Microwave antenna measurement system YS1001
The antenna experimental system in the RF experimental system is mainly equipped with various microstrip antennas. In order to better complete the exp
Product details
YS1001 Microwave Antenna Measurement System
The antenna experimental system in YS1001 microwave antenna measurement system (RF antenna experimental system) is mainly equipped with various microstrip antennas. In order to better complete the experiment, not only do we need the RF transmission and reception modules provided by the RF experimental system, but we also need some supporting instruments, such as spectrometers, network analyzers, power meters, audio signal sources, etc. The picture is a physical image of a spinal antenna experiment.YS1001 Microwave Antenna Measurement System (RF Antenna Experimental System)

Antenna technology index indicators and pictures:
Whip mounted antenna Waveguide monopole antenna
Dual frequency dipole antenna Spiral antenna
Planar logarithmic periodic antenna Microstrip fractal antenna
Circularly polarized dual frequency antenna Circular antenna
Spinal antenna telescopic antenna
Yagi antenna Horn antenna
YS1001 Microwave Antenna Measurement System (RF Antenna Experimental System)dayLine experiment project:
1) Testing of antenna polarization characteristics
2) Test leading to antenna
3) Testing of antenna pattern
4) Test of antenna gain

PTZ experimental system
The pan tilt experimental system consists of a controller and a pan tilt that can rotate left and right (clockwise and counterclockwise) and up and down (as well as tilt and tilt). By setting the controller, the gimbal can be horizontally oriented at 0 °~Rotate within a range of 350 °, and pitch in the Y direction can rotate within a range of 0 °~70 ° (i.e. dynamic 140 °).This system, when combined with System 3 (and RF experimental system), can perform antenna related experiments relatively well.
3cm waveguide testing system
(Microwave Experimental Instruments in Universities)
Rich experimental project content and professional configuration
Instrument composition: (standard configuration)
1) YS1123
P≥5mw
f::8.2~12.4GHz
2) GX2B
Digital power meter
P:10μW~100mW
3) YS3892
Selective frequency amplifier
Incremental 0-60 dB square wave 1 KHz
4) TC26
Measurement line
S≤1.05
5) BD20A
Waveguide component
(13 types of components)
Experimental project:
1) Understanding and debugging of the entire system
2) Standing wave ratio measurement
3) Measurement of attenuation
4) Performance measurement of directional coupler
5) Horn antenna increment and horizontal direction demonstration(Configurable electric gimbal, controller, triangular bracket, 3D angle rotation)
6) Calibration of detection characteristics
7) frequency measurement
8) power measurement
9) Impedance measurement
10) phase measurement
11) Measurement of Magic T Characteristics
12)
13)
Tell: 85569851
PTZ controllerinstructions
1. summary
The pan tilt control system consists of a pan tilt controller, a bracket (to be selected by the user according to their needs), and a pan tilt that can rotate in both the X and Y directions. The gimbal controller adopts 1284 LCD display and uses a 4x4 matrix as a human-machine dialogue tool. In addition to the necessary interfaces for gimbal operation, the rear panel is also equipped with an RS232 interface for remote control or use with other instruments.
Attention: 1. The pan tilt cable on the back panel of the controller is designed to output 220V, please do not touch it.
To ensure accurate angle setting of the gimbal, it takes approximately 2 minutes. Please be patient when resetting.
2. technical parameter
2.1 Input voltage: 220V/50Hz
2.2 Rotation angle: horizontal * large: 350 °, vertical ± 70 °
2.3 Rotation speed: horizontal 6 °/s, vertical 3 °/s
2.4 Angle error: ± 2 °
2.5 Weight: 6kg gimbal, 4kg controller
2.6 Overall dimensions: gimbal with a diameter of 180mm × 280mm
Controller: 290mm (h) × 220mm (a) × 110mm (b)
2.7 PTZ load: 10Kg
3. Adjust the control structure
Figure 3.1 Schematic diagram of front panel structure Figure 3.2 Schematic diagram of rear panel structure
3.1 Power switch
Press the power switch to turn on the controller, and at the same time, the indicator light of the power switch will light up.
3.2 LCD display window
Display the working mode or rotation angle of the gimbal.
3. Three keyboards
The keyboard adopts a 4x4 matrix keyboard, including 10 numerical setting keys from 0-9, as well as 6 control keys for tilt, tilt, left turn, right turn, automatic rotation (horizontal direction), and start (stop). The specific operation method can be found in the panel operation instructions.
3.4 PTZ connection plug
This interface is mainly used for power supply during pan tilt operation, and its output is around 220V. Be careful when using it
3.5 RS232 interface
Through this interface, remote control of the gimbal can be achieved or used together with other instruments.
3.6 Fuse holder
Install a 3A blown fuse.
3. 7 power sockets
Input 220V, 50Hz AC power.
3.8 Grounding Pile
Used for common ground connection with other instruments.
4. Introduction to Working Mode
The gimbal can operate in automatic mode or setting mode under the control of the controller.
4.1 Automatic working mode
The automatic working mode is controlled by the controller to automatically turn left, right, tilt, tilt horizontally, and reset the pan tilt. After completing the rotation of the gimbal in the setting mode, it will automatically enter the automatic mode, and after completing the automatic rotation in the automatic mode, press any number key except 1-9 to return to the setting mode.
4.2 Setting Mode
When setting the mode, the corresponding angles in each direction are set to 0. The control of the pan tilt angle can be achieved through the combination of numerical keys and six other keys, and the pan tilt can also rotate in both horizontal and vertical directions through reasonable settings. The horizontal direction * large rotation angle can be set to 350 °, and the vertical direction * large rotation angle can be set to 140 °. In the setting mode, a single direction angle rotation can be set, or multiple directions angle rotation can be set. After setting, it can rotate in both horizontal and vertical directions simultaneously. Perform left rotation angle first and then right rotation angle in the horizontal direction, and perform pitch rotation angle first and then tilt rotation angle in the vertical direction.
