KD-808CMulti parameter water quality tester
KD-808DMulti parameter water quality tester
1Product Features:
1]Can detect the concentration, absorbance, and transmittance of nearly a hundred parameters in water quality, andCan store, print, query, and upload concentration values to a computer.
2】Measurement wavelength can be selected.
3】In addition to the factory curve, usersYou can add curves and calibrate curves by yourselfAnd store it in the instrument.
4】Instrument measurement methodOptional line method or line methodChoosing the line method can achieve more accurate measurement of some parameters with poor linearity.
5】Equipped with one click recovery functionWhen the factory curve and user curve data records are lost due to accidents, one click recovery can be achieved.
6】The instrument can record user calibrated curves and dataTake backup measuresWhen unexpected loss occurs, recovery operations can be carried out.
7】The instrument comes with various safety measures,Can set startup and system settings, input password.
8】InstrumentComes with calibration functionSelf calibration during operation can effectively eliminate drift errors caused by long-term use.
9】The instrument adopts5Large screen color touch screen operationThe user interface is user-friendly.
10】Adjustable light intensity, divided into16level,Any setting,It can effectively solve the problem of measurement range expansion caused by the strength of signals.
11】Can query curvesIn addition to querying the curve equation, the standard value and corresponding absorbance of each standard substance during calibration can also be queried
The degree, calibration time, and calibration personnel number fully reproduce the state during calibration.
12】When recording queries,Can perform single item printing or page printing.
13】SystemHaving bilingual functionCan switch between Chinese and English.
14】CType storable curve300Article,DType is3500strip;CType: Number of storable records1000Article,DType is100000strip.
15】Optimization and upgrade of optical system(DType), measurement system、Better accuracy and stability.
16】ContainingCOD(Chromium method), total phosphorus, total nitrogenTotal chromiumThe parameters are equipped with a digestion instrument, and the digestion instrument data can be found inXJY-16Bparameter.
IItechnical parameter
1. You can choose customizationMeasurement parameters:CODAmmonia nitrogen, total phosphorus, total nitrogen, copper, iron, nickel, hexavalent chromium, phosphate, nitrite, etc70Multiple parameters
2. Reading mode: concentration, absorbance, transmittance
3. Maximum absorbance error:0.005A
4. Absorption range:-2.000~2.000
5. Wavelength:420nm、440nm、470nm、520nm、540nm、560nm、610nm、630nm、660nm、680nm、700nm
Customize any wavelength within the above range to choose from
6. Repeatability:≤3%
7. Optical stability: The absorbance value of the instrument is within20minInternal drift less than0.002A
8. Weight:5kg
9. Dimensions: Host:400×310×158mm
IIIMeasurement range:
Serial number |
Measurement project |
Measurement range |
Company |
Accuracy(+/-) |
1 |
COD(Chromium method Low range) |
5-200 |
mg/L |
5% |
2 |
COD(Chromium method Medium range) |
200-1000 |
mg/L |
5% |
3 |
COD(Chromium method High range) |
1000-2000 |
mg/L |
5% |
4 |
Ammonia nitrogen(Low range) |
0.02-5.00 |
mg/L |
3%(F.S) |
5 |
Ammonia nitrogen(High range) |
5.00-25.00 |
mg/L |
3%(F.S) |
6 |
Total phosphorus(Low range) |
0.02-2.00 |
mg/L |
5%(F.S) |
7 |
Total phosphorus(High range) |
2.00-10.00 |
mg/L |
5%(F.S) |
8 |
Total nitrogen(Low range) |
0.10-15 |
mg/L |
5%(F.S) |
9 |
Total nitrogen(High range) |
15-150 |
mg/L |
5%(F.S) |
10 |
CODMn(Permanganate index) |
0.00-10.00 |
mg/L |
0.2or5% |
11 |
Residual chlorine (low range) |
0.02-2.00 |
mg/L |
0.1or5% |
12 |
Residual chlorine (high range) |
2.00-10.00 |
mg/L |
5% |
13 |
