Beiying Electronic Technology (Shanghai) Co., Ltd
Home>Products>Micro differential pressure gauge and wind pressure gauge TSI 5815/5825
Micro differential pressure gauge and wind pressure gauge TSI 5815/5825
TSI Micro Differential Pressure Gauge Wind Pressure Gauge TSI 5815/5825 Model: TSI 5815/5825 DP-CALC 5815 and 5825 Micro Differential Pressure Gauge m
Product details

TSI Micro Differential Pressure Gauge Wind Pressure Gauge TSI 5815/5825 from the United States

model:TSI 5815/5825


DP-CALC 5815 and 5825 micro differential pressure gauges make pressure testing in HVAC easier for you. These sturdy and durable instruments can be used to measure wind speed inside ducts using pitot tubes. The DP-CALC 5815 handheld digital micro differential pressure gauge is easy to operate and can quickly and accurately measure differential pressure and static pressure. The high-performance DP-CALC 5825 can also calculate air volume and has automatic data recording function.


倍迎电子


Features and advantages (5815)/5825):
Multiple pressure gauges can be used to measure wind speed using a Pitot tubePosition: H2O/Pa/hPa/kPa/mmHg


Type 5825Additional features:
Calculate air volume;
Can store up to 12700 data and100 data sets including a set of LogDat2 data download software.



5815

5825



pressure

Scope 1

-28.0~+28.0 mm Hg,- 3735~+3735Pa

error

± 0.01 mmHg, ± 1% ± 1Pa of reading

resolution

0.1Pa,0.001 mm Hg

Wind speed (pitot tube)

Scope 2

1.27~78.7m/s

Accuracy 3

At 10.16m/s, ± 1.5%

resolution

0.1 m/s

Instrument temperature requirements

operate temperature

5~45℃

storage temperature

-20~60℃

Volume flow rate

Duct size

/

2.5-1270cm, increments of 0.1cm

range


The actual flow rate is the wind speed and the actual duct area or pressure differenceThe function of K coefficient

Data storage capability

capacity

/

12700 data points and 100 data sets

Collection interval

1s~1h

Instrument dimensions

8.4 cm × 17.8 cm × 4.4 cm

Instrument weight (with battery)

0.27kg

power supply

Four AA batteries or optional AC adapter


1Range upper limit=7 psi190 in. H2O, 360mmHg, 48kPa

2The method of measuring wind speed using pressure is not recommended5m/sUsed under wind speed

3Accuracy is a function of the conversion rate from pressure to wind speed. When the actual pressure value increases, the accuracy increases.