JZ系列节能电磁铁鼓式制动器
The installation dimensions and braking torque parameters of the brake comply with:JB/ZQ4388-1997 standard, technical requirements comply with JB/T7685-2006 standard.
Key Features:Safe and reliable use; High frequency of action, energy-saving; Green and environmentally friendly, asbestos free lining.
Usage conditions:
Environmental temperature: -25 ℃ -40 ℃
AC 380V/50Hz power supply.
The altitude of the usage location shall not exceed 2000m.
The relative humidity of the air in the usage location should not exceed 90%.
There shall be no flammable, explosive, corrosive or insulating gases or conductive dust around the brake.
Outdoor rain and snow erosion or corrosive gases and media should use anti-corrosion products.
Product Details

Model Meaning

Technical Specifications
Unit: (mm)
Note: No further notice will be given for changes in the use of electromagnets. Large sized electromagnets are equipped with larger electrical control boxes and need to be placed separately.
Outline dimension table
Unit: (mm)
model |
A |
b |
D |
d |
E |
F |
G |
H |
h1 |
i |
K |
M |
P |
n |
G1 |
JZ-100 |
230 |
70 |
100 |
13 |
165 |
75 |
125 |
300 |
100 |
40 |
110 |
145 |
132 |
6 |
45 |
JZ-200 |
290 |
80 |
200 |
17 |
215 |
100 |
208 |
435 |
170 |
60 |
175 190 |
126 |
132 |
8 |
108 |
JZ-300 |
385 |
140 |
300 |
22 |
295 |
130 |
290 |
600 |
240 |
80 |
250 270 |
160 |
167 |
10 |
140 |
JZ-400 |
505 |
180 |
400 |
22 |
350 |
180 |
350 |
782 |
320 |
130 |
325 |
210 |
243 |
12 |
190 |
JZ-500 |
577 |
200 |
500 |
22 |
490 |
200 |
405 |
950 |
400 |
150 |
380 |
250 |
243 |
16 |
225 |
JZ-600 |
675 |
240 |
600 |
26 |
560 |
220 |
500 |
1160 |
475 |
170 |
475 |
305 |
271 |
18 |
250 |
Note: Specific models, structures, and external dimensions are subject to change.