Demada Precision Instrument Co., Ltd
Home>Products>LMIX2 magnetic grid ruler
Product Groups
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    13962107506
  • Address
    Room B-401, Chengjian Building, 185 Jumao Road, Xiangcheng District, Suzhou
Contact Now
LMIX2 magnetic grid ruler
LMIX2 magnetic grid ruler
Product details
  • LMIX series
  • Marked pulse
  • Resolution=0025 mm (when divided by four times);
    0.1 mm (single frequency division)
  • Repetitive accuracy+/-0.025 mm
  • Small sensor reading head with built-in reading electronic components
  • Square wave signal speed ratio output

LMIX2 Technical Data

resolving power

When dividing by one, 0.1 mm; 0.025 mm at quadruple division

Repetitive accuracy

+/- 0.025 mm

System accuracy µ m at 20 ° C

+/-(25+20 x L) (L=length, meters)

Sensor/magnetic ruler distance

Max 2.0 mm

Shell

Die cast zinc alloy

Protection level

IP 67

Operating temperature

-10 ... + 70 ° C (-25...+85 ° C as required)

Storage temperature

-25 ... + 85 °C

Output current

Maximum 20 mA per band

Marking pulse (every 5 mm)

The cycle time depends on the operating speed

When the voltage is 5 VDC/5 V-TTL line driver output

Error/working voltage

+/-2.5%, standing wave coefficient<50 mV

Current consumption

Maximum 200 mA

output frequency

40 kHz (per band)

running speed

Max 4.0 meters per second

Maximum cable length

10 m

When the working voltage is 10-30 VDC/5 V-TTL line driver output

Error/working voltage

Stable, with a maximum standing wave coefficient of 5%

Current consumption

Maximum 150 mA

output frequency

40 kHz (per band)

running speed

Maximum 4 meters per second

Maximum cable length

50 m

Working voltage 10-30 VDC/10-30 VDC output

Error/working voltage

Stable, with a maximum standing wave coefficient of 5%

Current consumption

Maximum 150 mA

output frequency

Under ideal reading conditions, 40 kHz (per band)

running speed

Under ideal circumstances of dereliction of duty, the maximum speed is 4 meters per second

Maximum cable length

30 m

LMIX3 Technical Data

working voltage

10-30 VDC stable, with a maximum standing wave coefficient of 5%; 5 VDC+/-2.5%, standing wave coefficient<50mV

Current consumption

Maximum 150 mA (voltage 10-30 V); Maximum 200 mA (voltage 5 VDC)

Output terminal

Push pull type, reverse signal anti continuous short circuit, band A/A ', B /B‘, Z /Z‘

signal level

10-30 V or 5 V-TTL

Flag pulse

Every 5 mm

Repetitive accuracy

+/- 0.025 mm

System accuracy at 20 ° C, μ m:

+/-(25+20 x L) (L=measured length, meters)

resolving power

0.1 mm (single frequency), 0.025 mm (4th harmonic)

speed

Maximum 4 m/s -5V/TTL; Maximum 4 m/s -10-30V/HTL (at optimal reading)

output frequency

40 kHz each/band A/B/A '/B‘

Measure length

Maximum 32.0 meters

Sensor/magnetic ruler distance

Max 2.0 mm

Operating temperature

-10 ... + 70 °C (-25 ... +85 °C

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!