Medical fire electrical safety system

When the human body accidentally touches a wire at the output end of the device with one hand, the current passing through the human body is lower than the specified safe current10mA, People can get rid of the power supply in a timely manner without causing casualties.
When the insulation of the power supply lines for equipment control and load equipment is damaged and there is a metallic grounding short circuit in the lines, it can effectively suppress arc sparks and avoid the occurrence of such electrical fire accidents. And it can continue to operate without electricity, ensuring production safety.
When any power line of the output line of this device is damaged in insulation and forms a ground short circuit, it will not cause leakage or power outage to the grid, ensuring continuous, safe, and reliable power supply to the grid.
Better material technology can effectively filter out power grid harmonics and prevent damage to the output load caused by harmonics. At the same time, it also prevents the interference of harmonics generated by loads on the power grid and prevents damage to power grid equipment.
When the output line or load of the device experiences insulation damage and a short circuit with the ground wire, the device can detect the insulation resistance value in real time and give an alarm prompt to ensure continuous power supply.
This device has overvoltage, undervoltage, overcurrent, overload, and over temperature protection functions. When the measured values of the above parameters exceed the set values, the device will prompt corresponding alarm information.
Technical ParameterASCO~01
1. Rated capacity: 100VA-15KVA;
2. Input/output voltage: 400v, 380v, 220v;
3. Control the current that the human body can withstand electric shock to be less than 5mA
4. Metallic grounding: discharge current less than 30mA;
5. The resistance at both ends of the impedance tester's input and output lines is less than 2 Ω;
6. Power frequency withstand voltage between the shell and the main circuit: not less than 1.5KV/1min;
7. Insulation resistance between the shell and the main circuit: not less than 1.5M Ω;
8. Altitude less than 4000m (downgraded for use above 4000m);
9. Operating environment temperature -20 ℃~60 ℃, environmental humidity less than 90%;
10. Electrical strength: 3000VAC/1min;
11. Weight: The actual weight of the product shall prevail.
Technical ParameterASCO~02
1. Rated capacity: 100VA-500KVA;
2. Input/output voltage: 400v, 380v, 220v;
3. Control the current that the human body can withstand electric shock to be less than 5mA
4. Metallic grounding: discharge current less than 30mA;
5. The resistance at both ends of the impedance tester's input and output lines is less than 2 Ω;
6. Power frequency withstand voltage between the shell and the main circuit: not less than 1.5KV/1min;
7. Insulation resistance between the shell and the main circuit: not less than 1.5M Ω;
8. Altitude less than 4000m (downgraded for use above 4000m);
9. Operating environment temperature -20 ℃~60 ℃, environmental humidity less than 90%;
10. Electrical strength: 3000VAC/1min;
11. Weight: The actual weight of the product shall prevail.
Technical ParameterASCO~03
1. 1 residual current+5 temperature channels+3 voltage channels+3 current channels;
2. Rated voltage: AC 220V (50Hz);
3. Display mode: color screen display+status icon;
4. Alarm method: sound and light alarm;
5. Linkage control: switch output;
6. Network standard: NB IoT;
7. External communication: RS485;
8. Temperature environment: -20 ℃ to 65 ℃;
9. Relative humidity: 95% RH (no condensation at 40 ℃);
10. Installation method: 35mm standard guide rail installation;
11. 24/7 online and wireless transmission of physical data for monitoring residual current, current, and temperature (wire temperature and ambient temperature).
Technical ParameterASCO~04
1. Withstand voltage 4KV
2. Power supply voltage AC50-60HZ/220V;
3. The monitored system is AC50-400HZ/230V;
4. Insulation resistance measurement range: 0~5000KQ;
5. The response value can be adjusted from 50-500KQ
6. Measurement time<3s, measurement voltage 12V, measurement current<50uA;
7. Internal resistance>240KQ, impedance>200KQ;
8. The measurement range is 1-50A, and the response value can be adjusted from 5A to 50A;
9. Environmental working temperature: 0 ° C~45 ° C
10. Temperature alarm activation response 4KQ, release alarm response 1.6KQ;
11. Serial interface RS485 protocol, communication distance<1200m, rail mounted installation.
In addition to the full range of circuit protection functions, intelligent circuit breakers also have real-time monitoring, data acquisition, remote self inspection, and warning mechanisms.