Shenzhen York Technology Co., Ltd
Home>Products>Intrinsic safety calibrator MC2-IS
Intrinsic safety calibrator MC2-IS
Product Name: Intrinsic Safety Verification Instrument Product Model: MC2-IS product exhibitor: Shenzhen York Technology Co., Ltd
Product details

Characteristic performance of MC2 and MC2-IS:

Accuracy guarantee
Beamex ® MC2 and Beamex ® MC2-IS is a highly accurate process calibrator, and each MC2 and MC2-IS calibrator comes with a traceable quality calibration certificate.
Compact and compact structure, user-friendly interface
MC2 and MC2-IS calibrators are both compact in structure, small in size, lightweight, and easy to carry; Large graphic display screen and multilingual interface; Full numeric keypad. It can be quickly and easily learned to use.
Durable and sturdy on-site verification device
MC2 and MC2-IS are sturdy and durable, suitable for on-site use. Equipped with collision protection, the diaphragm keyboard makes the device more suitable for the on-site environment and weather resistant.
Wide range configuration structure
MC2 and MC2-IS offer many configurations, such as internal and external pressure modules. For example, MC2-IS can connect approximately 20 types of Beamex intrinsic safety pressure modules externally.
idiot proofMC2-IS
The usage environment of MC2 and MC2-IS:
Beamex ® MC2:Used for on-site verification in ordinary environments
Beamex ® MC2 includes three different handheld verification functions, applied in different fields: MC2 pressure/electrical signal verification function, MC2 temperature/electrical signal verification function, and MC2 multifunctional verification. MC2 has a compact structure, small size, and is easy to use. It has a large graphical display screen, main menu interface, and full numeric keypad. As a calibration instrument from Beamex, MC2 represents extremely high quality standards
Beamex ® MC2-IS:Used for verification in hazardous environments
Beamex ® The MC2-IS intrinsic safety multifunctional calibrator is certified by ATEX (European Explosion proof Directive) and IECEx (International Electrotechnical Commission Explosion proof Electrical Product Certification System). Specially designed for environments with potential explosion, such as offshore platforms, oil refineries, chemical and petrochemical plants, where flammable gases are present. This device can be connected to approximately 20 types of Beamex intrinsic safety pressure modules externally. Compact structure and small size.
MC2 and MC2-IS belong to the same series of calibrators with four different functions

MC2main features
The product has three types:
MC2 pressure/electrical signal calibrator
MC2 temperature/electrical signal calibrator
MC2 multifunctional calibrator
Internal/external pressure module
ATEX and IECEx certified intrinsic safety multifunctional process calibrators
Approximately 20 types of Beamex intrinsic safety pressure modules can be connected externally
• Compact structure and small size
• User friendly interface
MC2Comparison of Series Functions
function
MC2-PE
pressure/electrical signal
Calibrator
MC2-TE
temperature/electrical signal
Calibrator
MC2-MF
Multi functional calibrator
MC2-IS
Intrinsic safety calibrator
Built in pressure module
-
(Only applicable to atmospheric pressure)
External pressure module interface
Current measurement(Equipped with internal and external power supply)
Voltage measurement
frequency measurement
Pulse counting
Switching measurement
built-inHART ®compatible24 VDCCircuit power supply
(1
Current generation(Equipped with internal and external power supply)
-
(2
Voltage generation
-
Frequency generation
-
Pulse generation
-
mVmeasure/simulation
-
Resistance measurement/simulation
-
Thermal resistanceRTDmeasure/simulation
-
ThermocoupleTCmeasure/simulation
-

Standard configuration:
1.User Guide
2.Verification certificate
3.NiMHRechargeable batteries and chargers
4.A pair of test wires and clamps
5.USBCable
6.Pressure connection(G1/8” female to G 1/8”male 60Cone surface)
7.Product safety information andECelectromagnetic compatibility(MC2-IS)
Optional Accessories
1. Pressure hose
2. Carrying bag(soft)
3. Connection cable for external pressure module
4. Dry battery cylinder
5. Verify the hand pump

