The genuine turbine flow sensor is sold at a discounted price with guaranteed quality. Minghong Automation Instrument Co., Ltd. adheres to the principle of survival through reputation and development through service, and has won the trust of many customers at home and abroad.
1、 Overview Description:LWSSanitary turbine flowmeter is a flow measuring instrument that can be widely used in industries such as pharmaceuticals, food, and beverages, as a measuring, ingredient, control, and finished product filling device. The instrument casing is made of stainless steel(316L)Made with special materials for the movement, it has excellent anti-corrosion and rust prevention capabilities. The overall structure of the instrument breaks through traditional techniques and adopts advanced structural optimization design from abroad, greatly improving the accuracy and repeatability of the instrument. Specially designed for the pharmaceutical and beverage industries, using a quick connect structure for easy cleaning.LWSThe series of sanitary turbine flow meters have reached the international standard of similar products and are ideal instruments for the sanitary industry.
2、 Applicable occasions:304、316Material, easy to disassemble, corrosion-resistant, suitable for the food manufacturing industry, Pharmaceutical industry:Filling and metering of infusion products such as saline and glucose water. Food and beverage industry:Filling and measuring of liquid foods such as vegetable juice, fruit juice, beer, and finished oil.
Product Description:LWGYThe type turbine flow sensor is a precision flow measurement instrument suitable for measuring low viscosity media such as water, diesel, gasoline, etc. It can be used to measure the flow rate and total amount of liquids when paired with corresponding flow accumulation instruments. Widely used in the fields of petroleum, chemical, metallurgy, scientific research and other metrology and control systems. Sensors are available in regular, high-precision, and wear-resistant types(Hard alloy)Waiting for various forms. There are two types of amplifiers: ordinary and explosion-proof. This sensor can also be used withLRT-IUsed in conjunction with the on-site flow accumulation table(Powered by lithium batteries,1Annual battery replacement).
main features
International standards that can replace similar imported products;
Anti corrosion and anti rust materials, suitable for the hygiene industry;
Quick installation structure, easy to install and maintain;
High precision and good repeatability;
High quality turbine, beyond the conventional range;
High precision0.2%, 0.5%, 1%Accuracy optional
Wear resistant Hard alloy shafts and bearings, suitable for media with impurities such as sand particles
Corrosion resistance Suitable for corrosive media such as seawater, ammonia water, acetic acid, etc
. Bidirectional There are bidirectional turbine flow meters available for selection. Suitable for measuring the inflow and outflow of oil depots.
Multiple outputs Pulse,4~20mADCAccumulated on-site/Instantaneous display
Wide power range 5~24VDC
Explosion proofdⅡBT4(onlyLRT-I)
. Diameter2*,4*,6,10,15,20,25,32,40,50mm
1.Basic parameters:
Instrument caliber 4、6、10、15、20、25、32、40 、50
accuracy class ±1%R、 ±0.5%R、 ±0.2%R(Special design required)
Range ratio1:10;1:15;1:20
Instrument material 304、316(L)Stainless steel
Temperature of the tested medium (℃) -20~+120℃
environmental condition Temperature -10~+55℃, relative humidity5%~90%Atmospheric pressure86~106Kpa
output signal Sensor: Pulse frequency signal, low level ≤0.8VHigh level ≥8V
Transmitter: Two wire system4 ~ 20mADCcurrent signal
power supply Sensor:+12VDC、+24VDC(Optional)
Transmitter:+24VDC
On site display type: instrument built-in3.2Vlithium battery
Signal transmission lineSTVPV3×0.3(Three wire system),2×0.3(Second line system)
Distance ≤1000m
Signal line interface Basic type: Hausman connector or self-contained three core cable; Explosion proof type: Internal threadM20×1.5
Explosion proof grade Basic type: non explosion proof product; Explosion proof type:ExdIIBT6
protection gradeIP65
2.Measurement range and work pressure
Caliber(mm) Normal flow rangem3/h)Expand traffic range(m3/h)Conventional stress tolerance(MPa)
DN 4 0.04~0.25 0.04~0.4 1.0
DN 6 0.1~0.6 0.06~0.6 1.0
DN 10 0.2~1.2 0.15~1.5 1.0
DN 15 0.6~6 0.4~8 1.0
DN 20 0.8~8 0.45~9 1.0
DN 25 1~10 0.5~10 1.0
DN 32 1.5~15 0.8~15 1.0
DN 40 2~20 1~20 1.0
DN 50 4~40 2~40 1.0