4.3 Execution Mode
After setting the required rotation angle in the setting mode, press the start/stop button to enter the execution mode. After the gimbal is executed, it will automatically enter automatic mode. If the start/stop button is pressed during the execution process, it will enter the setting mode.
5. usage method
5.1 Precautions for use
a. Before using this instrument, one should first read the instrument manual and become familiar with the operating methods;
b. To ensure the long-term service life of the instrument, clean, dry, and ventilated indoor use and storage should be selected;
c. The power supply voltage should not exceed 220V ± 22V, otherwise the performance of the instrument will not be guaranteed;
d. In order to ensure the accuracy of the rotation angle setting, other operations should be performed after the gimbal reset is completed during the gimbal reset process
e. The rotation angle of the pan tilt cannot be accurately controlled in automatic working mode. It is recommended to reset or let the pan tilt rotate to the limit position after the automatic rotation is completed
5.2 Panel operation and usage section
5.2.1. Power on
Plug in the power cord, press the power switch, the power switch light will turn on, and at the same time, the gimbal will enter the automatic reset state. The automatic reset of the gimbal takes about 2 minutes. It is recommended to wait until the reset is complete before performing other operations.
5.2.2Key operation
There are a total of 17 buttons on the front panel. Including power button, 1-9 numerical keys, 0/reset, tilt, tilt, left, right, automatic/next position, start/stop. In the setting mode, press 0-9 to set the corresponding value. The power button has been introduced in 5.2.1. Below are the other 7 keys.
a. Start/Stop button
The start/stop button mainly includes three functions: start, stop, and mode switching. After setting the rotation angles in various directions in the setting mode, press this button to execute the angle setting of the gimbal in the order of first tilting and then tilting, and first left and then right. Press this button during the rotation of the pan tilt to immediately stop the rotation. In addition, this key also has a mode switching function. Pressing this key in automatic mode can switch to the setting mode; Press this key to enter automatic mode for setting mode; Press this key in execution mode to enter setup mode.
b. 0/Reset button
This key has two functions: setting the value to 0 and automatic reset function. In automatic mode, pressing this key * * times will automatically reset the gimbal, but this key will be disabled during the reset process. Press this button in automatic mode (left turn or right turn or tilt or tilt or auto) to stop the automatic rotation of the gimbal and enter the setting mode.
c. Auto/Next button
This key also has two functions: pressing this key in setting mode will automatically move the LCD cursor down one position, making it convenient to set the rotation angle in various directions; In automatic mode, pressing this button * * times will automatically rotate the pan tilt in the horizontal direction until a stop command is issued. Press this button in automatic mode (left or right turn, tilt or pitch) to stop the gimbal from automatically rotating and enter the setting mode.
d. Bending key
This key also has two functions: in the setting mode, pressing this key will automatically move the cursor to the first position of the tilt direction angle, making it easier to set the tilt direction angle; In automatic mode, if this button is pressed * * times, the pan tilt will automatically tilt until a stop command is issued or it reaches the limit position. Press this button in automatic mode (left turn or right turn or tilt or auto) to stop the gimbal from automatically rotating and enter the setting mode.
e. Upward key
This key also has two functions: in the setting mode, pressing this key will automatically move the cursor to the first position of the tilt direction angle, making it easier to set the tilt direction angle; In automatic mode, if this button is pressed * * times, the pan tilt will automatically tilt until a stop command is issued or it reaches the limit position. Press this button in automatic mode (left turn or right turn or tilt or auto) to stop the gimbal from automatically rotating and enter the setting mode.
f. Left click
This key also has two functions: in the setting mode, pressing this key will automatically move the cursor to the first position of the left turn direction angle, making it easier to set the left turn direction angle; In automatic mode, if this button is pressed * * times, the gimbal will automatically turn left until a stop command is issued or the limit position is reached. Press this button in automatic mode (tilt or right turn or tilt or auto) to stop the gimbal from automatically rotating and enter the setting mode.
g. Right click
This key also has two functions: in the setting mode, pressing this key will automatically move the cursor to the first position of the right turn direction angle, making it easier to set the right turn direction angle; In automatic mode, if this button is pressed * * times, the gimbal will automatically turn right until a stop command is issued or the limit position is reached. Press this button in automatic mode (left turn or tilt or tilt or auto) to stop the gimbal from automatically rotating and enter the setting mode.


Related products:YS-2499ABSeries dual channel pulse waveform displayPeak microwave power meter (dual channel pulse high-power meter);GX2BB03 series microwave power meter (RF power meter); YS1125 (B) microwave signal source (RF signal generator); YS3892 frequency selective amplifier; PXSeries microwave frequency meter (RF frequency meter);3cm10cm)Waveguide testing system;FYS3000Complete waveguide testing systemAnd accessories; ASA6030 Microwave (Antenna) Testing System (Antenna Measurement Training System)TC26Three centimeter waveguide measurement line;RCQ1AMicrowave leakage energy tester;SHK-4(3)Variable RF attenuator;BSeries fixed RF attenuator;YTJ8-3YTJ8-4YTJ8-5 seriesSMAJoint coaxial crystal RF detector; TJ8-4, TJ8-3, TJ8-5, TJ8-2 series coaxial crystal RF detectors, with optional British (N-type) or metric (L16) connector types; TTK-2/4Series RF coaxial switch;FYDTT)Series RF directional coupler;YSDTZ)Series microwave load;FYS(BD)Series waveguide components, etc