General technical parameters (applicable to all models):
features
explain
display
60 mm×60mm; 160 × 160 pixels, LCD display with backlight
weight
770g
size
215mm×102mm×49mm(D/W/H)
keyboard
Thin film keyboard
Battery type
Rechargeable NiMH, 4000mAh, 3.6V DC
Charging time
5 hours
Charging power supply
100~240VAC,50~60Hz
Battery settings
13-24-hour measurement mode, background light off;
The 8-12 hour mode provides a 12mA circuit power supply with the background light on.
Optional 4 alkaline battery settings
8-hour measurement mode, background light off;
4-hour measurement mode provides 12mA circuit power supply, with background light on
working temperature
-10~50℃(14~122℉)
Working temperature during charging
0~35℃(32~95℉)
Storage temperature
-20~60℃(-4~140℉)
humidity
0 to 80% non condensing
Preheating time
Effective after 5 minutes of preheating
Maximum input voltage
30V DC,60V DC
safety standards
Derective 73/23/EEC,EN61010-1
EMC
Derective 89/336/EEC,EN61010-1

Voltage measurement(-160V DC)
range
resolving power
1-year uncertainty
±0.25V
0.001mV
0.02%RDG+5µV
±(0.25~1V)
0.01mV
0.02%RDG+5µV
1~25V
0.1mV
0.02%RDG+0.25mV
25~60V
1mV
0.02%RDG+0.25mV

characteristic
parameter
temperature coefficient
<±0.0015%RDG/℃ outside of 18~28℃
<±0.0008RDG/℉ outside of 64.4~82.4℉
Input impedance
>1Mohm
selectable unit
V, mV, µV
Display refresh rate
3/second







characteristic
parameter
temperature coefficient
<±0.0015%RDG/℃ outside of 18~28℃
<±0.0008RDG/℉ outside of 64.4~82.4℉
Input impedance
<7.5ohm
selectable unit
mA, µA
Display refresh rate
3/second

Circuit power supply

characteristic
parameter
Output current
Maximum 25mA, short circuit protection
output voltage
24V±10%
Output impedance in HART compatible mode
300ohm±20%

range
resolving power
1-year uncertainty
±25mA
0.0001mA
0.02%RDG+1.5µA
±(25~100mA)
0.001mA
0.02%RDG+1.5µA

Electrical signal measurement
frequency measurement(0.002750,000Hz)

range
resolving power
1-year uncertainty
0.0027~0.5Hz
0.000001 Hz
0.01%RDG
0.5~5 Hz
0.00001 Hz
0.01%RDG
5~50 Hz
0.0001 Hz
0.01%RDG
50~500 Hz
0.001 Hz
0.01%RDG
500~5000 Hz
0.01 Hz
0.01%RDG
5000~50000 Hz
0.1 Hz
0.01%RDG

characteristic
parameter
temperature coefficient
Specification valid from 10 to 50℃
Input impedance
>1 Mohm
Trigger level
-1~14v in 1v steps and open collector inputs
Minimum signal amplitude
2Vpp(<10kHz),3Vpp(10~50kHz)
selectable unit
Hz,kHz,cph,cpm,1/Hz(s),1/kHz(ms),1/MHz(us)
Switching time
267ms+1signal period

Pulse counting
characteristic
parameter
range
0 ~ 9999999 pulse
Input impedance
>1Mohm
Trigger level
-1~14V in 1V steps and open collector inputs
Minimum signal amplitude
2Vpp(pulse length>50us),3Vpp(pulse length 10..50us)

