Karl Fischer moisture analyzer
The HI903 Karl Fischer titration instrument has a measurement range of 100ppm~100% moisture content. For professionals who need to accurately determin
Product details

The spacious LCD display screen is easy to read titration methods and related information, and can display real-time curves to follow the titration process. After the titration is completed, all data can be automatically saved and processedUSBCopy the interface toUIn a disk or computer.

Built in magnetic stirrer, fully sealed titration container, reducing the impact of environmental humidity on the results. The replaceable burette is convenient for changing the titrant at any time, and the built-in air pump can replace the organic solvent in the titration beaker in just a few seconds, saving experimental time.

The instrument can be connected to keyboards, scales, and printers、 USBstorage device、 PC、VGAExternal devices such as monitors facilitate data transmission, software upgrades, improve your work efficiency, and strengthen laboratory data management

HI903 Karl Fischer Moisture AnalyzerIt is an automatic titrator with flexible functions that can accurately measure the moisture content in samples. It can automatically add titration standard solution and detect the endpoint of titration reaction with dual platinum needle electrodes. The instrument is equipped with multiple moisture analysis methods, including different types of samples, and can store up to instrument methods and user-defined methods100It can be used in fields such as food, beverages, cosmetics, chemicals, pharmaceuticals, petroleum and petrochemical manufacturing.

HI903-400-10.jpg

Dynamic titration function

The dynamic titration function allows the titrator to adjust the titration volume based on changes in MV values, resulting in more accurate results.
This provides a larger dose near the start of titration and a smaller, more precise dose near the endpoint of titration.
Offset [drift] compensation

HI903Karl FischerVolumetric methodThe titrator can automatically adjust the titration calculation to take into account the influence of any environmental humidity entering the titration cup.

By correcting for water that does not exist in the actual sample, this provides more accurate results.

Average value of titration results

The continuous measurement results of the Karl Fischer titration instrument can choose the average of multiple measurement values.

Titration information storage and preservation

HI903The Karl Fischer titration database can store information on 20 types of titrants, which can remind users to calibrate the concentration of the standard solution at regular intervals and reduce measurement errors.

Optional endpoint mode

HI903SelectHI76320The dual platinum needle polarized electrode automatically detects the endpoint, and users can choose the MV value based on the mV stabilization time or drift rate.

Pre titration process

The pre titration process can eliminate solvent and residual moisture in the beaker, and can keep the solvent dry in standby mode.

Burette and measuring system

HI903-400-02.jpg

Precision metering pump

Our unparalleled40,000The piston driven pump can conveniently add extremely small and high-precision titrants or reagents.

Chemical resistant pipes

The suction and separation pipes are made of durable and chemically resistant materialsPTFEMade and equipped with a light blocking polyurethane jacket to protect the photosensitive reagent.


Unique burette*

Specially designed anti diffusion burette *, specially designed glass burette *, can accurately deliver titrants to high turbulence mixing areas, ensuring rapid reaction;
Prevent the titrant from diffusing into the solvent in the beaker.

Titration and solvent system

HI903-400-05.jpg

Efficient sample processing

HI903Equipped with a quick sample port and replaceable rubber spacer, the sample can be quickly added to the solvent in the beaker through the movable partition on the titration container cover.
The integrated magnetic stirrer ensures uniformity, thereby achieving accurate and rapid reactions.


Chemical resistant titration container

Glass and PTFE titration cups and accessories are designed to withstand the harsh solvents and reagents involved in Karl Fischer titration.


Sealed solvent system

The titration container is completely sealed,Keep the system dry and reduce the consumption of titrants, while saving time between titrations,Prevent moisture in the environment from affecting experimental results.

The solvent can be replaced within seconds without opening the titration container.


Color developing desiccant

Colorable and reusable silicone desiccants can be used to determine whether replacement is necessary based on color changes.

Titimeter data management

HI903-400-12.jpg

FlexibleGLPLaboratory data management can store operational information for each sample, including sample identification, company and operator names, date and time, electrode numbers, calibration information, etc

Highlight your most important information.

Easily transfer experimental data throughUSBThe data cable can import dataPCEnd (required)HI900PCSoftware), or directly saved in the built-inUSBIn the flash drive

The final report is customizable, so you can ensure that you view and store the most important information.

The instrument can be connected to keyboards, scales, and printers、 USBstorage device、 PC、VGAExternal devices such as displays are used for data transmission and printing.

Interface and Display

Display complete information

A large color LCD screen that displays all the information you know, including methods, titration results, units, titration volumes, offsets, MV values, etc

Real time titration curve tracking

Real time titration curves can help you quickly identify patterns and issues that may arise during the analysis process

Easy Titimeter Menu

Custom keys allow you to navigate clearly between screens, facilitating quick retrieval operations

HI903 Karl Fischer Moisture AnalyzerTitration technical indicators

measuring range

100ppm~100%

resolution

1ppm~0.0001%

Measurement unit

%The ppm、mg / g、μg/ g、mg、μg、mg / mL、μg/ mL、mg / pc、μg/ pc

Type

Liquid or solid

Pre titration adjustment

automatic

Background drift correction

Automatic or user-defined

Endpoint criteria

FixedmVContinuous value, relative drift stops or absolute drift stops

Quantitative dosing

Dynamic titration, optional pre titration speed

Result statistics

Mean value, standard deviation

Titration metering system

Resolution of metering pump

1/40000Burette volume【0.125 μL/Next time, use5 mLburette

Accuracy of metering pump

±0.1% Burette volume

Syringe [burette]

5 mLPrecision glass injectorPolytetrafluoroethylene【PTFE piston

valve

electric3 Open valvePolytetrafluoroethylene【PTFE】Liquid contact materials

catheter

Polytetrafluoroethylene【PTFE】Material, with insulation and light shielding protective cover

Titration dosing tube*

Glass material, fixed position, anti diffusion

titration vessel

Cone shaped, volume50 to 150 mL

Solvent treatment system

Sealed system, built-in diaphragm air pump

Electrode technical indicators

electrode type

HI76320 Dual platinum needle polarized electrode, interface type:BNC

polarization current

1. 2, 5, 10, 15, 20, 30Or40μA

Voltage range

2 mV to 1000 mV,resolution:0.1 mV,accuracy@25ºC/77ºF:±0.1%

Other technical indicators

Programmable mixer

Magnetic stirrer, optical adjustment, digital stirrer; Speed range:200 to 2000 rpm、resolution100 rpm

measuring method

up to100 Methods (standard and user-defined)

Data Storage

Can store up to100 Titration report and drift rate report

GLPfunction

Good laboratory data management, storage and printing of data

Display screen function

5.7Inches【320 x 240Pixel ColorLCD

language selection

English, Portuguese, Spanish

application environment

10 to 40°C(50 to 104°F),max95%RH

Power Mode

AC100-230Vpower supply

Dimension Host size:390 x 350 x 380 mm (15.3 x 13.8 x 14.9 in)
Weight:10 kg (22 lbs.)