Shanghai Shouli Industrial Co., Ltd
Home>Products>MX6 iBrid Multi Gas Monitor
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    18930767719
  • Address
    Room 307, Huacheng Plaza, 1471 Gumei Road, Minhang District, Shanghai
Contact Now
MX6 iBrid Multi Gas Monitor
1-6 gas detectors, color LCD display, 25 types of sensors to choose from, including PID and infrared sensors. Optional installation of sensors: Cl2 (c
Product details

Product Introduction

summary:

  • Can simultaneously detect 1 to 6 gases (any choice)
  • Diffusion and pumping methods
  • Computer menu based operation orientation, convenient for users to use
  • 25 sensors to choose from (including electrochemical, catalytic combustion, infrared, PID)
  • Up to six electrochemical toxic gas sensors can be installed simultaneously
  • Can install both infrared and PID sensors simultaneously
  • Can install two infrared sensors (LEL/CO) simultaneously2
  • Full color display screen, capable of displaying measurement results in numerical and graphical formats
  • High decibel and high brightness sound and light alarm
  • Large data storage and download function

MX6 iBridTMNot only is it an intelligent product of Industrial Scientific's latest monitoring technology, but it is also the world's * composite gas monitoring instrument with a color LCD display and multiple sensors for arbitrary selection.

The large screen color display allows the instrument to read clearly in any brightness environment, such as low light, high light, etc., enhancing safety. Potential gas hazards can be more easily detected in outdoor, indoor, or underground work environments.

MX6 iBridTMDiffusion and integrated pumping operations can be used, which greatly facilitates personal protection and remote measurement of confined space entry.

MX6 iBridTMIt is currently the most convenient instrument in the world to install various sensors, whether it is electrochemical, catalytic combustion, infrared or PID sensors, they can be installed on the instrument at the same time, providing the most effective choice for users in various industries. in addition to, MX6 iBridTMThe intuitive computer operation menu and five directional navigation keys enable users to conveniently and intuitively set up and select functions for the instrument. Support online charts to display real-time readings and record data. MX6 iBridTMThe data recording and downloading function with large storage capacity provides users with comprehensive data browsing and processing functions.

MX6 iBridTMThe shell is sturdy and comes with a lifetime warranty for DS2 units and iNetTMThe instrument network is fully compatible.

Technical parameters:

Shell material: Lexan resin/ABS/stainless steel with protective rubber filling
Size: 135 mm x 77 mm x 43 mm - diffusion version
Weight: Generally 409 g
Sensor principle: Combustible gas/methane - catalytic combustion/infrared
Oxygen and Toxic Gases - Electrochemistry
CO2- Infrared
Volatile Organic Compounds (VOCs) -10.6 eV Photoionization Detector (PID)
Range:
Gas
chemical formula
measuring range
accuracy
combustible gas LEL (Catalytic Combustion) 0 to 100% LEL 1% or 10 ppm
Combustible gas (optional) LEL (infrared) 0 to 100% LEL 1%
methane CH4(Catalytic combustion) 0 to 5% VOL 0.1%
Methane (optional) CH4(Infrared) 0 to 100% VOL 1%
oxygen O2 0 to 30% of VOL 0.1%
carbon monoxide CO 0 to 1000 ppm 1 ppm
Carbon monoxide (optional) CO 0 to 9999 ppm 1 ppm
hydrogen sulfide H2S 0 to 500 ppm 0.1 ppm
Carbon monoxide/hydrogen sulfide** CO/H2S (COSH) (CO) 0 to 500 ppm
(H2S) 0 to 200 ppm
(CO) 1 ppm
(H2S) 0.1 ppm
hydrogen H2 0 to 1000 ppm 1 ppm
Nitrogen oxide NO 0 to 1000 ppm 1 ppm
chlorine Cl2 0 to 100 ppm 0.1 ppm
Nitrogen dioxide NO2 0 to 100 ppm 0.1 ppm
sulfur dioxide SO2 0 to 100 ppm 0.1 ppm
Hydrogen cyanide HCN 0 to 30 ppm 0.1 ppm
Hydrogen chloride HCl 0 to 30 ppm 0.1 ppm
ammonia NH3 0 to 100 ppm 1 ppm
chlorine dioxide ClO2 0 to 1 ppm 0.01 ppm
phosphine PH3 0 to 5 ppm 0.01 ppm
Phosphine (optional) PH3 0 to 1000 ppm 1 ppm
carbon dioxide CO2 0 to 5% VOL 0.01%
Volatile organic compounds (general) PID 0 to 2000 ppm 0.1
**2-in-1 sensor
Display screen/reading: STN color graphic LCD
Working temperature range: Normally:- 20 º C to 55 º C
Working humidity range: Generally 15% to 95%, non condensing (continuous)
Power supply/running time: Rechargeable lithium-ion (Li ion) battery pack (usually 24 hours)
Rechargeable enhanced lithium-ion (Li ion) battery pack (with a regular working time of 36 hours)
Replaceable AA alkaline battery pack (with a regular working time of 10.5 hours)
authentication: IECEx/ATEX: Intrinsic safety: EEx ia d IIC T4
Equipment group and classification: II 2G
UL Laboratory (UL): Class I, Groups A, B, C, D T4; AEx ia d IIC T4
Canadian Standards Institute: Level I, Groups A, B, C, D T4
Coal Mine Safety and Health Administration (MSHA): CFR30, Parts 18 and 22, can be safely applied to methane/air mixtures

