On December 1, 2017, the National Energy Administration made corresponding adjustments to the qualification equipment for power testing. The qualification equipment for testing in each province and region is the same, and some equipment that is not commonly used by power enterprises in actual work is omitted. Huatian Power briefly introduced the new version of the construction equipment selection guide required for the installation (repair, testing) and testing of Level 4 power facilities license.
Obtaining a Level 4 Installation (Repair, Testing) License, one can engage in the installation, maintenance, or testing activities of power facilities with voltage levels below 35 kV.
To learn about the application materials and filling specifications for the installation, maintenance, and testing of power facility licenses, you can click on "Application Specifications" to browse.
Product nickname: Level 4 testing instrument, Level 4 testing equipment, Testing instrument equipment, Level 4 testing configuration table, Level 4 testing equipment, Level 4 testing and inspection equipment selection table.
Serial Number | Name of machinery and equipment | unit | quantity | specifications | model |
one | High voltage generating equipment | ||||
1 | DC high voltage generator | cover | 1 | DC:120kV/2mA | ZGS-120kV/2mA |
2 |
Power frequency withstand voltage test device |
cover | 1 |
AC:30kVA/50kV | YDJ-30kVA/50kV |
cover | 1 | AC:6kVA-10kVA/50kV | YDJ-10kVA/50kV | ||
3 | Complete set of equipment for frequency conversion series resonance test | cover | 1 |
75kVA/75kV/1A30~300Hz |
XZB-75kVA/75kV |
4 | Induction voltage withstand test device | cover | 1 | 5kVA/360V 150Hz | SFQ-5kVA/500V |
two | Electrical measuring instruments | ||||
1 |
High voltage dielectric loss tester |
tower | 1 |
1. The accuracy of medium measurement is 1% 2. The capacitance accuracy is 0.5% 3. Anti interference frequency conversion |
JS-H |
2 |
Three phase relay protection tester | tower | 1 | Two sets of three-phase voltage and current each | HY331 |
3 | Loop resistance tester | tower | 1 | DC:≥100A | HLY-100A |
4 | Transformer volt ampere characteristic tester | tower | 1 | 500V/5A | FA-103 |
5 | Ground Resistance Tester | tower | 1 | DER2571 | |
6 | Transformer DC resistance tester | tower | 1 | DC:≥10A | ZZC-10A |
7 | Circuit breaker characteristic tester | tower | 1 | Digital 0.5 level | BBC-H |
8 | Circuit breaker characteristic tester | tower | 1 | GKC-H | |
9 | insulation resistance tester | tower | 1 | DC: 0~5000V 200G (Ω), short-circuit current ≥ 3mA |
BC2010 |
three | Common Instrument List | ||||
1 | Megger | only | 1 | DC:2500V | DMG2671 |
2 | Megger | only | 1 | DC:500V | DMG2670 |
3 | Digital dual clamp phase voltmeter | only | 1 | Measure current 1mA~5A | SMG2000B |
Note:1. The appearance of the product is subject to the actual product. Technical parameters and models are subject to change without prior notice. If there is any act of theft or copying, legal responsibility will be pursued
2. To learn more about Huayi products, please enter the product center. Service Hotline:
Those who have obtained the license for the installation (repair, testing) of fourth level testing electrical facilities can undertake the testing of transmission, power supply, and power receiving electrical facilities with voltage levels below 35 kV. The applicant for the license for the installation (repair, testing) of electrical facilities in the fourth level testing category shall meet the following conditions:
(1) Having legal personality and a well-established organizational structure;
(2) The registered capital shall not be less than 8 million yuan, and the net assets shall be over 9.6 million yuan;
(3) The technical leader has more than 3 years of experience in power facility testing management and holds a professional technical qualification of power engineering or above;
(4) There shall be no less than 20 technical and economic professionals (including senior technicians, technicians, and senior engineers), including no less than 10 senior engineers, engineers, and engineering technicians in the field of electrical engineering;
(5) Establish a safety management organization, with safety engineers holding professional technical qualifications at or above the level of electrical engineering engineer; At least one part-time safety supervisor shall be appointed;
(6) A fixed business premises with a total area of not less than 600 square meters, equipped with various professional laboratories and testing equipment capable of testing transmission, power supply, and power receiving facilities with voltage levels below 35 kV;
(7) Having a sound technical archive management system;
Product Attachment Diagram
-
Huayi Electric Power specializes in the research and development of power installation and testing equipment
-
Huayi Electric Power specializes in the research and development of power installation and testing equipment
-
Huayi Electric Power specializes in the research and development of power installation and testing equipment
-
Huayi Electric Power specializes in the research and development of power installation and testing equipment