Pure sine wave output with distortion rate below 3%. Can meet the electricity needs of the vast majority of electrical appliances, with high conversion efficiency and low noise |
The charging current of the mains is adjustable from 0-30A, with stable voltage and frequency output, supporting diesel (gasoline) generators |
Special DSP chip design, ring transformer, low loss, high efficiency, faster and more stable machine operation |
|
Inverter priority, mains priority, energy-saving mode Conversion time ≤ 4ms |
New fault code query function, LCD display screen, RS232/RS485 communication interface, convenient for real-time monitoring |
Battery undervoltage alarm protection, battery overvoltage alarm protection, overload power protection, inverter output short circuit protection, over temperature protection |
![]() |
Priority given to mains electricity When the mains power is normal (within the input voltage range of the machine's mains power), the mains power not only charges the battery, but also outputs stable AC power after being stabilized; When the mains power is abnormal (the mains power exceeds the working range of the machine or is interrupted), the machine switches to battery inverter power supply. |
|
![]() |
Inverter priority When the battery is fully charged (i.e. the voltage of a conventional single cell battery is 13.2VDC), even if the mains input is normal, the machine will switch to battery inverter power supply; When the battery voltage is low (i.e. the voltage of a conventional single cell battery is below 11VDC) and the mains input is normal, the machine switches to mains mode for power supply. When the mains and PV are normal, the mains and solar controller charge the battery simultaneously. |
|
![]() |
Power Saving Mode The machine operates in battery inverter mode (ineffective in mains mode). When the load is below 10% of the rated load, the inverter will start and stop at regular intervals to save battery energy (i.e. the machine will intermittently interrupt the inverter output); When the load exceeds 10% of the rated load, the inverter will continue to operate in the inverter state (i.e. the machine will not intermittently interrupt the inverter output). |
Attention: In the mains priority/inverter priority mode, when the mains charging current is not set to 0A, the mains can charge the battery; When the charging current of the mains is set to 0A, the mains does not charge the battery, only the solar controller charges the battery.
| Technical Specifications | |||||||
| Model LS-T | 10212/24 | 20212/24/48 | 30224/48 | 40224/48 | 50248 | 60248 | |
| rated power | 1000W | 2000W | 3000W | 4000W | 5000W | 6000W | |
| battery voltage | 12/24VDC | 12/24/48VDC | 24/48VDC | 48VDC | |||
| Machine size (L * W * Hmm) | 490*300*130 | 510*320*130 | |||||
| Packaging size (L * W * Hmm) | 565*395*225 | 585*415*225 | |||||
| Net weight (kg) | 11.5 | 17.5 | 19.5 | 21.5 | 23.5 | 25.5 | |
| Gross weight (kg) (cardboard packaging) | 13 | 19 | 21 | 23 | 25 | 27 | |
| General Parameters | |||||||
| input | DC input voltage range | 10.5-15VDC (single battery voltage) | |||||
| Range of mains input voltage | 85VAC~138VAC /89VAC~144VAC / 93VAC~150VAC / 170VAC~275VAC / 178VAC~288VAC /186VAC~300VAC | ||||||
| Frequency range of mains power input | 45Hz~65Hz | ||||||
| output | Inverter output efficiency | ≥85% | |||||
| Inverter output voltage | 110VAC±2% / 115VAC±2% / 120VAC±2% / 220VAC±2% / 230VAC±2% / 240VAC±2% | ||||||
| Inverter output frequency | 50/60Hz±1% | ||||||
| Inverted output waveform | sine wave | ||||||
| Output voltage range of mains power | 110VAC±10% / 115VAC±10% / 120VAC±10% / 220VAC±10% / 230VAC±10% / 240VAC±10% | ||||||
| Frequency range of mains power output | automatic tracking | ||||||
| Built in Sun Capable of controlling |
Charging mode | MPPT or PWM | |||||
| charging current | 10A,20A,30A,40A,50A,60A | ||||||
| Photovoltaic input voltage range | 12V system: 15V-44V; 24V system: 30V-44V; 48V system: 60V-88V | ||||||
| Maximum photovoltaic input voltage (Under 25 ° C conditions) |
12V/24V system: 50V; 48V system: 100V | ||||||
| Maximum photovoltaic input power | 12V system: 140W, 280W, 420W, 560W, 700W, 840W; 24V system: 280W, 560W, 840W, 1120W, 1400W, 1680W; 48V system: 560W, 1120W, 1680W, 2240W, 2800W, 3360W |
||||||
| working mode | Inverter priority/mains priority/energy-saving mode | ||||||
| Municipal power charging current (adjustable) | 0~30A | ||||||
| Convert time | ≤4ms | ||||||
| panel display | LCD | ||||||
| cooling method | Temperature controlled fan | ||||||
| Battery type (optional) | Sealed lead-acid battery | Average charging voltage: 14V; float charging voltage: 13.8V (single battery voltage, 24V: x2; 48V: x4) | |||||
| Open ended lead-acid battery | Average charging voltage: 14.2V; Floating charging voltage: 13.8V (single battery voltage, 24V: x2; 48V: x4) | ||||||
| lithium battery | Average charging voltage: 13V; floating charging voltage: 12.6V (single battery voltage, 24V: x2; 48V: x4) | ||||||
| Remarks | Users can customize charging parameters for other types of batteries | ||||||
| protect | Overload/overcurrent/short circuit/high temperature/anti reverse protection | ||||||
| communication | RS232/RS485 communication interface (optional) | ||||||
| environment | noise | ≤55dB | |||||
| temperature | -10℃~40℃ | ||||||
| relative humidity | 0%~95%, no condensation | ||||||