Medical purified water equipment
Medical purified water equipment
Product details

Medical purified water equipment


Pharmaceutical purified water indicators
1. Chemical indicators: must comply with the requirements of the 2010 edition of the Pharmacopoeia of the People's Republic of China for pharmaceutical purified water
2. Hygiene examination: Microbial 10CFU/100ml
3. endotoxin 0.25EU/ml
4. Conductivity ≤ 2 μ S/cm (resistivity ≥ 0.5 M Ω* CM)
Technical characteristics of equipment
1. The system adopts fully automatic control (manual control can also be used), and automatic backwashing and regeneration programs can be set during system operation;
2. The first and second level reverse osmosis systems are equipped with reflux pipelines, and the reverse osmosis equipment is equipped with chemical cleaning and disinfection devices;
3. A pH adjustment device is installed between the primary and secondary reverse osmosis to ensure that the conductivity of the equipment's produced water meets the requirements of the pharmacopoeia;
4. The secondary reverse osmosis membrane adopts a positively charged anti pollution reverse osmosis membrane to ensure the long-term stable operation of the reverse osmosis equipment;
5. The first stage reverse osmosis pipeline adopts 304 stainless steel material, and the second stage reverse osmosis adopts 316L stainless steel material;
6. Online conductivity detection instruments are installed in both the first and second stage reverse osmosis equipment, and the conductivity of the produced water can be observed at any time;
7. A low-voltage protection switch is installed before the first level reverse osmosis, and low-voltage and high-voltage protection switches are installed before the second level reverse osmosis;
8. The first and second level reverse osmosis water recovery rates can be adjusted, with a first level reverse osmosis recovery rate of 60% -65% and a second level reverse osmosis recovery rate of 70%;
9. All pre-treatment devices are made of original imported parts; UPVC pipes are used for the piping between pre-processing equipment.
10. The purified water storage tank is equipped with a breathing filter, and the conveying pipeline is equipped with ultraviolet sterilizers and microporous filters to ensure that the pure water meets hygiene requirements.
technological process
1. Raw water tank → raw water booster pump → multi-media filter → activated carbon filter → water softener → security filter → first stage reverse osmosis → pH adjustment → intermediate water tank → second stage reverse osmosis → purified water tank → sterilization system → purified water delivery pump → ultraviolet sterilizer → microporous filter → water point
2. Raw water tank → raw water booster pump → multi-media filter → activated carbon filter → water softener → security filter → first stage reverse osmosis → pH adjustment → intermediate water tank → second stage reverse osmosis → pure water tank → intermediate water pump → EDI system → purified water tank → sterilization system → purified water delivery pump → ultraviolet sterilizer → microporous filter → water point
3. Raw water tank → Raw water booster pump → Multi medium filter → Activated carbon filter → Softener → Security filter → Primary reverse osmosis machine → Intermediate water tank → Intermediate water pump → EDI system → Purified water tank → Sterilization system → Purified water delivery pump → UV sterilizer → Microporous filter → Water point
Equipment Overview
(1) The structural design should be simple, reliable, and easy to disassemble.
(2) For the convenience of disassembly, replacement, and cleaning of parts, the design of the actuator should use standardized, universal, and systematic components as much as possible.
(3) The inner and outer wall surfaces of the equipment,
(4) The preparation of purified water equipment should use low-carbon stainless steel or other materials that have been verified to not pollute water quality. The equipment for preparing purified water should be regularly cleaned and the cleaning effect should be verified.
(5) The material in contact with injection water must be high-quality low-carbon stainless steel or other materials that have been verified not to pollute the water quality. The equipment for preparing injection water should be regularly cleaned and the cleaning effect should be verified.
(6) The storage period of purified water should not exceed 24 hours,
(7) Transportation of pharmaceutical water
Relevant requirements of GMP
1. The structural design should be simple, reliable, and easy to disassemble.
2. For the convenience of disassembly, replacement, and cleaning of parts, the design of the actuator should use standardized, universal, and systematic components as much as possible.
3. The inner and outer wall surfaces of the equipment should be smooth, flat, without dead corners, and easy to clean and sterilize. The surface of the parts should be treated with chrome plating or other surface treatments to resist corrosion and prevent rusting. Avoid using paint on the outside of the equipment to prevent peeling.
4. The preparation of purified water equipment should use low-carbon stainless steel or other materials that have been verified to not pollute water quality. The equipment for preparing purified water should be regularly cleaned and the cleaning effect should be verified.
5. The material in contact with injection water must be high-quality low-carbon stainless steel or other materials that have been verified not to pollute the water quality. The equipment for preparing injection water should be regularly cleaned and the cleaning effect should be verified.
6. The storage period of purified water should not exceed 24 hours, and its storage tank should be made of stainless steel material or other materials that have been verified to be non-toxic, corrosion-resistant, and do not leak out pollutant ions. A hydrophobic sterilization filter with non shedding fibers should be installed to protect its ventilation port. The inner wall of the storage tank should be smooth, and there should be no dead corners or sand holes in the connecting pipes and welds. Sensors that do not cause stagnant water pollution and display parameters such as liquid level, temperature, and pressure should be used. Regularly clean, disinfect and sterilize storage tanks, and verify the effectiveness of cleaning and sterilization.
7. Transportation of pharmaceutical water
1) Purified water and pharmaceutical water should be transported using stainless steel pumps that are easy to disassemble, clean, and disinfect. In situations where purified water and injection water require compressed air or nitrogen pressure delivery, the compressed air and nitrogen must be purified.
2) Purified water should be transported through a circulating pipeline. The pipeline design should be concise and avoid blind pipes and dead corners. The pipeline should be made of stainless steel pipes or other pipes that have been verified to be non-toxic, corrosion-resistant, and do not leak pollutants. Valves should be sanitary grade valves without dead corners, and the flow direction of purified water should be indicated.
3) The pipelines and pumps used for transporting purified water and injection water should be regularly cleaned, disinfected, and sterilized before being put into use.
8. The design of pressure vessels must be undertaken by licensed units and qualified personnel, and must be handled in accordance with the relevant provisions of the national standards of the People's Republic of China, "Steel Pressure Vessels" (GB150-80) and "Safety Technical Supervision Regulations for Pressure Vessels".