Switch quantity test
characteristic
parameter
Potential zero point
Test voltage (current)
2.8V (0.13A) or 24V (35A)
Level detection
Input impedance
>1 Mohm
Trigger level
-1~14V in 1V steps

pressure measurement
Internal pressure module(IPM)
Internal module
Company
range
resolving power
1Annual uncertainty
IPM200mC
kPa
mbar
iwc
±20
±200
±80
0.001
0.01
0.01
0.05% RDG + 0.05% FS
IPM2C
kPa
bar
psi
-100 ~ 200
-1 ~ 2
-14.5 ~ 30
0.01
0.0001
0.001
0.05% FS
IPM20C
kPa
bar
psi
-100 ~ 2000
-1 ~ 20
-14.5 ~ 300
0.1
0.001
0.01
0.05% FS
IPM160
MPa
bar
psi
0 ~ 16
0 ~ 160
0 ~ 2400
0.001
0.01
0.1
0.05% FS
Atmospheric pressure module options
If an atmospheric pressure module (with an uncertainty of 0.1 kPa) is selected, the above pressure can be measured in absolute pressure.

characteristic
parameter
temperature coefficient
<±0.001%RDG/℃ outside 15~35℃
<±0.0006%RDG/℉ outside 59~95℉
Maximum overvoltage protection
2 times the range
Pressure interface
G 1/8 "internal thread (ISO 228/1) 60 ° internal cone
Media compatibility
Wet parts: AISI316 stainless steel, nitrile rubber
Pressure unit
Pa、hPa、kP、MPa、mbar、lbf/ft2、kgf/cm2、 kgf/m2、 kgf/m2、 at、mmH2O、cmH2O、mH2O、iwc、ftH2O. MmHg, cmHg, mHg, minHg, mmHg (0 ℃), inHg (0 ℃) mmH2O (4 ℃), inH2O (4 ℃) ftH2O (4 ℃) inH2O (60 ℉) mmH2O (68 ℉) ftH2O (68 ℉) tm、 4 users set units
Display refresh rate
2.5 per second

characteristic
parameter
temperature coefficient
<±0.001%RDG/℃ outside 15~35℃
<±0.0006%RDG/℉ outside 59~95℉
Maximum overvoltage protection
2 times the range
Pressure interface
G 1/8 "internal thread (ISO 228/1) 60 ° internal cone
Media compatibility
Wet parts: AISI316 stainless steel, nitrile rubber
Pressure unit
Pa、hPa、kP、MPa、mbar、lbf/ft2、kgf/cm2、 kgf/m2、 kgf/m2、 at、mmH2O、cmH2O、mH2O、iwc、ftH2O. MmHg, cmHg, mHg, minHg, mmHg (0 ℃), inHg (0 ℃) mmH2O (4 ℃), inH2O (4 ℃) ftH2O (4 ℃) inH2O (60 ℉) mmH2O (68 ℉) ftH2O (68 ℉) tm、 4 users set units
Display refresh rate
2.5 per second

High precision external pressure module(EXT)
External module
amount Cheng
1Annual uncertainty
atmospheric pressure
800~1200 mbar absolute pressure
80~120 kPa absolute pressure, enabling the instrument to have absolute pressure measurement function
0.05 kpa (0.015 inHg)
EXT10mD
± 10 mbar micro differential pressure
± 1 kPa micro differential pressure
0.1% RDG + 0.05% Span
EXT100m
0~100 mbar gauge pressure
0~10kpa gauge pressure
0.04% RDG + 0.025% FS
EXT400mC
±400 mbar
-40kpa ~ 40kpa
0.04% RDG + 0.02% FS
EXT1C
±1 bar
-100kpa ~ 100kpa
0.04% RDG + 0.01% FS
EXT2C
-1 ~ 2 bar
-100kpa ~ 200kpa
0.04% RDG + 0.01% FS
EXT6C
-1 ~ 6 bar
-100kpa ~ 600kpa
0.04% RDG + 0.01% FS
EXT20C
-1 ~ 20 bar
-0.1 ~ 2MPa
0.04% RDG + 0.01% FS
EXT60
0 ~ 60 bar
0 ~ 6MPa
0.04% RDG + 0.01% FS
EXT100
0 ~ 100 bar
0 ~ 10MPa
0.04% RDG + 0.01% FS
EXT160
0 ~ 160 bar
0 ~ 16MPa
0.04% RDG + 0.013% FS
EXT250
0 ~ 250 bar
0 ~ 25MPa
0.04% RDG + 0.015% FS
EXT600
0 ~ 600 bar
0 ~ 60MPa
0.04% RDG + 0.015% FS
EXT1000
0 ~ 1000 bar
0 ~ 100MPa
0.04% RDG + 0.015% FS

