liquid caustic sodaMagnetic flap level gauge
Introduction:
1. Product Name:liquid caustic sodaMagnetic flap level gauge;
2. Model: UHZ series;
3. Measurement range: 300mm-10000mm;
4. Temperature range: -25-500;
5. Pressure range: ≥ 2.5Mpa;
6. Error: ± 10mm;
7. Connecting flange: Normal DN25;
8. Material: 304 lined with PTFE.
liquid caustic sodaMagnetic flap level gaugeWorking principle:
Using the principle of a connector, the liquid in the container is introduced into the main tube of the level gauge at an equal height. The floating ball component inside the main tube is based on the principles of buoyancy and magnetic coupling. When the liquid level in the tested container rises or falls, the float in the main tube of the level gauge also rises or falls accordingly. The long-lasting magnetic steel inside the float is transmitted to the on-site indicator through magnetic coupling, driving the red and white flip columns to flip 180 degrees. When the liquid level rises, the flip column changes from white to red, and when the liquid level drops, the flip column changes from red to white. The red and white boundary of the indicator is the actual height of the medium liquid level in the container, thus achieving the indication of the liquid level.
liquid caustic sodaMagnetic flap level gaugeCharacteristics:
It can be used for on-site or remote display and control of liquid level in high-temperature, explosion-proof, anti-corrosion, food and beverage, and other occasions. The UHZ series products can achieve high sealing, leak prevention, and reliable measurement of liquid level under high temperature, high pressure, high viscosity, and strong corrosive conditions. The entire measurement process has no blind spots, eye-catching display, intuitive readings, and a large measurement range. Equipped with liquid level alarm and control switch, it can achieve upper and lower limit alarm and control of liquid level or boundary. Equipped with liquid level transmitter, it can adjust the liquid level.
liquid caustic sodaMagnetic flap level gaugeSelection:
|
Series Model UHZ- |
Structural characteristics | Liquid receiving material |
measuring range (mm) |
Applicable medium conditions | Flange connection (mm) | Weight (kg) | |||||
|
temperature (℃) |
pressure (Mpa) |
density g/cm3 |
Viscosity (Pa.s) |
DN | PN |
basic weight |
lengthening basic weight |
||||
| C10 | Standard type |
1Cr18Ni 9Ti0Cr18Ni9 (304) |
300- 8000 |
-20 +150 |
0-2.45 | 0.5-2 | ≤0.04 | 25 |
1.0 1.6 |
6 | 5 |
| C11 | High pressure |
300- 8000 |
-20 +150 |
2.45-9.6 | 0.5-2 | ≤0.04 | 25 |
2.5 4.0 |
6 | 6 | |
| C12 |
High temperature type High pressure |
300- 8000 |
-20 +350 |
2.45-9.6 | 0.5-2 | ≤0.04 | 25 |
6.3 1.0 |
6 | 6 | |
| C13 |
Low temperature model (Frost proof type) |
300- 3500 |
>-40 | 0-2.45 | 0.5-2 | ≤0.04 | 25 |
1.6 2.5 |
6 | 7.5 | |
| C14 |
Liquid ammonia, liquid Fossil oil and gas specialized |
300- 15000 |
-20 +150 |
0-2.45 | 0.45-0.7 | ≤0.05 | 25 | 2.5 | 6.5 | 6 | |
| C15 | anti-corrosive |
00Cr17Ni14Mo2 (316L) |
300- 8000 |
-20 +150 |
0-2.45 | 0.5-2 | ≤0.04 | 25 | 1.6 | 6 | 5 |
| C16 |
Anti corrosion type( PP outer layer glass Fiberglass steel |
PP |
300- 5000 |
20 +100 |
0-0.6 | 0.5-2 | ≤0.04 | 32 | 1.6 | 3 | 3 |
| C17 |
Anti corrosion type( PVC outer layer Fiberglass reinforced plastic |
U-PVC |
300- 5000 |
20 +60 |
0-0.5 | 0.5-2 | ≤0.04 | 32 | 1.6 | 3 | 3 |
| C18 | Anticorrosive type | ABS |
300- 5000 |
-20 +120 |
0-0.6 | 0.5-2 | ≤0.04 | 32 | 1.0 | 3 | 3 |
| C19 |
Anti corrosion type( Stainless steel interior Lined with PP |
PP |
300- 15000 |
-20 +100 |
