Extended functionality
Secondary pressure drop test

Main indicators
>Voltage 0-500V>current 0.05A-10A
>Phase 0-360 degrees>frequency 45-55Hz
>Harmonic 2-51st>accuracy level 0.05

Main features
1. Adopting a 10.2-inch color LCD display screen, operated by a touch screen, all detection parameters are displayed on one screen with full information and a large amount of information;
2. On site inspection of single-phase/three-phase electronic and inductive active and reactive energy meters; Single phase electronic and inductive energy meters can also be inspected on-site;
3. Verification of primary and secondary meters: Simultaneously measure the error and energy accumulation function of active, reactive, or two energy meters;
4. Wiring simulation function: It can simulate various wiring on site without connecting voltage and current signals, and obtain corresponding wiring results;
5. Electrical parameter measurement: voltage/current/active power/reactive power/phase/frequency/power factor and other parameters, and display dynamic hexagonal vector diagram;
6. Automatic wiring discrimination, measuring various wiring methods, displaying wire inspection results, calculating correction factors for power replenishment;
7. 5A clamp error self check, measure the error of the clamp gauge, and keep track of the closure status of the clamp gauge at any time;
8. Real time measurement of waveforms of A, B, and C three-phase voltage and current, as well as 2-51st harmonic bar charts, to timely understand the power supply quality of the power grid;
9. In high supply and high timing, the wiring can also be recognized without load, with a minimum starting current of 2mA;
10. There is no adjustable resistor inside the instrument, and all errors are corrected using software;
11. Chinese input: Chinese input supports Chinese character input methods such as Pinyin, Wubi, and Wubi strokes;
12. The electric energy accumulation function can be used to verify electric energy meters without electric energy pulse output, or as a test for energy-saving indicators;
13. PT secondary load online testing, detecting secondary voltage, current, phase, and admittance;
14. CT secondary load online testing, detecting secondary voltage, current, phase, and impedance;
15. Multiple power sources: direct power supply for the measuring end, external socket power supply, high-performance lithium battery power supply;
16. Large font display, clear and intuitive screen for remote observation;
17. Equipped with a clamp meter of 500A or above, directly measure the transformation ratio of low-voltage current transformers and the comprehensive error of low-voltage measuring devices;
18. It can download data for 5000 users, and all on-site parameters and downloaded data can be freely defined by users;
19. Equipped with a USB interface, it can be connected to a USB flash drive to create a super large space for easy data copying;
20. Support barcode scanning gun, automatically enter energy meter code, read meter asset number and lead seal number, etc. (optional function);
21. Infrared light bulb and 485 interface, automatically reading multifunctional energy meter and terminal data (optional function);
22. Optional secondary pressure drop testing function.

Product Usage
1. Electrical parameter measurement (U/I/Φ/P/Q/S/PF/Hz);
2. Discrimination of load characteristics between inductive and capacitive circuits;
3. Test the power consumption/power consumption of electrical equipment;
4. Single and three-phase power error verification;
5. Comprehensive measurement of low-voltage measuring devices;
6. Load curve recording and online monitoring of load fluctuations;
7. Can be equipped with a high current clamp meter for power line loss management data collection;
8. Measurement of electricity quality in the power grid;
9. Check the wiring of household meters and prevent electricity theft.