Standard precision external pressure module(EXT)
External module
amount Cheng
resolving power
1Annual uncertainty
EXT200mC-s
±200 mbar
-20kpa ~ 20kpa
0.01 mbar
0.05% RDG + 0.05% FS
EXT2C-s
-1 ~ 2 bar
-100kpa ~ 200kpa
0.0001 bar
0.05% FS
EXT20C-s
-1 ~ 20 bar
-0.1 ~ 2MPa
0.001 bar
0.05% FS
EXT160-s
0 ~ 160 bar
0 ~ 16MPa
0.01 bar
0.05% FS

Generation and measurement of electrical signals/simulation
mVmeasure
mVmeasure(T/C -terminal) -25 ~ 150 mV
amount Cheng
resolving power
1Annual uncertainty
-25 ~ 150 mV
0.001 mV
0.02% RDG + 4 µV

features
parameter
temperature coefficient
< ±0.0015% RDG / ℃ outside of 18 ~ 28℃
< ±0.0008% RDG / ℉ outside of 64.4 ~ 82.4℉
Input impedance
>10 Mohm
selectable unit
V, mV, µV
Display refresh rate
3/second

mVproduce
mVproduce(T/C -terminal) -25 ~ 150 mV
range
resolving power
1Annual uncertainty
-25 ~ 150 mV
0.001 mV
0.02% RDG + 4 µV

features
parameter
temperature coefficient
< ±0.0015% RDG / ℃ outside of 18 ~ 28℃
< ±0.0008% RDG / ℉ outside of 64.4 ~ 82.4℉
Maximum load current
5 mA
Load impact
<50 µV/mA
selectable unit
V, mV, µV

Voltage generation
Voltage generation-3 ~ 12 V
range
resolving power
1Annual uncertainty
±0.25 V
0.01 mV
0.02% RDG + 0.1 mV
-3 ~ -0.25 V
0.1 mV
0.02% RDG + 0.1 mV
0.25 ~ 12 V
0.1 mV
0.02% RDG + 0.1 mV

features
parameter
temperature coefficient
< ±0.0015% RDG / ℃ outside of 18 ~ 28℃
< ±0.0008% RDG / ℉ outside of 64.4 ~ 82.4℉
Maximum load current
5 mA
Load impact
<50 µV/mA
selectable unit
V, mV, µV

mAproduce
mAproduce(source/receive) 0 ~ 25 mA
range
resolving power
1Annual uncertainty
0 ~ 25 mA
0.0001 mA
0.02% RDG + 1.5 µV

features
parameter
temperature coefficient
< ±0.0015% RDG / ℃ outside of 18 ~ 28℃
< ±0.0008% RDG / ℉ outside of 64.4 ~ 82.4℉
Maximum load impedance (source)
800 ohm (0 ~ 20 mA), 640 ohm (20 ~ 25 mA)
Maximum circuit voltage (receiving)
60 V
selectable unit
mA, µA

Resistance measurement
Resistance measurement0 ~ 4000 ohm
range
resolving power
1Annual uncertainty
0 ~ 250 ohm
250 ~ 2650 ohm
2650 ~ 4000 phm
1 mohm
10 mohm
100 mohm
4-wire system: 0.02% RDG+3.5 Mohm
3-wire system: 0.02% RDG+13.5 mohm

features
parameter
temperature coefficient
< ±0.0015% RDG / ℃ outside of 18 ~ 28℃
< ±0.0008% RDG / ℉ outside of 64.4 ~ 82.4℉
Measure current
Pulsed, bi-directional 1 mA (0..500 W), 0.2 mA (>500 W).
selectable unit
ohm, kohm
Display refresh rate
3/second

