Due to the low conductivity of pure water, it is not recommended to use itElectromagnetic Flowmeter(Unless for special electromagnetic applications), this opinion is for reference only. If there are any doubts, please let us know
Pure water flowmetercharacteristic:
High precision, ± 1%, ± 0.5%, ± 0.2%.
Good repeatability, short-term repeatability can reach 0.05% to 0.2%, making it a preferred flowmeter for trade settlement.
Output pulse frequency signal, suitable for total measurement and computer connection, no zero drift, strong anti-interference ability.
◆ It can obtain a good frequency signal (3-4kHz) with strong signal resolution.
◆ Compact and lightweight structure, easy installation and maintenance, and high circulation capacity.
Suitable for high voltage measurement, the instrument body does not require openings and is easy to make into a high voltage type instrument.
Pure water flowmeterAttention should be paid when using:
(1) Require the tested medium to be clean, with low viscosity, low corrosiveness, and free of impurities to reduce wear on the bearings. If the measured liquid gas or contains gas, a gas eliminator should be installed in front of the flowmeter. To prevent impurities from entering the transmitter and damaging it, as well as to prevent the turbine from getting stuck, it is necessary to install a filter if necessary.
(2) The installation of flow meters should avoid vibration, magnetic fields, and thermal radiation.
(3) The changes in density and viscosity of the medium have an impact on the flow indication and should be corrected if necessary.
Technical parameters:
Instrument caliber: Threaded connection: 4, 6, 10, 15, 20, 25, 32, 40
Flange connection: (15、20、25、32、40)50、65、80、100、125、150、200
Insertion type: over 200
Range ratio: 1:10; 1:15; 1:20
Instrument material: 304 stainless steel, 316 (L) stainless steel, etc
Medium temperature:- 20℃~ 120℃
Environmental temperature:- 10℃~ 55℃
Relative humidity: 5%~9%
Atmospheric pressure: 86~106Kpa
Output signal: Sensor: Pulse frequency signal, low level ≤ 0.8V, high level ≥ 8V
Transmitter: two-wire 4-20mA current signal or 1-5V voltage signal
Power supply: Sensor: 12VDC 24VDC (optional)
Transmitter: 24VDC
On site display type: The instrument comes with a built-in lithium battery
Explosion proof form: Basic type non explosion proof, explosion-proof type
Protection level: IP65、IP67