Nanjing Kelunde Scientific Instrument Co., Ltd
Home>Products>InnuPure C16 touch fully automatic nucleic acid extractor
InnuPure C16 touch fully automatic nucleic acid extractor
The German Jena fully automatic nucleic acid extraction instrument InnuPure C16 touch can be used with both DC technology magnetic bead extraction kit
Product details

Classic Reshaping

InnuPure C16touchUsed itCyBioThe accuracy and precision of liquid handling in liquid transfer workstation productsInnuScreenPatent technology for nucleic acid extraction

InnuPure C16touchThe fully automatic nucleic acid extractor frees people from the tedious process of nucleic acid extraction and purification, greatly improving work efficiency and product quality. You just need to add the sample, select the corresponding extraction program, and press“start”You can easily obtain pure nucleic acid samples, which is a powerful helper for your nucleic acid research and testing work.

DC-Technologytechnology

2005Nian Jena Company invented patented nucleic acid extraction technologyDual Chemistry TechnologyDC-TechnologyThe double buffer technology uses a unique lysis buffer and a novel binding buffer, without the need for high concentration ionic salts. Compared with previous high ionic salt reagents, it has the following advantages:

n Provides mild reaction conditions and a more stable lysis environment, maximizing the efficiency of sample lysis and protein degradation, and improving the yield of nucleic acid extraction

n Provides a milder chemical environment, allowing nucleic acids to undergo less chemical cleavage, resulting in more complete nucleic acid fragments

n Low salt concentration buffer can effectively reducefollow-upThe cleaning steps save time

n The obtained nucleic acid can be directly used for downstream experiments and can be stored for a long time

Smart Extractiontechnology??New generation nucleic acid extraction technology

2016Nian Jena Company has invented a patented new generation of nucleic acid extraction technologySmart ExtractionThis technology breaks the traditional way of nucleic acid extraction kits relying on media to adsorb nucleic acids, and the extraction process does not require phenol/Chloroform, no need for ion exchange, no need for centrifuge columns, no need for silica gel membranes, no need for magnetic beads, justtipBlow up and down to complete. The extracted nucleic acid has high yield, good purity, simple operation, fast speed, and is easy to achieve automation. We now have supporting automation instruments from Jena CompanyInnuPure C16InnuPure C16touchInnuPure C96GeneTheatreCybio SELMACybio FeliXThe reagent kit will also be launched in the future to support other companies' pipetting workstations.


Efficient: Fully automated nucleic acid extractor

n Widely used?variousDNAandRNAExtraction kit. The fully automatic extraction kit includes motion/Plant tissue, cells, whole blood, swab samples, formalin fixed paraffin embedded tissue samples, bacteria, mycobacteria, feces, viruses, complex forensic samples, and deeply processed foods, etc., can be used simultaneouslycell-freeEnrichment and extraction of nucleic acids.

n Nucleic acid adsorption?Based on magnetic beads. High quality magnetic beads serve as solid media for binding with nucleic acids; A suitable buffer environment ensures that the magnetic beads are evenly dispersed in the solution; When multifunctional heating/Magnetic module(IHMU ? Intelligent Heating/Magnet Unit)Ascend to the reagent strip/At the bottom of the board, magnetic beads-The nucleic acid complex can quickly accumulate at the bottom of the tube, and the upper waste liquid is sucked out and transferred through the gun head. If adoptedSmart ExtractionThe reagent kit does not require magnetic bead adsorption.

n Integrated magnetic force/Heating plate?Collect magnetic beads and heat the sample. During sample lysis, ethanol evaporation, and nucleic acid elution, the heating module will heat up to the specified temperature. Residual substances (such as ethanol) are completely removed, and nucleic acid is eluted into the eluent. If there are residual impurities (such as ethanol, salts, etc.) in the nucleic acid product, it will inhibit downstream experiments (enzyme digestionPCRqPCREtc.).

n Patent technology? DCTechnology. All test kits use Jena's patented technologyDCTechnology that reduces salt ion concentration/Provide the optimal environment for protein hydrolysis while maintaining strength, reducing the residue of proteins and salts in nucleic acid products. This technology can greatly save extraction time and improve nucleic acid quality.



intelligence:Humanized reagent kit design

Pre installed sealing film reagent strip/Board, can be extracted simultaneously at once1-16A sample. All reagent kits are ready to use, making daily operations very simple and time-saving. The reagent kit does not require sub packaging, saving a lot of separation time and minimizing manual operation. Pre packaged reagents also avoid the possibility of incorrect addition that may occur during manual packaging/Leakage and contamination caused by excessive addition during the sampling process. At the same time, the reagent kit includes all the reagents required for extraction/Consumables and pre packaged reagents do not require additional purchase.

There are two packaging methods for the reagent kit: one is the reagent strip, which extracts one sample per strip, suitable for extracting single/small amounts of samples without wasting reagents/consumables; One type is a reagent plate, suitable for low to medium flux extraction, capable of extracting up to 16 samples at a time. The InnuPure C16 touch only requires you to place the reagent strip/plate on the sample tray, and the operation is very simple.


history:25More than years of experience in high-precision pipetting

The InnuPure C16 touch uses CyBio pipetting technology to ensure high precision and reproducibility of nucleic acid extraction process pipetting. At the same time, high-quality gun heads ensure very little liquid residue inside the gun heads.

The intelligent separation unit can set a wide elution volume of 20-500 μ l; The eluted nucleic acid is automatically transferred to the collection tube without the need for further transfer. The gun head and collection tube are both included in the extraction kit.


Reliability: Effectively avoiding cross contamination

InnuPure C16touchThe design concept and reagent packaging method minimize the possibility of cross contamination.

n Unique advantages:The perforation function of the pipette head avoids contamination between reagents caused by membrane tearing

n 1mlThe gun head with filter element avoids contamination between the pipette head and the sample

n Pre packaged sealed reagents avoid contamination during reagent packaging

n UVLamp sterilization effectively eliminates contamination of samples between batches

n The front door of the instrument is completely closed during operation, blocking external environmental pollution



Convenience:IPextractoperating system

The integrated 10 inch touch screen allows the InnuPure C16 touch to be operated independently without any external devices, saving experimental space.

The IPExtract software includes all extraction programs, eliminating the need for you to spend time exploring the program yourself, and providing lifelong free upgrades. Add the sample, select the corresponding program, and click start. If a large number of samples are extracted, especially in the diagnostic industry, the instrument can be connected to an external barcode scanner through a USB interface. Sample information can be imported for traceability, and the information of the reagent kit can also be scanned and recorded.