Resistance simulation
Resistance simulation0 ~ 4000 ohm
range
resolving power
1Annual uncertainty
0 ~ 400 ohm
10 mohm
0.04% RDG or 30 mohm (whichever is greater)
400 ~ 4000 ohm
100 mohm
0.04% RDG or 30 mohm (whichever is greater)

features
parameter
temperature coefficient
< ±0.0015% RDG / ℃ outside of 18 ~ 28℃
< ±0.0008% RDG / ℉ outside of 64.4 ~ 82.4℉
Maximum excitation current
5 mA (0 ~ 650 ohm)
Iexc × Rsim < 3.25 v (650 ~ 4000 ohm)
Set time (pulse current)
1 ms
selectable unit
ohm, kohm

Frequency generation
Frequency generation0.0005~ 10 000 Hz
range
resolving power
1Annual uncertainty
0.0005 ~ 0.5 Hz
0.000001 Hz
0.01% RDG
0.5 ~ 5 Hz
0.00001 Hz
0.01% RDG
5 ~ 50 Hz
0.0001 Hz
0.01% RDG
50 ~ 500 Hz
0.001 Hz
0.01% RDG
500 ~ 5000 Hz
0.01 Hz
0.01% RDG
5000 ~ 10000 Hz
0.1 Hz
0.01% RDG

features
parameter
temperature coefficient
Parameter temperature range: -10~50 ℃ (14~122 ℉)
Maximum load current
5 mA
Output amplitude positive square wave
0 ~ 12 Vpp ±(0.2 V + 5%)
Output amplitude symmetric square wave
0 ~ 6Vpp ±(0.2 V + 5%)
Duty cycle
1 ~ 99% (0.0009 ~ 500 Hz),
high / low time: min 25 µs, max 1165 s
selectable unit
Hz, kHz, cph, 1/Hz (s), 1/kHz (ms), 1/MH (µs)
Jitter
<0.28 µs

Pulse generation
Pulse generation
features
parameter
range
0~9999999 pulses
resolving power
1 pulse
Maximum load current
5 mA
Output amplitude positive pulse
0 ~ 12 Vpp ±(0.2 V + 5%)
Output amplitude symmetric pulse
0 ~ 6Vpp ±(0.2 V + 5%)
Pulse frequency
0.0005 ~ 10 000 Hz
Duty cycle
1 ~ 99 % (0.0009 ~ 500 Hz),
high / low time: min 25µs, max 1165 s

Temperature measurement and simulation
Thermocouple measurement and simulation
type
range()
range()
1Annual uncertainty
B
0 ~ 1820
0 ~ 200
200 ~ 500
500 ~ 800
800 ~ 1820
± 0.02% thermoelectric potential+4 µ V
2.0℃
0.6℃
0.8℃
R
-50 ~ 1768
-50 ~ 0
0 ~ 150
150 ~ 1400
1400 ~ 1768
1.0℃
0.7℃
0.5℃
0.6℃
S
-50 ~ 1768
-50 ~ 0
0 ~ 50
50 ~ 1500
1500 ~ 1768
1.0℃
0.7℃
0.6℃
0.7℃
E
-270 ~ 1000
-270 ~ -200
-200 ~ 0
0 ~ 600
600 ~ 1000
± 0.02% thermoelectric potential+4 µ V
0.08% RDG + 0.07℃
0.015% RDG + 0.07℃
0.026% RDG
J
-210 ~ 1200
-210 ~ -200
-200 ~ 0
0 ~ 1200
± 0.02% thermoelectric potential+4 µ V
0.07%RDG + 0.08℃
0.02% RDG + 0.08℃
K
-270 ~ 1372
-270 ~ -200
-200 ~ 0
0 ~ 1000
1000 ~ 1372
± 0.02% thermoelectric potential+4 µ V
0.1% RDG + 0.1℃
0.02% RDG + 0.1℃
0.03% RDG
N
-270 ~ 1300
-270 ~ -200
-200 ~ -100
-100 ~ 0
0 ~ 750
750 ~ 1300
± 0.02% thermoelectric potential+4 µ V
0.2% RDG
0.05% RDG + 0.15℃
,
0.01% RDG + , , 0.15℃
0.03% RDG
<, DIV align=center>T
-270 ~ 400
-270 ~ -250
-250 ~ -200
-200 ~ 0
0 ~ 400
± 0.02% thermoelectric potential+4 µ V
0.7℃
0.1% RDG + 0.1℃
0.01% RDG + 0.1℃
U
200 ~ 600
-200 ~ 0
0 ~ 600
0.1% RDG + 0.15℃
0.01% RDG + 0.15℃
L
-200 ~ 900
-200 ~ 0
0 ~ 900
0.07% RDG + 0.13℃
0.02% RDG + 0.13℃
C
0 ~ 2315
0 ~ 1000
1000 ~ 2000
2000 ~ 2315
0.4℃
0.8℃
1.2℃
G
0 ~ 2315
0 ~ 100
100 ~ 2315
± 0.02% thermoelectric potential+4 µ V
1.0℃
D
0 ~ 2315
0 ~ 1000
1000 ~ 2000
2000 ~ 2315
0.4℃
0.8℃
1.2℃

