Test project:Test project
There are multiple models in this series, each with different functions. Please refer to the detailed parameter information table for details
1. Loose fitting(Natural accumulation)densitybulk density
2. Compacted densitytap density
3. Angle of reposeAngel of repose
4. Mass flow ratemass flow velocity
5. Volume flow ratevolume flow rate
6.Liquidity index (Karl index and Hausner index)Flow index
List of Configuration for Measuring the Angle of Rest of Granules in Granules
Reference standard:standard
1. ISO902-1976; ISO4324; GB6521-86 ; ISO4490-1978;
2. GB1482-84; ISO903-1976; GB6522-86 ; GB11986;
3. DIN ISO 4324 – December 1983; USP (United States Pharmacopeia);
4. BP (British Pharmacopoeia); EP (European Pharmacopoeia) specification requirements
5. U.S.AATSM6393-08;European Pharmacopoeia07/2010:20934 in EP7.0, USP 616
6. GB/T, GB/T1479.1-2011,GB/T5162-2006/ISO3953:1993;
List of Configuration for Measuring the Angle of Rest of Granules in Granules
Details of functions and parameters for each modelParameters
Function description/model
|
FT-102B
|
FT-102BA
|
FT-104BA
|
FT-104BC
|
1. Funnel:
|
Configuring multiple convertible cylindrical measuring cylindersfunnelComposition, funnel material isMade of stainless steel material
|
2. Convertible funnel diameterConvertible funnel diametermm:
|
Purchase: 2.5; 4.0; 5.0; 6.0; 7.0; 8.0; 9.0; 10;14; 15;16; 17;18; twenty-five
|
Standard configuration includes 5 standard5pcs
|
Standard configuration standard1 10mm funnelFunnel 1
|
Standard configuration includes 5 standard5pcs
|
3. Time RangeTime:
|
0-9999.9S settingsetThe accuracy isaccuracy0.1s
|
4Weighing:
|
0-2000.0g. Precision 0 1g
|
5. Funnel volumeFunnelVolume:
|
200ml
|
6. Receiving containerreceiving container
|
25ml, 100ml, 200ml, 250ml, 500ml (optional specifications according to user needs, standard configuration is 1)standard configurationis1pcs
|
7. Vibration densityTap density
|
|
0-999.999g/ml
|
|
0-999.999g/ml
|
8. Loose densityBulk density
|
0-999.999g/ml
|
9. Angle of reposeAngle of repose
|
|
|
0-90 degrees; 0.1 degreesdegrees
|
10. Resting angle discAngle of repose Disc
|
|
|
diameterDiameter100mm
|
11. Temperature and humidity rangeemperature and humidity
|
18-40 ℃ relative humidity at 35-80% relative humidity
|
12. Mass flow rateMass flow rate
|
0-999.99g/s
|
|
13. Volume flow rate Volume flow rate
|
0-999.99g/ml
|
|
14.printerprinter
|
Automatically print out test data and flow index
printerisautomatically print test data and flow index.
|
15.Mixing deviceMixing device
|
Automatic mixing and feeding function
Equipped with automatic mixingfeedingfunction
|
16. Power supplypower supply
|
220V±10%
|
17.chooseChoose
|
1 set of softwareChoosetobuy a set of PC software
|
Application Description:
1. Applied to research institutes, universities, production and processing upstream and downstream enterprise laboratories, as well as new product research and development, providing data basis for quality control
2. This series of models is designed with multiple models based on commonly used testing projects in the industry, meeting different industry requirements and saving costs for customers
List of Configuration for Measuring the Angle of Rest of Granules in Granules
Serial number
|
name
|
quantity
|
remarks
|
1
|
host
|
1 unit
|
|
2
|
Angle of repose disc
|
1 piece
|
Angle of repose test
|
3
|
funnel
|
1 piece
|
|
4
|
100ml stainless steel measuring cylinder
|
1 piece
|
Fixed volume method testing
|
5
|
Testing platform (with weighing)
|
1 set
|
|
6
|
Steel rule
|
1 piece
|
|
7
|
Brush brush
|
1 piece
|
|
8
|
250ml plastic measuring cup
|
1 piece
|
The use of fixed quality method and material acceptance
|
9
|
Instruction manual, warranty card, certificate of conformity
|
One copy
|
|
10
|
Feeding spoon (large)
|
1 piece
|
|
11
|
Mixing device
|
1 set
|
|