Product details

The fully disinfected pipette can disinfect the entire tube under high temperature and pressure conditions of 121 ℃ and 1atm for 20 minutes, without the need for special preparation. After disinfection, it must be left for more than 12 hours to fully cool and dry.

It is recommended to check the performance of the pipette after each round of high-temperature and high-pressure disinfection. It is also recommended to reapply lubricant to the piston and sealing ring of the pipette after every 10 rounds of high-temperature and high-pressure disinfection.

Each pipette has undergone factory testing and calibration in accordance with the requirements of ISO8655 before leaving the factory, and the claimed inaccuracy and precision are superior to the specified standards of ISO8655. During the use of pipettes, deviations may occur due to various reasons, and regular calibration is an important means to ensure their accuracy.

Characteristics of single channel pipette

·Lightweight and designed to conform to ergonomics

·Digital window, making the set range clear at a glance

·Wide range of measurement, from 0.1 μ l to 10ml

·Using attachment tools allows for convenient and efficient calibration and maintenance

·Accurate liquid separation, each pipette is calibrated according to EN/ISO8655 standards

·The entire unit can withstand high temperature and high pressure disinfection

·Adopting new materials and high-temperature and high-pressure resistant structures

The multi-channel pipette also has the following innovative features

·The nozzle ejector can simultaneously eject multiple suction nozzles, which is efficient and labor-saving

·8 and 12 pipettes of various ranges are suitable for standard 96 well plates

·The liquid head can rotate 360 degrees, making it convenient for pipetting

·Each nozzle connection has an independent piston device, making maintenance and repair convenient

·Special nozzle connector design, easy to observe the sealing condition of the suction nozzle

technical parameter

MicroPette plusSingle channel manually adjustable pipette

range

increment

Measurement volume (μ l)

Maximum allowable system error

(Inaccuracy)

Maximum allowable random error

(Inaccurate)

%

μl

%

μl

0.1-2.5μl

0.05μl

2.5

2.50%

0.0625

2%

0.05



1.25

3%

0.0375

3%

0.0375



0.25

12%

0.03

6%

0.015

0.5-10μl

0.1μl

10

1%

0.1

0.80%

0.08



5

1.50%

0.075

1.50%

0.075



1

2.50%

0.025

1.50%

0.015

2-20μl

0.5μl

20

0.90%

0.18

0.40%

0.08



10

1.20%

0.12

1%

0.1



2

3%

0.06

2%

0.04

5-50μl

0.5μl

50

0.60%

0.3

0.30%

0.15



25

0.90%

0.225

0.60%

0.15



5

2%

0.1

2%

0.1

10-100μl

1μl

100

0.80%

0.8

0.15%

0.15



50

1%

0.5

0.40%

0.2



10

3%

0.3

1.50%

0.15

20-200μl

1μl

200

0.60%

1.2

0.15%

0.3



100

0.80%

0.8

0.30%

0.3



20

3%

0.6

1%

0.2

50-200μl

1μl

200

0.60%

1.2

0.15%

0.3



100

0.80%

0.8

0.30%

0.3



50

1%

0.5

0.40%

0.2

100-1000μl

5μl

1000

0.60%

6

0.20%

2



500

0.70%

3.5

0.25%

1.25



100

2%

2

0.70%

0.7

200-1000μl

5μl

1000

0.60%

6

0.20%

2



500

0.70%

3.5

0.25%

1.25



200

0.90%

1.8

0.30%

0.6

1000-5000μl

50μl

5000

0.50%

25

0.15%

7.5



2500

0.60%

15

0.30%

7.5



1000

0.70%

7

0.30%

3

2-10ml

0.1ml

10ml

0.60%

60

0.20%

20



5ml

1.20%

60

0.30%

15



2ml

3%

60

0.60%

12

8Dao manual adjustable pipette

range

increment

Measurement volume (μ l)

Maximum allowable system error

(Inaccuracy)

Maximum allowable random error

(Inaccurate)

%

μl

%

μl

0.5-10μl

0.1μl

10

1.50%

0.15

1.50%

0.15



5

2.50%

0.125

2.50%

0.125



1

4%

0.04

4%

0.04

5-50μl

0.5μl

50

1%

0.5

0.50%

0.25



25

1.50%

0.375

1%

0.25



5

3%

0.15

2%

0.1

50-300μl

5μl

300

0.70%

2.1

0.25%

0.75



150

1%

1.5

0.50%

0.75



50

1.50%

0.75

0.80%

0.4

12Dao manual adjustable pipette

range

increment

Measurement volume (μ l)

Maximum allowable system error

(Inaccuracy)

Maximum allowable random error

(Inaccurate)

%

μl

%

μl

0.5-10μl

0.1μl

10

1.50%

0.15

1.50%

0.15



5

2.50%

0.125

2.50%

0.125



1

4%

0.04

4%

0.04

5-50μl

0.5μl

50

1%

0.5

0.50%

0.25



25

1.50%

0.375

1%

0.25



5

3%

0.15

2%

0.1

50-300μl

5μl

300

0.70%

2.1

0.25%

0.75



150

1%

1.5

0.50%

0.75



50

1.50%

0.75

0.80%

0.4

Manually fix the pipette

range

increment

Measurement volume (μ l)

Maximum allowable system error

(Inaccuracy)

Maximum allowable random error

(Inaccurate)

%

μl

%

μl

5μl

-

5μl

1.30%

0.065

1.20%

0.06

10μl

-

10μl

0.80%

0.08

0.80%

0.08

20μl

-

20μl

0.60%

0.12

0.50%

0.1

25μl

-

25μl

0.50%

0.125

0.30%

0.075

50μl

-

50μl

0.50%

0.25

0.30%

0.15

100μl

-

100μl

0.50%

0.5

0.30%

0.3

200μl

-

200μl

0.40%

0.8

0.20%

0.4

250μl

--

250μl

0.40%

1

0.20%

0.5

500μl

-

500μl

0.30%

1.5

0.20%

1

1000μl

-

1000μl

0.30%

3

0.20%

2

2000μl

-

2000μl

0.30%

6

0.15%

3

5000μl

-

5000μl

0.30%

15

0.15%

7.5