Product Introduction
KZ-TH-80 Drug Stability Test Chamber Directly Sold by Kezheng Instrument Manufacturer
Product Features:
The drug stability test chamber adopts an imported high stability controller, high stability platinum temperature measurement antibody, LCD Chinese and English touch screen, 120 sets of 1200 segment programming, and 999 cycle settings. Equipped with multiple sets of PID control functions and a wind circulation system that meets temperature/humidity testing standards, it can simulate testing conditions in different environments such as high temperature and high humidity/high temperature and low humidity/low temperature and high humidity/low temperature and low humidity. It is also paired with a programming system that is easy to operate and learn with high accuracy, providing the best testing performance.
Compliant with standards: GB/T5170.5-2008, GB/T10586-2006, GB/T2423.1-2008 Test A, GB/T2423.2-2008 Test B, GB/T2423.3-2006 Test Ca, GB/T2423.4-2008 Test.
Specifications:
model |
KZ-TH-80 |
KZ-TH-150 |
KZ-TH-225 (A~D) |
KZ-TH-408 |
KZ-TH-800 |
KZ-TH-1000 |
|||||
Internal dimensions W × H × D (cm) |
40×50×40 |
50×60×50 |
60×75×50 |
60×85×80 |
100×100×80 |
100×100×100 |
|||||
External dimensions W × H × D (cm) |
120×165×115 |
130×170×125 |
140×185×130 |
165×195×155 |
185×200×175 |
190×210×185 |
|||||
temperature range |
Low temperature: (A: -20 ℃; B:-40℃; C:-60℃; D: -70 ℃/(High temperature: 100 ℃ (150 ℃)) |
||||||||||
Temperature analysis accuracy/ |
0.1℃/±2.0℃ |
||||||||||
Temperature control accuracy |
±0.5℃ |
||||||||||
Heating/cooling time |
Raise the temperature by about 4.0 ℃/minute; Cooling down by about 1.0 ℃/minute |
||||||||||
Internal and external materials |
The material of the inner and outer boxes is SUS304 # stainless steel plate (the outer box can be selected with baked paint) |
||||||||||
Insulation material |
High temperature resistant and high-density vinyl chloride acetate foam insulator material |
||||||||||
cooling system |
Air cooled/single-stage compressor (-20 ℃); Double stage compressor (-40 ℃ -70 ℃) |
||||||||||
protective device |
Non fuse switch, compressor overload protection, refrigerant high and low pressure protection, over humidity and over temperature protection |
||||||||||
Accessories |
Built in glass door for operation hole (optional), recorder (optional), observation window, 50mm test hole, |
||||||||||
power supply |
AC220V ,50/60Hz & 1∮ , AC380V ,50/60Hz 3∮ |
||||||||||
Weight (approximately) |
150KG |
180KG |
250KG |
350KG |
500KG |
520KG |
|||||
*The drug stability test chamber can be made according to the size requirements of customers to meet their needs.

Real photos taken: