Product IntroductionProduct Introduction
The JFD-2000A partial discharge detection system is the main test item for insulation of power equipment, and parameters such as partial discharge are important indicators for evaluating the quality of power equipment. The JFD-2000A partial discharge detection system, developed based on current international and domestic technological advancements, is a new generation member of the successful HTJF series partial discharge instrument. In addition to inheriting the advantages of the previous generation product, this product also has functions such as full process control, automatic calibration, automatic synchronization, automatic voltage recording, automatic measurement, storage and playback. It can measure various partial discharge parameters specified by IEC-270, such as discharge repetition rate n, average discharge current I, square rate D, etc. It adopts multiple view display modes such as sine and dot matrix, new digital filtering and interference suppression functions, combined with rich dynamic statistical analysis graphs, making on-site interference more effectively suppressed, and user operation and diagnosis more convenient and comfortable. With the continuous development of software, its functions continue to expand, such as pulse polarity discrimination and partial discharge measurement in balanced circuit mode.
The JFD-2000A partial discharge detection system fully complies with the new GB7354 and IEC-270 "Partial Discharge Measurement" standards in terms of its detection method, measurement circuit, and technical performance parameters. Suitable for partial discharge measurement of various high-voltage electrical equipment, covering full voltage and capacity levels, representing the advanced technology of digital partial discharge instruments in China.
Product nickname: Partial Discharge Tester, Partial Discharge Tester, Partial Discharge Tester, Partial Discharge Testing System
Product parametersProduct Parameters
Scanning method: (The instrument has a dual measurement system of linear sweep frequency measurement and segmented sweep frequency measurement)
measurement channel | A. Channel B 2 (capable of simultaneously collecting discharge signals) |
detection sensitivity | 0.1pC |
Measurement frequency band | 3dB bandwidth 10kHz~300kHz |
Programmable filter setting gear | Low end: 10, 20, 40kHz |
High end: 100, 200, 300 kHz | |
Gain dynamic range | 120dB |
Sampling rate | 0.1 μ s/point per channel |
Sampling precision | 8-bit ± 1/2LSB |
Test voltage frequency | 3010015020250Hz or any Hz |
Calibrate pulse generator | HTJF-301 |
Calibrate pulse voltage | 10V, 5V, 2V, 1V, 0.5V, 0.2V, six adjustable levels |
Calibration capacitor | 50pF, 200pF adjustable in two levels |
Calibrate the rise time of pulse voltage | < 60ns, pulse width > 20 μ s |
Calibrate the pulse voltage drop time | >100μs |
Adjustable range of calibration pulse phase angle | 0-360 degrees |
Partial discharge peak display | 0~10000pC |
Component packaging method | Long term usable packaging |
Working power supply | AC 220V ± 10%, 50Hz, power<100VA, insurance 0.5A |
1. The appearance of the product is subject to the actual product. Technical parameters and models are subject to change without prior notice. If there is any act of theft or copying, legal responsibility will be pursued.
2. To learn more about Huatian products, please enter the product center. Service Hotline: 400-8855-448
Product FeaturesProduct Characteristics
-
1. Partial discharge detection system pure programmable working mode
-
2. Full Chinese character menu prompt
-
3. Automatic calibration, automatic synchronization, automatic voltage recording, automatic measurement, saving and playback
-
4. Automatically generate test reports
-
5. Display of 2D and 3D partial discharge spectra
-
6. Adopting digital window opening technology, with strong anti-interference ability
-
7. Dual channel measurement and digital differential technology can simultaneously measure partial discharge signals of two samples or two measurement points of one sample, making it easy to analyze the source of partial discharge signals


Product AtlasProduct Picture
Product Attachment Diagram

host

Calibration pulse generator

input unit

High frequency power cord

Partial discharge measurement signal line (8m)

Partial discharge measurement signal line (8m)

Red black signal line

Partial discharge signal filtering adapter

mouse

fuse

power line

Instruction manual, inspection report, certificate of conformity
Product detail diagram

host

Right side of the host

Front panel

screen

USB interface

Digital display screen

power switch

Keyboard control area

Rear side of the host

Back of the host

Power cord socket

Data cable interface

Test line interface

Heat dissipation port
product certificateProduct Certificate
Our company's products are strictly produced in accordance with international and national standards and industry regulations. They have passed the testing of national, provincial, and municipal power research institutes, measurement centers, and authoritative power departments, and have fully passed the ISO9001 international quality management system certification, the People's Republic of China manufacturing measuring instrument license, GB/T19001-2016 quality management system requirements, GB/T24001-2016 environmental management system requirements, and GB/T45001-2020 occupational health and safety management system requirements.