0-1.0 | 0.5-2 | ≤0.04 | 25 | 1.6 | 4 | 5 |
| C20 | Anticorrosive type | PE |
300- 5000 |
20 +40 |
0-0.6 | 0.5-2 | ≤0.04 | 25 | 1.6 | 6 | 7 |
| C21 |
Steam jacket Heating type |
1Cr18Ni9Ti |
300- 15000 |
-20 +150 |
0-2.45 | 0.5-2 | ≤0.05 | 32 | 1.6 | 6 | 8 |
| C22 |
high viscosity Medium type |
0Cr18Ni9 (304) |
300- 15000 |
-20 +150 |
0-2.45 | 0.5-2 | ≤0.05 | 32 | 1.6 | 6 | 5 |
| C23 |
Food Specialty Usage type |
1Cr18Ni9Ti |
300- 15000 |
-20 +150 |
0-1.6 | 0.5-2 | ≤0.05 | 50 | 1.6 | 7 | 5 |
| UHZ- | Content of supporting instruments and accessories | |||||||||||
| O | Blind flange, without drain valve | |||||||||||
| L | Bottom of the liquid level gauge is equipped with a drain valve | |||||||||||
|
|
O | No liquid level alarm switch | ||||||||||
|
|
H | High level alarm switch AK-3 type, with memory function, failure to troubleshoot, signal not eliminated | ||||||||||
|
|
L | Low level alarm switch AK-4 type, with memory function, failure to troubleshoot, signal not eliminated | ||||||||||
|
|
B | High and low alarm switches are fully equipped, with memory function for AK-3 and AK-4 models | ||||||||||
|
|
G | High level alarm switch, regional alarm AK-1 type |
One DF-1 type conversion amplifier is attached |
|||||||||
|
|
D | Low level alarm switch, regional alarm AK-1 type | ||||||||||
|
|
Q | High and low alarm switches are fully equipped, with two AK-1 regional alarms | ||||||||||
|
|
S | Integrated high and low position alarm switch, regional alarm AK-2 type | ||||||||||
|
|
|
O | No liquid level control switch | |||||||||
|
|
|
H | Upper limit control switch, single point spring CK-1 type | |||||||||
|
|
|
L | Lower limit control switch, single point spring CK-1 type | |||||||||
|
|
|
B | Fully equipped with upper and lower limit control switches, single point dry spring CK-1 type two sets | |||||||||
|
|
|
W | Integrated upper and lower limit control switches, dual point spring CK-2 type | |||||||||
|
|
|
T | Upper limit control switch, Hall sensor CK-3 type | |||||||||
|
|
|
L | Lower limit control switch, Hall sensor CK-4 type | |||||||||
|
|
|
E | Fully equipped with upper and lower limit control switches, Hall sensor CK-3 type two sets | |||||||||
|
|
|
C | Integrated upper and lower limit control switches, Hall sensor CK-4 type | |||||||||
|
|
|
|
O | No remote transmission transmitter device | ||||||||
|
|
|
|
R | Equipped with LB type bundled transmitter, output two-wire 4-20mADC | ||||||||
|
|
|
|
S | Static pressure remote transmitter, (URS-100) output two-wire 4-20mADC | ||||||||
|
|
|
|
|
O | Ordinary waterproof type | |||||||
|
|
|
|
|
B | Inherent reassuring IB II CT4, can be equipped with Zener reassuring gate or IS4041 Ex isolation gate | |||||||
|
|
|
|
|
Bd | Explosion proof type d Ⅱ CT4 | |||||||
|
|
|
|
|
|
O | Not suitable for remote transmission display instrument | ||||||
|
|
|
|
|
|
A | Digital and light column display adjustment alarm XGTH-510 (vertical) | ||||||
|
|
|
|
|
|
B | Digital and light column display adjustment alarm XGTA-810 (horizontal) | ||||||
|
|
|
|
|
|
C | Digital display adjustment alarm XMTA-810 (horizontal) | ||||||
|
|
|
|
|
|
E | Double column liquid level display instrument XGH-202 (vertical) | ||||||
|
|
|
|
|
|
D | Intelligent liquid level/capacity (weight) display regulator XMT-620 (horizontal) | ||||||
|
|
|
|
|
|
|
-□□□□ | Measurement range (mm) | |||||
|
|
|
|
|
|
|
|
-□□ | Medium density (g/cm3) | ||||
|
|
|
|
|
|
|
|
|
- | D | Open pressure container | ||
|
|
|
|
|
|
|
|
|
□ | Work pressure (MPa) | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|