Laboratory glassware automatic cleaning and disinfection machine/bottle washing machine
Laboratory glassware automatic cleaning and disinfection machine/bottle washing machine
Product details

Laboratory glassware automatic cleaning and disinfection machine/bottle washing machine. As our demand for experimental data accuracy becomes increasingly high, cleaning and drying glassware becomes very important. The cleaning process must ensure that the vessel is not affected by the previous use in the next use. The laboratory glassware automatic cleaning and disinfection machine/bottle washing machine not only frees researchers from labor-intensive cleaning work, but also provides replicable and more efficient cleaning results.

1. Laboratory environmental conditions:
The laboratory used for installing instruments should have a good external environment. The laboratory should be located in a place without strong electromagnetic fields and strong thermal radiation sources nearby, and should not be built near equipment and workshops that generate severe vibrations. It should avoid direct sunlight, smoke, polluted airflow, and water vapor.
The internal environment of the laboratory should be kept clean, with an indoor temperature controlled between 0-40 ℃ and a relative humidity of less than 70%.
2. Laboratory equipment conditions:
The volume of the instrument host is 760m × 980m × 1100m (length x width x height), and a distance of no less than 0.5 meters from the wall should be left around the bottle washing machine for your operation and future maintenance.
The laboratory should be equipped with tap water (similar to a fully automatic washing machine). The tap water pressure should not be less than 0.1MPA. If two pure water washes are required, a pure water source (not less than 60L water bucket) should be provided. The instrument has been equipped with a booster pump for water inlet. The instrument is equipped with a 4-wire water distribution pipe at the factory.
3. Laboratory power distribution requirements:
The laboratory should be equipped with AC 220V, and its incoming wire diameter should not be less than 4mm2. Require a single-phase air protection switch with a capacity of 32A to be connected. The instrument has an exposed cable of 5 meters,
4. Instrument requirements:
(1) Two water sources are required: tap water requires a 4-point external thread interface, pure water tanks or pipelines require a 4-point external thread, and the inlet pipe length is 2 meters.
(2) Require there to be drainage near the instrument, which should be the same as the drainage pipe of the washing machine. The length of the drainage pipe should be 2 meters, and the height of the drainage outlet should not exceed 0.5 meters.
5. The instrument should be reliably grounded:
The ground wire should be led out directly from a metal copper plate buried underground at a depth of less than 1 meter and connected to the ground wire end of the power supply incoming line.
6. Specific parameters of bottle washing machine

power supply power supply
Voltage 220V, heating power 4.5Kw Voltage 220V, heating power 6.5Kw
program program
Customizable programming; Ten pre made programs Customizable programming; Ten pre made programs
Cleaning function Cleaning function
Circulating pump (maximum flow rate) 400L/min Circulating pump (maximum flow rate) 400L/min
water softener water softener
Non pressure ion water booster pump Non pressure ion water booster pump
Cleaning agent dispensing pump Cleaning agent dispensing pump
Neutralizing agent dispensing pump Neutralizing agent dispensing pump
Cleaning powder dispenser Cleaning powder dispenser
Cleaning agent dispenser Cleaning agent dispenser
Efficient condenser Efficient condenser
control system control system
Microcomputer Control Technology+Optical Isolation Circuit Design Microcomputer Control Technology+Optical Isolation Circuit Design
Electronic safety lock Electronic safety lock
Over Temperature Protection Over Temperature Protection
Overflow protection Overflow protection
Delay start Delay start
RS232 interface RS232 interface
material material
Inner cavity material 316 stainless steel Inner cavity material 316 stainless steel
Shell material: 306 stainless steel Shell material: 306 stainless steel
Upper spray arm made of 316 stainless steel Upper spray arm made of 316 stainless steel
Lower spray arm made of 316 stainless steel Lower spray arm made of 316 stainless steel
Compressed air drying component
Power 2Kw Air Flow (m3/h) 55 HEPA Filter
Dimensions (Depth X Width X Height) Dimensions (Depth X Width X Height)
Appearance: 788X730X1673 Interior: 680X555X730 Appearance: 780X700X1000 Interior: 690X560X540
Cleaning basket Cleaning basket
42 200ml conical flasks or 250ml volumetric flasks 42 200ml conical flasks or 250ml volumetric flasks