KAP55 single flange pressure transmitter
The principle and structure used to measure the pressure of a medium can also be converted into changes in liquid level height. The use of fully seale
Product details

Principle, structure

The pressure used to measure the medium can also be converted into changes in liquid level height. The use of fully sealed capacitive sensitive components ensures excellent stability and reliability for pressure or liquid level measurement. The product can be optionally configured with the HART communication protocol, which can communicate with the control system or handheld device for setting, monitoring, testing, and configuration.

单法兰式压力变送器

characteristic

High precision, high reliability, high stability

Zero point and range can be adjusted on-site

Long lifespan, suitable for continuous liquid level monitoring

4-20mA standard configuration with HART communication protocol

Remote diaphragm sealing device is optional

According to the selection of different membrane materials, various corrosive media can be measured

Explosion proof type optional

Adjustable damping

application

Suitable for liquid level monitoring and pipeline pressure monitoring of medium and large tanks

Mainly used in wastewater/water treatment, shipbuilding, generator equipment, petrochemicals, and food

Industries such as electronics, dyeing and finishing, chemistry, rubber and plastics, hydraulic machinery, chemical pharmaceuticals, etc

Technical Parameter

Range: Refer to the selection table
Output: Two wire 4-20mA DC signal or HART digital signal
Accuracy: 0.1 level, 0.25 level, 0.5 level optional
Stability: ≤±0.45%/55℃
Installation location impact: When the sensor diaphragm is not vertical, it may produce a maximum of
The zero position system error of 0.24Kpa can be corrected by zero adjustment
Vibration impact: ± 0.1% maximum range limit
Power supply impact: Less than the output range of 0.0055/V
Power supply: 12…30VDC
Overload pressure: 1.5 times the range
Load: The maximum load resistance of the circuit board R: R=(V-10.5)/0-236, where
R is the maximum load resistance Ω; V power supply voltage (see left figure)
Start time: 5Sec
Refresh time: 0.25Sec
Range and zero adjustment: Adjust through buttons or using a HART communicator
Positive and negative migration: The maximum positive migration amount is the upper limit of the measurement range (URL) and the measurement
The maximum negative transfer of the range difference is URL
Error Alert: The self diagnostic program detects a fault, and the simulated output is higher than 20.8mA or
Alarm below 3.8mA, high/low flag adjusted through HART communicator
Working temperature: Electronic circuit: -30... 85 ℃, sensitive components (filled with silicone oil):
-40…104℃; (Filled with inert oil): -0... 70 ℃
Medium temperature: -40... 104 ℃ (limit)
Storage temperature: -40…125℃
Relative humidity: 5%-98%
Protection level: IP65
Structural materials: The electrical casing is made of aluminum alloy, and the materials for other parts are detailed in the selection table
Pressure connection: The connection hole on the pressure chamber is 1/4-18NPT, and the connection on the pressure joint
The hole is 1/2-14NPT
Electrical connection: M20 × 1.5 screw hole for connecting cable conduit
Weight: About 3.9kg (excluding accessories)

Load characteristic diagram


负载特性图

Wiring diagram


接线图
stitch cable color Function/4-20mA output
1 brown 24VDC power supply (± 20%)
2 white 4-20mA output positive pole

dimension


尺寸图


尺寸图


尺寸图

Outline dimension diagram

Flange size bolt hole
size Voltage resistance level outside diameter thickness Insert outer diameter seal number diameter Distribution diameter
mm Mpa D A B C n d D1
DN80 2.0 200 30 76 127 4 19 152
DN100 2.0 235 30 89 157 8 19 190

Matching flange size diagram


DN80配对法兰示意图

Schematic diagram of DN80 paired flange


DN100配对法兰示意图

Schematic diagram of DN100 paired flange

Flange type liquid level dimension diagram

Flange size bolt hole
size Voltage resistance level outside diameter thickness Insert outer diameter seal number diameter Distribution diameter
mm Mpa D A B C n d D1
DN80 2.0 200 30 76 127 4 19 152
DN100 2.0 235 30 89 157 8 19 190
Flange gasket size table
Companion flange D d
DN80 127 80
DN100 157 100
The sealing gasket can be made of materials such as nitrile rubber and polytetrafluoroethylene depending on the medium


法兰液压尺寸图

Model Selection Table

KAP55- Single flange pressure transmitter
Range of measurement
0…1.3Kpa~7.5KPA 0…40~200Kpa
0…4~40Kpa 0…0.16~1000Kpa
output
4…20mA
hart protocol
accuracy
0.1 level
0.25 level
Level 0.5
specifications
mounting flange insertion length High voltage side isolation diaphragm material
DN80 0mm Stainless steel 1.4435 (316L)
DN80 50 Stainless steel 1.4435 (316L)
DN80 100 Stainless steel 1.4435 (316L)
DN80 150 Stainless steel 1.4435 (316L)
DN80 0mm Hastelloy C
DN80 50 Hastelloy C
DN80 100 Hastelloy C
DN80 150 Hastelloy C
DN80 0mm tantalum
DN100 0mm Stainless steel 1.4435 (316L)
DN100 50 Stainless steel 1.4435 (316L)
DN100 100 Stainless steel 1.4435 (316L)
DN100 150 Stainless steel 1.4435 (316L)
DN100 0mm Hastelloy C
DN100 50 Hastelloy C
DN100 100 Hastelloy C
DN100 150 Hastelloy C
DN100 0mm tantalum
Body liquid receiving material
Flange joint Exhaust/Drain Valve Isolation Diaphragm
Stainless steel 1.4435 (316L) Stainless steel 1.4435 (316L) Stainless steel 1.4435 (316L)
Stainless steel 1.4435 (316L) Stainless steel 1.4435 (316L) Hastelloy C
Stainless steel 1.4435 (316L) Stainless steel 1.4435 (316L) Monel
Stainless steel 1.4435 (316L) Stainless steel 1.4435 (316L) tantalum
Hastelloy C Hastelloy C Hastelloy C
Hastelloy C Hastelloy C tantalum
(Special alternative) VARIO
1/2NPT taper pipe threaded joint (standard) The side relief valve is located at the upper part of the pressure chamber
M20 * 1.5 threaded joint The side relief valve is located at the lower part of the pressure chamber
LCD display function Agreed explosion-proof function
0~100% linear indicator (pointer type)
The selection form for appeal does not include selection codes. If you need a code, please contact us or fill in your information
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!