Total chlorine (low range) |
0.02-2.00 |
mg/L |
0.1or5% |
14 |
Total chlorine (high range) |
2.00-10.00 |
mg/L |
5% |
15 |
Chlorine dioxide (low range) |
0.05-2.00 |
mg/L |
0.2or5% |
16 |
Chlorine dioxide (high range) |
2.00-20.00 |
mg/L |
5% |
17 |
sulfate |
5-200 |
mg/L |
5% |
18 |
Nitrate (nitrogen) |
0.02-10.0 |
mg/L |
0.1or5% |
19 |
Phosphate (low range) |
0.01-10.0 |
mg/L |
0.2or5% |
20 |
Phosphate (high range) |
10.0-50.0 |
mg/L |
5% |
21 |
Nitrite nitrogen (low) |
0.02-1.0 |
mg/L |
0.05or5% |
22 |
Nitrite nitrogen (high) |
1.0-5.0 |
mg/L |
5% |
23 |
sulfide |
0.005-1.000 |
mg/L |
5%(F.S) |
24 |
fluoride |
0.05-2.0 |
mg/L |
5%(F.S) |
25 |
cyanide |
0.01-0.50 |
mg/L |
5%(F.S) |
26 |
Bromide compound |
0.10-5.00 |
mg/L |
5%(F.S) |
27 |
formaldehyde |
0.05-2.5 |
mg/L |
5%(F.S) |
28 |
Volatile phenol(low) |
0.20-5.0 |
mg/L |
5%(F.S) |
29 |
Volatile phenols (high) |
5.0-10.0 |
mg/L |
5%(F.S) |
30 |
Hydrazine |
0.01-0.50 |
mg/L |
5%(F.S) |
31 |
Aniline compounds(low) |
0.03-1.0 |
mg/L |
5%(F.S) |
32 |
Aniline compounds (high) |
1.0-5.0 |
mg/L |
5%(F.S) |
33 |
silicon dioxide |
0.01-5.00 |
mg/L |
5%(F.S) |
34 |
Total alkalinity(low) |
0-100 |
mg/L |
5%(F.S) |
35 |
Total alkalinity (high) |
100-1000 |
mg/L |
5%(F.S) |
36 |
Total hardness(low) |
0.1-5.0 |
mg/L |
5%(F.S) |
37 |
Total hardness (high) |
5.0-200.0 |
mg/L |
5%(F.S) |
38 |
Chloride ion (chloride) |
0.20-100.0 |
mg/L |
5%(F.S) |
39 |
copper(low) |
0.02-1.0 |
mg/L |
5%(F.S) |
40 |
Copper (high) |
1.0-10.0 |
mg/L |
5%(F.S) |
41 |
zinc |
0.2-5.0 |
mg/L |
5%(F.S) |
42 |
nickel(low) |
0.02-0.50 |
mg/L |
5%(F.S) |
Serial number |
Measurement project |
Measurement range |
Company |
Accuracy(+/-) |
43 |
Nickel (high) |
0.50-1.00 |
mg/L |
5%(F.S) |
44 |
nickel |
0.02-10.0 |
mg/L |
5%(F.S) |
45 |
iron(low) |
0.0-5.0 |
mg/L |
5%(F.S) |
46 |
Iron (High) |
5.0-10.0 |
mg/L |
5%(F.S) |
47 |
Hexavalent chromium |
0.01-1.00 |
mg/L |
5%(F.S) |
48 |
cadmium |
0.05-0.50 |
mg/L |
5%(F.S) |
49 |
manganese(low) |
0.01-0.10 |
mg/L |
5%(F.S) |
50 |
Manganese (high) |
0.10-1.0 |
mg/L |
5%(F.S) |
51 |
manganese |
0.02-5.00 |
mg/L |
5%(F.S) |
52 |
Total chromium |
0.02-1.0 |
mg/L |
5%(F.S) |
53 |
aluminium(low) |
0.01-0.40 |
mg/L |
5%(F.S) |
54 |
Aluminum (high) |
0.40-4.00 |
mg/L |
5%(F.S) |
55 |
silver |
0.01-1.00 |
mg/L |
5%(F.S) |
56 |
molybdenum |
0.05-1.00 |
mg/L |
5%(F.S) |
57 |
arsenic(low) |
0.004-0.100 |
mg/L |
5%(F.S) |
58 |
Arsenic (high) |
0.100-0.500 |
mg/L |
5%(F.S) |
59 |
beryllium |
0.001-0.10 |
mg/L |
5%(F.S) |
60 |
boron |
0.10-2.00 |
mg/L |
5%(F.S) |
61 |
mercury |
0.002-0.50 |
mg/L |
5%(F.S) |
62 |
lead |
0.01-0.50 |
mg/L |
5%(F.S) |
63 |
chroma(Low range) |
1.0-50.0 |
PCU |
3%(F.S) |
64 |
chroma(High range) |
50-500 |
PCU |
3%(F.S) |
65 |
turbidity |
0-400(Three ranges) |
NTU |
≤2%(F.S) |
66 |
Suspended solids |
0-1000(Two measuring ranges) |
mg/L |
≤2%(F.S) |
67 |
PH(Colorimetric method) |
5.00-8.00 |
PH |
0.1±0.1 |
68 |
Dissolved oxygen (colorimetric method) |
0.1-10.0 |
mg/L |
0.1±5% |
69 |
ozone |
0.01-2.5 |
mg/L |
5%(F.S) |
70 |
Anionic surfactant |
0.01-1.0 |
mg/L |
5%(F.S) |
71 |
Effective chlorine |
0.0-100.0 |
mg/L |
5%(F.S) |
72 |
Chlorite salt |
0.00-20.00 |
mg/L |
5%(F.S) |
73 |
antimony |
0.05-10.0 |
mg/L |
5%(F.S) |
74 |
Iodide |
0.02-1.00 |
mg/L |
5%(F.S) |
78 |
barium |
0.00-5.00 |
mg/L |
5%(F.S) |
4Product configurationSet updetailed list:
host1Common parameters for table and reagent preparation10Several sets, colorimetric tubes, and colorimetric dishes2Only (turbidity, chromaticity, suspended solids),USBLine1Root,
Data collection installation CD1One, charging power supply1One, user manual1Copy, Product Qualification Certificate1Copy and warranty card1Share.
Shenzhen Science Popularization Instrument Experimental Instrument Co., Ltd
website:http://www.kpy2015.com/ contact number:13923840557