M7-29 type coal powder centrifugal fan usage:
The M7-29 coal powder centrifugal fan is designed to meet the performance requirements of the coal powder combustion system in thermal power plant boilers, and is used to blow coal powder into the boiler. The coal powder cannot directly pass through the impeller, otherwise the impeller is prone to wear. The snail shell is lined with a protective plate for replacement after wear and tear. The bearing box contains lubricating oil for bearing heat dissipation and is equipped with cooling water pipes to cool the lubricating oil.
M7-29 type coal powder centrifugal fan type:
The M7-29 coal powder centrifugal fan is a single suction type, consisting of six models: M7-29 No.11, 12.5, 13, 14.5, 16, and 17.
2. The M7-29 coal powder centrifugal fan is made into two types: clockwise rotation and counterclockwise rotation. When viewed from one end of the motor and the impeller rotates clockwise, it is called a clockwise rotating fan, represented by "clockwise"; The counterclockwise rotation of the impeller is called a counterclockwise rotating fan, represented by "counterclockwise".
3. The outlet position of the fan is represented by the angle of the air outlet of the casing, with a total of 16 specifications ranging from 0 ° to 225 °.
Debugging and maintenance of M7-29 coal powder centrifugal fan
1. The fan must be installed according to the prescribed procedures and tested before it can be officially put into production.
If any abnormal situation is found during the operation of the fan, it should be stopped immediately to identify the cause and eliminate the fault before continuing to operate.
3. The fan should be regularly inspected according to its usage.
4. The operating speed of the fan shall not exceed the maximum allowable operating speed, and the use of pulley variable speed is not allowed.
5. The bearing box of the fan adopts water cooling, and the water pressure should not exceed 0.4Mpa. Due to different temperatures and seasonal changes in various regions, the water flow rate can also be the same. Generally, the water flow rate can be considered as 0.5-1m ³/h. At the same time, attention should be paid to the water quality to avoid scaling and blockage in the channel, which will affect the cooling effect.
If the impeller of the fan is worn out, it should be re balanced and corrected after welding repair.
The bearing temperature of the fan is generally not higher than 40 ℃ above the ambient temperature.
8. The bearings should be lubricated with thin oil, and it is recommended to use N32 mechanical oil.
9. The effective value (root mean square) of the vibration velocity of the bearing box during normal operation is ≤ 6.3 mm/s.

Parameters of M7-29 coal powder centrifugal fan

PRODUCT MODEL

rotational speedr/min

ordername

Total pressurePa

internet trafficm³/ h

motor

typename

workratekW

M7-29№ 11 D

1450

1

5099~5217

11500~14350

Y225S-4 (380V)

37

2

5246~5178

17200~20100

Y250M-4 (380V)

55

3

5099~4687

23000~28750

Y280S-4 (380V)

75

M7-29№12.5D

1450

1

6600~6747

16850~21100

Y280S-4 (380V)

75

2

6796~6693

25300~29500

Y280M-4 (380V)

90

3

6609~6433

33500~38000

Y315S-4 (380V)

110

4

6061

42200

Y315M-4 (380V)

132

M7-29№ 13 D

1450

1

7414~7571

20000~25000

Y280M-4 (380V)

90

2

7610

30000

Y315S-4 (380V)

110

3

7512~7414

35000~40000

Y315M-4 (380V)

132

4

7217

45000

Y315L1-4 (380V)

160

5

6796

50000

JS117-4 (380V)

180

M7-29№14.5D

1450

1

8894

26300

Y315M-4 (380V)

132

2

9091~9140

32900~39490

Y315L1-4 (380V)

160

3

9022

46100

Y315L2-4 (380V)

200

4

8894~8649

52650~59200

Y355M2-4 (380V)

250

5

8159

65900

JS127-4 (380V)

260

M7-29№ 16 D

1450

1

10346~10415

28500~36800

JS117-4 (380V)

180

2

10571~10493

45500~54400

Y355M2-4 (380V)

250

3

10277~9905

61400~69200

Y355L2-4 (380V)

315

4

9610

77000

Y400-4 (6000V)

355

M7-29№ 17 D

1450

1

11670~12013

34300~53800

Y355L1-4 (380V)

280

2

12013

63300

Y400-4 (6000V)

355

3

11768~11425

72800~82300

JS148-4 (6000V)

440

4

11032

91800

JS1410-4 (6000V)

500



Attention: Please confirm and indicate the fan number, air volume, speed, pressure, outlet angle, rotation direction, and motor model specifications when placing an order. If there are special requirements, please specify them.