Technical indicators
1. Voltage measurement: 30-480V, resolution 0.001V, accuracy ± 0.05% RD
2. Current measurement: Terminal measurement (0.1~10A) with a resolution of 0.0001A and an accuracy of ± 0.05% RD
5A clamp gauge measurement (overload 10% In-200% In), accuracy ± 0.2% RD
3. Active power measurement
Direct measurement: voltage 30V~480V, current 0.1A~10A, accuracy ± 0.05%
Voltage 30V~480V, current 0.01A~0.1A, accuracy ± 0.1%
Clamp meter measurement: voltage 30V~480V, current 10% In~200% In, accuracy ± 0.2%
4. Reactive power measurement
Direct measurement: voltage 30V~480V, current 0.1A~10A, accuracy 0.1%
Voltage 30V~480V, current 0.01A~0.1A, accuracy 0.2%
Clamp meter measurement: voltage 30V~480V, current 10% In~200% In, accuracy 0.5%
5. Phase measurement
Phase measurement range: 0 °~359.99 ° resolution 0.01 °
Direct measurement: voltage 30V~480V, current 1A~10A, accuracy 0.05 °
Voltage 30V~480V, current 0.01A~0.1A, accuracy 0.1 °
Clamp meter measurement: voltage 30V~480V, current 10% In~200% In, accuracy 0.5 °
6. Frequency measurement
Frequency measurement range: 45Hz~65Hz, resolution: 0.001Hz, accuracy: 0.01Hz
7. Power factor measurement
Power factor measurement range:- 1.0~0~+1.0
Direct measurement: voltage 30V~480V, current 0.1A~10A, accuracy: 0.0005
Clamp meter measurement: voltage 30V~480V, current 10% In~200% In, accuracy: 0.002
8. Active energy measurement
Direct measurement: voltage 30V~480V, current 0.1A~10A, accuracy: 0.05%
Voltage 30V~480V, current 0.01A~0.1A, accuracy: 0.1%
Clamp meter measurement: voltage 30V~480V, current 10% In~200% In, accuracy: 0.2%
9. Reactive energy measurement
Direct measurement: voltage 30V~480V, current 0.1A~10A, accuracy: 0.1%
Voltage 30V~480V, current 0.01A~0.1A, accuracy: 0.2%
Clamp meter measurement: voltage 30V~480V, current 10% In~200% In, accuracy: 0.5%
10. Electric pulse output
Electric energy output pulse constant (r/kwh) Low frequency pulse: 3600 pulses/kwh; High pulse: 3.6X107/pulse/kwh
11. Electric energy pulse input
The pulse constant (r/kwh) of the calibrated electric energy meter is set within the range of 1 to 99999
12. Operating environment: Temperature: -15 ℃ -45 ℃, Humidity: ≤ ± 85% RH, non corrosive gas
13. Power supply: PT borrowed AC 80-480V, power consumption ≤ 7.5VA
Socket power supply AC220V mains power, lithium battery power supply, working time>8 hours
14. Volume: 370 × 265 × 140 (mm), weight 4.5 kg

PT load measurement range (standard):
Voltage 100V, admittance 0.1-99.99 mS, impedance 10-10000 ohms
Voltage 57.7V, admittance 0.17-173.3mS, impedance 5.77-5770 ohms

CT load measurement range (standard):
When the current is 10A, the admittance is 20.8-50000mS and the impedance is 0.02-48 ohms
When the current is 10mA, the admittance is 0.021-50mS and the impedance is 20-48000 ohms

Secondary pressure drop technical indicators (optional function):
1. Measurement range: Differential ratio: 0.000~±10.00%
2. Angle difference: 0.000 to ± 10800 minutes (180 degrees)
3. Pressure drop: 0.000-14.14%
4. Frequency: 50.00 ± 0.5Hz
5. Initial voltage range: (100/√ 3 ± 20%) V, (100 ± 20%) V
6. Accuracy: Deviation<0.01%
7. Angle difference:<0.5 points
8. Working power supply: AC80-260V power consumption<3W;
Configuration Details
1. Standard configuration details:
1) 1 host
2) 3 5A clamp current transformers
3) 1 USB flash drive (4G)
4) 1 set of voltage and current testing wires
5) 1 set of multifunctional photoelectric sampler
6) 1 pulse input/output line
7) 1 power adapter
8) 1 correction ring
9) 1 socket power cord
10) 1 copy of user manual
11) 1 copy of factory inspection report
12) 1 copy of factory certificate/warranty card
13) 1 toolkit

2. Details of selected accessories:
1) 100A clamp current transformer
2) 500A clamp current transformer
3) 1000A clamp current transformer
4) 2000A clamp current transformer
5) Secondary pressure drop test function
6) Barcode scanner
Note: The selection of current clamps can be configured with a maximum of 4 sets per host (including 1 set as standard), and it is advisable to have a difference of 4 times the rated current between each set of current clamps!