MESP-405 power system specific oil chromatography analyzer
Can achieve the analysis of nine components of dissolved gases (H2, 02, N2, CH4, C2H2, C2H4, C2H6, CO, CO2) in oil at once Cheng Sheng heating rate: 0
Product details

Special oil chromatography analyzer for power system

application
The specialized oil chromatography analyzer for power systems uses gas as the mobile phase (carrier gas). When the sample is "injected" into the injector by a microinjector, it is carried by the carrier gas into the packed column or capillary chromatograph.
Due to the difference in distribution or adsorption coefficients between the mobile phase (gas phase) and the stationary phase (liquid or solid phase) of each component in the sample in the chromatograph, under the flushing of the carrier gas, each component
Repeatedly allocate between two phases to separate each tissue in the column and each component in the column, and then use a detector attached to the column to determine the physical properties of each component
Learn the characteristics and detect each component in order. The MESP-405 power system specific oil chromatography analyzer is an analytical instrument manufactured based on the above principle.

Main structure of specialized oil chromatography analyzer for power system
The specialized oil chromatography analyzer for power systems consists of flow control components, sampler, chromatographic column box, detector, temperature control and detector circuit components, chromatographic workstation, and other parts.
The middle part of the basic instrument is the chromatography column box, the upper right part is the microcomputer temperature controller, the lower right part is the FID microcurrent amplifier, and the left part of the instrument is the flow control component and gas path panel
The upper right part of the box is the installation position for the ionization detector (two flame ionization detectors are installed for the base type) and the thermal conductivity cell detector (TCD), while the upper left part of the column box is the double
Fill column sampler or capillary sampler.
The specialized oil chromatography analyzer for power systems is designed in accordance with the requirements of the Ministry of Energy standard SD-304-89 "Determination of Dissolved Gas Components in Insulation Oil (Chromatography Method)", widely absorbing the advantages of similar instruments at home and abroad
Microcomputer controlled, stable performance, professional chromatograph for power systems. The instrument adopts a dual column parallel shunt system. The basic type includes TCD and FID detectors and methane converters, which can be implemented in one go
Analysis of nine components of dissolved gases in oil (H2, 02, N2, CH4, C2H2, C2H4, C2H6, CO, CO2)