1. Introduction
The communication of CK-T150 card reader is based on MODBUS RTU communication protocol, including the configuration of station ID, baud rate, card reading mode, etc. of the card reader, as well as the reading and writing operations of tags, all of which can be implemented through MODBUS communication instructions.
Without special configuration, the card reader defaults to MODBUS RTU slave. Therefore, as long as there is no problem with the connection, communication settings, and knowing the slave station number (or using broadcast address 0), the card reader can always be found by the MUDBUS host. When the card reader is configured to other working modes, the communication mode will act as the master, but it can still receive configuration information in MODBUS slave mode.
When the card reader is configured in non-standard MODBUS mode, it can be reconfigured using our company's matching configuration software, or the settings can be changed by sending configuration commands through MODBUS.
2. Product features
Working voltage: 10-30V;
Power consumption: 1.5W;
Working frequency: 125KHZ;
◆ Circuit protection: with polarity reversal protection;
◆ Support tag types: EMID, FDX-B;
◆ Card reading distance: 250mm (depending on the label and application environment);
◆ Card reading time: 46ms
Communication interface: RS232/RS485;
Communication protocol: Industrial MODBUS RTU communication protocol;
Working humidity: 10-90% RH;
Working temperature: -25 ℃ -+85 ℃;
Protection level: IP-65;
◆ Shell material: ABS engineering plastic.
3. Electrical parameters
Physical and environmental characteristics:
|
project |
Technical Specifications |
|
Operating temperature |
-25℃~85℃ |
|
Storage temperature |
-25℃~120℃ |
|
Humidity |
5%~95% non condensing state |
|
weight |
230g |
|
drop test |
1.2-meter free fall |
|
ESD性能 |
Air discharge ± 15KV, contact discharge ± 8KV |
|
Sealing standard |
IP67 |
Electrical parameter indicators:
|
project |
Technical Specifications |
|
Working Voltage |
10-30V |
|
power waste |
1.3W |
|
Circuit Protection |
Polarized reverse protection |
|
operating frequency |
125KHZ |
|
Support tag types |
EMID、FDX-B |
|
Reading time |
45ms |
|
card reading distance |
250mm (standard IC card) |
|
communication interface |
RS485/RS232 |
|
communication protocol |
MODBUS RTU Communication Protocol |
4. Wiring instructions
4.1 Wiring Instructions
The CK-T150 wiring port is defined as follows:
Figure 2-1 Definition of Wiring Ports
The definition of cable wiring with CK-M128P15S is as follows:
|
Corresponding pins |
color |
electrical interface |
|
1 |
red |
VCC |
|
2 |
green |
A |
|
3 |
black |
GND |
|
4 |
blue |
B |
|
5 |
brown |
DGND |
|
6 |
Huang |
TXD |
|
7 |
orange |
RXD |
|
8 |
white |
NC |
4.2 Signal indication
Red LED: Power indicator light
Green LED: Label detection and communication indicator light
The working process of the card reader: After the card reader is connected to the power supply, the red LED lights up continuously, and the card reader enters the automatic tuning state and performs self adjustment
After successful self inspection, the green LED will light up for 0.5 seconds. When the card reader detects the presence of an RFID tag, the green LED will remain on for a long time. The green LED flashes intermittently during card reader communication.
4.3 Working ProcessAfter the CK-T150 power on self-test is completed, it enters the automatic card reading mode. After scanning the tag information, the green LED indicates and stores the tag data in the corresponding register, waiting for the user to read it. This scanning method, which does not require customer intervention, is particularly suitable for logistics management, AGV station control, and other situations that require high-speed card reading.
5. Mechanical dimensions
Mechanical dimensions: 150mm * 150mm * 26mm

Electrical parameters
Physical and environmental characteristics:
project Technical Specifications Operating temperature -25℃~85℃ Storage temperature -25℃~120℃ Humidity 5%~95% non condensing state weight 230g drop test 1.2-meter free fall ESD性能 Air discharge ± 15KV, contact discharge ± 8KV Sealing standard IP67
Electrical parameter indicators:
project Technical Specifications Working Voltage 10-30V power waste 1.3W Circuit Protection Polarized reverse protection operating frequency 125KHZ Support tag types EMID、FDX-B Reading time 45ms card reading distance 250mm (standard IC card) communication interface RS485/RS232 communication protocol MODBUS RTU Communication Protocol