features
measure
simulation
resolving power
0.01℃
0.01℃
temperature coefficient
<± 0.0015% thermoelectric potential/℃ outside of 18~28 ℃
<± 0.0008% thermoelectric potential/℉ outside of 64.4~82.4 ℉
<± 0.0015% thermoelectric potential/℃ outside of 18~28 ℃
<± 0.0008% thermoelectric potential/℉ outside of 64.4~82.4 ℉
Input impedance
>10 Mohm
-
selectable unit
℃, ℉, K
℃, ℉, K
Display refresh rate
3/second
-
Maximum load current
-
5 mA
Load impact
-
< 5 µV/mA

Internal reference nodes
range()
1Annual uncertainty
-10 ~ 50℃
±0.25℃

RTDmeasure
Sensor type
range
resolving power
measure 1Annual uncertainty
Pt 50 ~ 1000
-200 ~ 200℃
200 ~ 600℃
600 ~ 850℃
0.01℃
0.01℃
0.01℃
0.1℃
0.2℃
0.3℃
Ni 100
-60 ~ 180℃
0.01℃
0.1℃
Ni 120
-80 ~ 260℃
0.01℃
0.1℃
Cu 10
-200 ~ 260℃
0.01℃
0.2℃

features
parameter
temperature coefficient
< ±0.0015% RDG / ℃ outside of 18 ~ 28℃
< ±0.0008% RDG / ℉ outside of 64.4 ~ 82.4℉
Measure current
Pulsed, 1 mA (0 ~ 500 ohm), 0.2 mA (>500 ohm)
selectable unit
℃, ℉, K
Display refresh rate
3/second

RTDsimulation
Sensor type
range
resolving power
simulation 1Annual uncertainty
Pt 50 ~ 1000
-200 ~ 200℃
200 ~ 600℃
600 ~ 850℃
0.01℃
0.01℃
0.01℃
0.15℃
0.25℃
0.35℃
Ni 100
-60 ~ 180℃
0.01℃
0.15℃
Ni 120
-80 ~ 260℃
0.01℃
0.15℃
Cu 10
-200 ~ 260℃
0.01℃
0.8℃

features
parameter
temperature coefficient
< ±0.0015% RDG / ℃ outside of 18 ~ 28℃
< ±0.0008% RDG / ℉ outside of 64.4 ~ 82.4℉
Maximum excitation current
5 mA (0 ~ 650 ohm)
Iexc × Rsim < 3.25 V (680 ~ 4000 ohm)
selectable unit
℃, ℉, K

standardRTDSensor type
Pt 50 (385)
Pt 500 (385)
Pt 100 (3926)
Ni 100 (618)
Pt 100 (385)
Pt 1000 (385)
Pt 100 (391)
<, DIV align=left>Ni 120 (672)
Pt 200 (385)
Pt 100 (375)
Cu 10 (427)
Pt 400 (385)
Pt 100 (3923)


Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!