performance
advantage
Color graphic LCD display
Use color graphics to present data clearly to users.
Menu driven PEG (portable built-in graphical user interface) operating system
Implement navigation operations through instrument performance (easy to understand graphical user interface, i.e. GUI).
25 interchangeable/field replaceable sensors, including PID, infrared (IR, catalytic particle, and electrochemical sensing functions)
Provide flexible monitoring for various applications. Reduce operating costs and downtime related to instrument/sensor services.
iNet ™ We can provide services for you at any time
Each instrument is shipped in iNet ready state, allowing users to easily connect devices and their supporting equipment, achieve iNet services, and run monitoring programs.
Multilingual operation
You can choose one of the pre programmed language configurations to provide convenience and flexibility for multilingual and global staff.
Five channel instrument navigation button
The single key fusion of up, down, left, right, and confirm functions provides clear and recognizable tactile feedback for users to use the instrument's graphical menu options.
Diffusion or integration sampling operation.
A set of equipment can achieve continuous monitoring in diffusion applications or be used in conjunction with an integrated sampling pump for sampling operations (such as entering confined spaces).
In terms of power supply, lithium-ion batteries and alkaline batteries can be used alternately.
Various power sources (including battery charging technology) provide users with 24/7 monitoring performance, and the use of battery power only requires short-term advance notice.
Incremental range lithium-ion battery pack
When using a sampling pump and PID or infrared sensor, continuous operation time of 36 hours can be achieved, and the operation time can be extended in high-power applications.
Numerical, graphical, and textual display modes
The instrument display screen can be personalized to provide gas concentration readings, continuous graphical display of hazardous trends, or only display "continue/do not continue" for user understanding.
Extended data recording memory
The onboard memory provides reading storage for 6 gases at 1-minute intervals and can run for at least 1 year.
Onboard event recorder
You can view the latest 15 gas alarm events on the instrument display screen, providing historical feedback information required for event review and evaluation.
The operating system can be configured by the user themselves
Users can adjust the instrument for specific display, alarm, calibration, data recording, and other instrument operations as needed.
After startup, it can perform impact testing and self-test functions
Users can choose to configure the instrument to perform self-test or impact testing programs during instrument startup - ensuring that the instrument has been properly tested before use.
Working with DS2 Docking Station ™ compatible
Provide automatic calibration and record maintenance to reduce the total cost of instrument operation and ensure accurate archiving. Simplify training procedures, reduce the time and calibration gas required for each calibration operation.
Fill composite material/stainless steel structure
The sturdy construction provides excellent durability required for operation in harsh industrial environments
And immersion protection function.
Enhanced radio frequency interference (RFI) protection function through electronic means.
Enhanced design can protect workers and operation processes from the influence of RF interference sources, eliminate false alarms and instrument failures

Sensor:

Part number explain
17124975-1 Carbon monoxide (CO)
17124975-2 Hydrogen sulfide (H)2S)
17124975-3 Oxygen (O)2
17124975-4 Nitrogen dioxide (NO)2
17124975-5 Sulfur dioxide (SO)2
17124975-6 Ammonia (NH)3
17124975-7 Chlorine (Cl2
17124975-8 Chlorine dioxide (ClO)2
17124975-9 Phosphine (PH)3)(Low 0-5 ppm)
17124975-A Hydrogen chloride (HCl)
17124975-B Hydrogen cyanide (HCN)
17124975-C Hydrogen (H)2
17124975-D Nitrogen oxide (NO)
17124975-E Phosphine (PH)3)(High 0-1000 ppm)
17124975-G Carbon monoxide (anti H)2Interference (CO/anti H)2Interference)
17124975-H High carbon monoxide (CO)
17124975-J Carbon monoxide/hydrogen sulfide (CO/H)2S)
17124975-K LEL (Pentane)
17124975-L %LEL/Methane (CH)4
17124975-M Methane (CH)4) (0-5%)
17124975-N Methane (CH)4) (IR)
17124975-P Hydrocarbons (HC) (IR)
17124975-Q Carbon dioxide (CO)2) (IR)
17124975-R Photoionization organic compound gas detector (PID)

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!