K. Application of DK mine energy-saving fan:
This series of fans is specifically designed to meet the needs of various non coal mines such as metallurgy, non-ferrous metals, gold, chemical, building materials, and nuclear industries. They can be used as main and auxiliary fans, and can be installed on the surface or underground. They are suitable for multi fan joint operation and are ideal fans for various levels of fan stations in multi fan series parallel multi-stage ventilation systems. They are also suitable for ventilation and air exchange in large workshops, tunnels, civil defense projects, and other occasions.
Main structural characteristics of the fan:
1. Adopting twisted wing shaped blades, the aerodynamic efficiency is high and the energy-saving effect is extremely significant.
2. Diverse performance and complete specifications, it can be well matched with ventilation networks of various resistance and air volume types, and can maintain long-term efficient operation.
3. Equipped with a stabilizing ring device, the characteristic curve has no hump, no surge danger, and can operate safely and stably under any resistance state, suitable for multi fan joint operation.
4. The structure adopts a direct connection between the electric motor and the impeller, with good overall stability, easy installation, easy maintenance, and low local resistance of the device.
5. Compact structure and good moisture resistance. The main body of the fan adopts a welded structure of steel plate and section steel, and the blades are made of steel plate material, hollow. The blades and the whole machine have high strength and strong resistance to underground blasting shock waves. They can be installed on the surface and are also suitable for installation underground, especially as fan stations for multi-stage ventilation systems.
6. Reversible reverse wind, with a reverse wind rate greater than 60%, does not require the construction of a reverse air duct.
7. The installation angle of the blades can be adjusted, and the fan condition can be adjusted at any time according to the changes in mine production.
8. The amount of civil engineering work is very small, which can save a lot of investment.
9. Low noise
This product consists of mining energy-saving fans such as DK40, DK45, K40, K45, etc. The K40 and K45 series auxiliary fans adopt the simplest transmission structure of direct connection between the motor and the impeller, consisting of components such as the collector, main body, and diffuser. Adopting a new type of high-efficiency wing shaped twisted blade, with adjustable installation angle, and installing a stabilizing ring device to ensure that the aerodynamic performance curve has no hump, the base can be equipped with axially movable wheels. Therefore, it has the advantages of high efficiency, low noise, wide coverage, stable performance, simple structure, easy installation, and convenient use. The DK40 and DK45 series main fans are connected by two K40 and K45 fans of the same model and power, and the two-stage impellers rotate in opposite directions to form a counter rotating structure. Compared with the long axis transmission type main fan, they have the advantages of high operating efficiency, low operating resistance, and saving civil engineering investment, and have significant energy-saving effects.
K. DK series mine energy-saving fan performance:
(1) Serial number: No. 7 to No. 26;
(2) Series speed: 1450, 980, 730 r/min;
(3) Airflow range: 2.0~164.2m3/s;
(4) Full pressure range: 38-3819pa;
(5) Power range: 1.1-500kW;
(6) Fan efficiency: K-type single-stage total pressure efficiency η=94%, DK type counter rotating static pressure efficiency η=86%;
(7) Operating noise: LA≤85dB(A)。
K. DK mine energy-saving fan parameters:

 Performance parameter table of K40 mining energy-saving ventilation fan:
Machine number
Speed r/min
Airflow m ³/s
Total pressure Pa
Power (kW)
7
980
2.0~4.3
38~174
1.1
8
1450
4.4~9.5
108~497
5.5
980
3.0~6.4
49~227
2.2
9
1450
6.2~13.5
136~629
11
980
4.2~9.1
62~287
3
10
1450
8.5~18.6
168~776
15
980
5.8~12.5
77~355
5.5
11
1450
11.3~24.7
203~9390
30
980
7.7~16.7
93~429
7.5
730
5.7~12.4
52~238
4
12
1450
14.7~32.1
242~1118
37
980
9.9~21.7
111~510
15
730
7.4~16.1
61~283
5.5
13
1450
18.7~40.8
284~1312
55
980
12.6~27.5
130~599
18.5
730
9.4~20.5
72~332
7.5
14
1450
23.4~50.9
329~1521
90
980
15.8~34.4
150~695
30
730
11.8~25.6
84~386
11
15
1450
28.7~62.6
378~1746
110
980
19.4~42.3
173~798
37
730
14.5~31.5
96~443
15
16
980
23.6~51.4
197~908
55
730
17.6~38.3
109~504
22
17
980
28.3~61.6
222~908
75
730
21.1~45.9
123~568
30
18
980
33.6~73.1
249~1149
90
730
25.0~54.5
138~637
37
19
980
39.5~86.0
277~1280
110
730
29.4~64.1
154~710
55
20
980
46.0~100.3
307~1418
160
730
34.3~74.7
170~787
75
21
980
53.3~116.1
339~1563
200
730
39.7~86.5
188~867
90
22
980
61.3~113.4
372~1716
250
730
45.7~99.4
206~952
110
23
730
52.2~113.6
225~1041
132
24
730
59.3~129.1
245~1133
160
25
730
67.0~146
266~1229
200
26
730
75.4~164.2
288~1330
250


