KSPY-7000gas chromatograph
The KKSP-7000 series gas chromatograph is a computerized, high-performance, and multi-purpose intelligent gas chromatograph designed and produced by our company to meet the requirements of chromatographic users. Multiple detector combinations can be selected according to the needs to meet the requirements of ordinary laboratories, daily production, routine detection, and trace and trace analysis. It is widely used in various fields such as petroleum, chemical, pesticide, environmental protection, epidemic prevention, medicine, electricity, scientific research, and education.
Main performance characteristics:
1. Excellent column box performance, can achieve true near room temperature operation, can perform five step programmed heating, has column box automatic cooling and rear door opening function, fast cooling speed, and achieves rapid cooling.
2. It has six independent control areas: column box, capillary injector, packed column injector, detector, thermal conductivity cell, and auxiliary device.
3. The instrument is equipped with a dedicated capillary injection port and two packed column injection ports, which can simultaneously accommodate two gas path systems: packed column and capillary column. It can meet the current requirements for the selection and analysis of various chromatographic columns in chromatographic analysis.
4. The instrument has a dual gas path, triple injector, and dual packed column system structure, which can effectively suppress baseline fluctuations and drift in real time and is suitable for programmed temperature analysis.
5. The keyboard is used to set various control and usage parameters (including detector operation parameters), and the machine has functions such as self diagnosis, power-off protection, file storage and retrieval, and extreme temperature setting. It can accurately display various temperature control settings, actual values, TCD bridge current, FID amplifier sensitivity, retention and analysis time, etc.
6. Multiple detector combinations can be selected according to usage requirements: FID, TCD, FPD, ECD, NPD, etc.
7. Adopting LCD display, the display content is rich, intuitive, and easy to operate.
8. Selecting well-known domestic and foreign electrical components and carefully selecting them, coupled with precise calibrated pneumatic control valves, ensures the reliability, stability, and high sensitivity of the instrument.
Main technical indicators:
◆ Temperature control:
Temperature control range: 6 ℃ -400 ℃ at room temperature
Temperature control accuracy: Soil 0.01 ℃
Temperature control channels: 5 channels (expandable to 6 channels)
Program heating order: 5 orders
Cheng Sheng rate: 0.1 ℃ -50 ℃/min
Time setting: 0-9999.9/min
Flame ionization detector (FID): (n-hexadecane)
Detection limit:Mt≤5×10-12g/s
Baseline noise:≤6×10-14A
Baseline drift:≤6×10-13A/h
Linear range:≥106
Thermal conductivity detector (TCD): (n-hexadecane)
Sensitivity: S≥5000mv.ml/mg
Baseline noise: ≤ 20uv
Baseline drift: ≤ 30uv/h
Linear range:≥104