the oil content in flue gas (cooking fumes in the catering industry). In addition, it can also be used for purity detection of organic reagents and measurement of the total amount and amount of organic compounds containing various C-H bonds.
Traditional component analysis involves sampling first and then measuring qualitatively, which takes a long time and cannot obtain measurement data in a timely manner. And the molecular functional groups of most substances can absorb infrared light, making it easy to conduct qualitative analysis and quantitative calculation of internal components through the absorption and conversion of spectral energy. The infrared oil analyzer is based on this principle and uses infrared spectrophotometry for measurement. After scanning the spectrum of the sample, it can display and print the spectral and absorption peak wavenumber positions of the sample. It can quickly and accurately measure the total concentration of oil in water.
The definition of petroleum is: a substance extracted with CCl4 under the conditions specified in the standard "GB/T16488-1996", which is not adsorbed by magnesium silicate and has characteristic absorption at all or part of the spectral bands with wave numbers of 2930cm-1, 2960cm-1, and 3030cm-1. The definition of animal and vegetable oils is: substances extracted with CCl4 under the conditions specified in the standard GB/T16488-1996 and adsorbed by magnesium silicate. According to the recommended methods of the International Organization for Standardization (ISO), China has formulated and promulgated the national standard "Determination of Water Quality for Petroleum and Animal and Vegetable Oils by Infrared Spectroscopy" (GB/T 16488-1996) based on infrared photometry. This standard includes two methods, infrared spectrophotometry and non dispersive infrared spectrophotometry, but currently in China, most of them use infrared spectrophotometry. Recently, the country issued the "Determination of Water Quality, Petroleum and Animal and Vegetable Oils by Infrared Spectroscopy" (HJ637-2012) standard. The traceability experiment personnel compared the experimental analysis using two standard methods and proved that the accuracy and precision of the infrared oil analyzer produced by our company meet the requirements. The non dispersive infrared photometry method in this standard has been abolished.
2、 Application areas:
The infrared oil analyzer is not only suitable for monitoring the content of petroleum (mineral oil), animal and vegetable oils, and total oil in various water bodies and soils such as surface water, groundwater, seawater, domestic water, and industrial wastewater, but also recommended by the national standard for monitoring the oil content of flue gas (cooking fumes in the catering industry). In addition, it can also be used for purity detection of organic reagents and measurement of the total amount and amount of organic compounds containing various C-H bonds.
3、 Instrument parameters:
1. Detection limit:<0.12mg/L (CCl4 extract, measured directly with a 5cm quartz colorimetric dish)
<0.0012mg/L (water sample, using extraction ratio of 100:1, 5cm quartz colorimetric dish)
2. Repeatability: ≤ 1% (for 20mg/L oil sample)
3. Linear: R>0.999
4. Wave number range: 3400cm-1 to 2400cm-1
5. Absorption range: 0.0000-3.000AU
6. Basic measurement range: 0.12 mg/L to 100mg/L (CCl4 extract, 5cm colorimetric dish)
0.0012mg/L~10000mg/L (for water samples, the lowest concentration is measured using an extraction ratio of 100:1 and a 5cm quartz colorimetric dish, while the highest concentration is measured using a 0.5cm quartz colorimetric dish)
7. Dimensions: 550mm × 380mm × 150mm
8. Weight: 15Kg
9. Power supply: (220 ± 22) V (50 ± 1) Hz 35VA
4、 Product features:
1. The detachable integrated optical system has a small instrument volume, light weight, and first separates and then absorbs, which meets the requirements of infrared spectroscopy. It has good stability and high signal-to-noise ratio.
2. By using electrically modulated light sources, the heating intensity of the light source is reduced to facilitate system heat dissipation. At the same time, due to the absence of mechanical cutting motion components, the instrument structure is simplified and the reliability of the instrument is improved.
3. The sensor signal processing adopts a phase-locked amplifier circuit, which improves the instrument's signal-to-noise ratio and minimum detection limit.
4. Unique colorimetric cell structure design, suitable for any colorimetric dish ranging from 1 to 5 centimeters.
5. The structure is simple, and the optical and electrical systems of the instrument are self-contained, with a high degree of integration, thereby improving the reliability and maintainability of the instrument.
6. Easy to operate, just click the mouse to complete one oil sample measurement.
7. Fast measurement speed, it only takes 1 minute to measure a sample once.
8. The software has powerful functions such as automatic zeroing and regression equation calculation. Measurement data and spectra can be saved to the hard drive, and spectra can be queried and printed at any time.
5、 Other:
The instrument consists of an optical system, an electrical system, a microcomputer, and a data processing system.
1. The optical system consists of a light source, a collimating objective, a reflector, a colorimetric cell, a grating, an imaging objective, a filter, a pyroelectric detector, etc.
2. The host electrical system includes modulation light source circuit, stepper motor drive circuit, wavelength positioning circuit, signal amplification processing circuit, analog-to-digital conversion circuit, single-chip microcomputer system, etc.
3. The microcomputer controlled data processing system includes control software, measurement software, data processing software, file management, printing reports, and other parts.
► Instrument storage and usage conditions:
1. Environmental temperature: 10 ℃~35 ℃
2. Relative humidity not exceeding 80%
3. The instrument should be placed in a laboratory that is free of corrosive gases, strong electromagnetic interference, well ventilated, and dust-free.
4. Power supply: (220 ± 22) V AC 50Hz
5. Areas with unstable power supply should be equipped with regulated power supply.
6. The power supply should be well grounded.
► Transportation and storage:
1. The product should be stored at a temperature of 5-35 ℃ and a relative humidity not exceeding 80% under its original packaging conditions.
2. During transportation, instruments should avoid strong vibrations and collisions.
6、 Product configuration
1. 1 oil measuring instrument host

2. 2 4cm colorimetric dishes

3. 1 power cord for the host

4. 1 RS232 data communication cable

5. 1 CD for program installation

6. 1 spare tungsten lamp

7. 1 copy of instruction manual

8. 1 certificate of conformity

9. 1 warranty card

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!