Performance parameter table of K45 mining energy-saving ventilation fan:

Machine number
Speed r/min
Airflow m ³/s
Total pressure Pa
Power (kW)
7
980
3.0~5.7
125~240
1.5
8
1450
6.6~12.5
357~685
7.5
980
4.5~8.4
163~313
3
9
1450
9.5~17.8
452~867
15
980
6.4~12.0
207~396
5.5
10
1450
13.0~24.0
558~1071
30
980
8.7~16.5
255~489
7.5
11
1450
17.3~32.6
675~1295
45
980
11.6~22.0
309~592
15
12
1450
22.5~42.3
804~1542
75
980
15.1~28.5
367~704
18.5
13
1450
28.6~53.8
943~1810
90
980
19.2~36.3
431~827
30
14
1450
35.7~67.2
1094~2099
132
980
23.9~45.3
500~959
45
15
1450
43.9~82.6
1256~2409
200
980
29.4~55.7
574~1101
55
16
980
35.7~67.6
653~1252
90
17
980
42.8~81.1
737~1414
110
18
980
50.9~96.2
826~1585
160
19
980
59.8~113.2
920~1766
200
20
980
69.8~132.0
1019~1956
250


Performance parameter table of DK40 mining energy-saving ventilation fan:

Machine number
Speed r/min
Air volume/s
Total pressure Pa
Power (kW)
15
980
18.2~43.6
382~1690
2×37
16
980
22.1~52.9
435~1923
2×55
17
980
26.5~63.5
491~2171
2×75
18
980
31.5~75.4
551~2433
2×90
730
23.5~56.1
306~1350
2×37
19
980
37.0~88.6
614~2711
2×132
730
27.6~66.0
341~1504
2×55
20
980
43.2~103.4
680~3004
2×160
730
32.2~77.0
377~3334
2×75
21
980
50.0~119.7
750~3312
2×200
730
37.3~89.1
416~1838
2×90
22
730
42.8~102.5
457~2017
2×110
23
730
48.9~117.1
499~2204
2×132
24
730
55.6~133.0
543~2400
2×160
25
730
62.9~150.4
589~2605
2×200


Performance parameter table of DK45 mining energy-saving ventilation fan

Machine number
Speed r/min
Airflow m ³/s
Total pressure Pa
Power (kW)
12
980
10.7~27.6
698~1374
2×22
13
980
13.6~35.0
819~1613
2×37
14
980
17.0~43.8
950~1871
2×55
15
980
20.9~53.8
1091~2148
2×75
16
980
25.4~65.3
1241~2444
2×90
730
18.9~48.7
688~1356
2×37
17
980
30.4~78.3
1400~2759
2×132
730
22.7~58.4
777~1531
2×55
18
980
36.1~93.5
1570~3093
2×160
730
26.9~69.3
871~1716
2×75
19
980
42.5~109.4
1750~3446
2×200
730
31.6~81.5
971~1912
2×90
20
980
49.5~127.6
1939~3819
2×250
730
36.9~95.1
1076~2119
2×110
21
730
42.7~110.1
1186~2336
2×160
22
730
49.1~126.6
1302~2563
2×200


Attention: Please confirm and indicate the fan number, air volume, speed, pressure, outlet angle, rotation direction, and motor model specifications when placing an order. If there are special requirements, please specify them.
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!